ABAP Select data from SAP table PVCON_DB into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP PVCON_DB table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to PVCON_DB. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the PVCON_DB table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_PVCON_DB TYPE STANDARD TABLE OF PVCON_DB,
      WA_PVCON_DB TYPE PVCON_DB,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: <PVCON_DB> TYPE PVCON_DB.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_PVCON_DB.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM PVCON_DB
  INTO TABLE IT_PVCON_DB.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM PVCON_DB
*  INTO TABLE @DATA(IT_PVCON_DB2).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_PVCON_DB INDEX 1 INTO DATA(WA_PVCON_DB2).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_PVCON_DB ASSIGNING <PVCON_DB>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
<PVCON_DB>-MANDT = 1.
<PVCON_DB>-PVGUID = 1.
<PVCON_DB>-PVCNT = 1.
<PVCON_DB>-ACTIVE = 1.
<PVCON_DB>-CMPID = 1.
ENDLOOP.

LOOP AT IT_PVCON_DB INTO WA_PVCON_DB.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_PVCON_DB-QUANT, sy-vline,
WA_PVCON_DB-QUNIT, sy-vline,
WA_PVCON_DB-DOCID, sy-vline,
WA_PVCON_DB-DMUCNT, sy-vline,
WA_PVCON_DB-ROMS1, sy-vline,
WA_PVCON_DB-PRCNT1, sy-vline.
ENDLOOP. *Add any further fields from structure WA_PVCON_DB you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_PVCON_DB TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_PVCON_DB INTO WA_PVCON_DB. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.

*Conversion exit CUNIT, internal->external for field QUNIT CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_PVCON_DB-QUNIT IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_PVCON_DB-QUNIT.
WRITE:/ 'New Value:', ld_input.

*Conversion exit CUNIT, internal->external for field ROMEI CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_PVCON_DB-ROMEI IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_PVCON_DB-ROMEI.
WRITE:/ 'New Value:', ld_input.

*Conversion exit CUNIT, internal->external for field ROKME CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_PVCON_DB-ROKME IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_PVCON_DB-ROKME.
WRITE:/ 'New Value:', ld_input.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_PVCON_DB_STR,
MANDT TYPE STRING,
PVGUID TYPE STRING,
PVCNT TYPE STRING,
ACTIVE TYPE STRING,
CMPID TYPE STRING,
QUANT TYPE STRING,
QUNIT TYPE STRING,
DOCID TYPE STRING,
DMUCNT TYPE STRING,
ROMS1 TYPE STRING,
PRCNT1 TYPE STRING,
ROMS2 TYPE STRING,
PRCNT2 TYPE STRING,
ROMS3 TYPE STRING,
PRCNT3 TYPE STRING,
ROMEI TYPE STRING,
ROMEN TYPE STRING,
ROKME TYPE STRING,
RFORM TYPE STRING,
DBOP TYPE STRING,END OF T_EKKO_STR. DATA: WA_PVCON_DB_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_PVCON_DB_STR-MANDT sy-vline
WA_PVCON_DB_STR-PVGUID sy-vline
WA_PVCON_DB_STR-PVCNT sy-vline
WA_PVCON_DB_STR-ACTIVE sy-vline
WA_PVCON_DB_STR-CMPID sy-vline
WA_PVCON_DB_STR-QUANT sy-vline
WA_PVCON_DB_STR-QUNIT sy-vline
WA_PVCON_DB_STR-DOCID sy-vline
WA_PVCON_DB_STR-DMUCNT sy-vline
WA_PVCON_DB_STR-ROMS1 sy-vline
WA_PVCON_DB_STR-PRCNT1 sy-vline
WA_PVCON_DB_STR-ROMS2 sy-vline
WA_PVCON_DB_STR-PRCNT2 sy-vline
WA_PVCON_DB_STR-ROMS3 sy-vline
WA_PVCON_DB_STR-PRCNT3 sy-vline
WA_PVCON_DB_STR-ROMEI sy-vline
WA_PVCON_DB_STR-ROMEN sy-vline
WA_PVCON_DB_STR-ROKME sy-vline
WA_PVCON_DB_STR-RFORM sy-vline
WA_PVCON_DB_STR-DBOP sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.