ABAP Select data from SAP table PTH_HTHCTXF1D_DATA into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP PTH_HTHCTXF1D_DATA table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to PTH_HTHCTXF1D_DATA. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the PTH_HTHCTXF1D_DATA table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_PTH_HTHCTXF1D_DATA TYPE STANDARD TABLE OF PTH_HTHCTXF1D_DATA,
      WA_PTH_HTHCTXF1D_DATA TYPE PTH_HTHCTXF1D_DATA,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: <PTH_HTHCTXF1D_DATA> TYPE PTH_HTHCTXF1D_DATA.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_PTH_HTHCTXF1D_DATA.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM PTH_HTHCTXF1D_DATA
  INTO TABLE IT_PTH_HTHCTXF1D_DATA.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM PTH_HTHCTXF1D_DATA
*  INTO TABLE @DATA(IT_PTH_HTHCTXF1D_DATA2).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_PTH_HTHCTXF1D_DATA INDEX 1 INTO DATA(WA_PTH_HTHCTXF1D_DATA2).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_PTH_HTHCTXF1D_DATA ASSIGNING <PTH_HTHCTXF1D_DATA>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
<PTH_HTHCTXF1D_DATA>-RVC_ER_TAXID = 1.
<PTH_HTHCTXF1D_DATA>-TAX_TYP1 = 1.
<PTH_HTHCTXF1D_DATA>-TAX_TYP2 = 1.
<PTH_HTHCTXF1D_DATA>-TAX_TYP3 = 1.
<PTH_HTHCTXF1D_DATA>-TAX_TYP4 = 1.
ENDLOOP.

LOOP AT IT_PTH_HTHCTXF1D_DATA INTO WA_PTH_HTHCTXF1D_DATA.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_PTH_HTHCTXF1D_DATA-RVC_ER_TAX_BRANCHNO, sy-vline,
WA_PTH_HTHCTXF1D_DATA-PAGENO, sy-vline,
WA_PTH_HTHCTXF1D_DATA-TPAGENO, sy-vline,
WA_PTH_HTHCTXF1D_DATA-DT_TBL, sy-vline,
WA_PTH_HTHCTXF1D_DATA-RVC_PTOTAL_INCOME_BAHT, sy-vline,
WA_PTH_HTHCTXF1D_DATA-RVC_PTOTAL_INCOME_STANG, sy-vline.
ENDLOOP. *Add any further fields from structure WA_PTH_HTHCTXF1D_DATA you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_PTH_HTHCTXF1D_DATA TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_PTH_HTHCTXF1D_DATA INTO WA_PTH_HTHCTXF1D_DATA. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_PTH_HTHCTXF1D_DATA_STR,
RVC_ER_TAXID TYPE STRING,
TAX_TYP1 TYPE STRING,
TAX_TYP2 TYPE STRING,
TAX_TYP3 TYPE STRING,
TAX_TYP4 TYPE STRING,
RVC_ER_TAX_BRANCHNO TYPE STRING,
PAGENO TYPE STRING,
TPAGENO TYPE STRING,
DT_TBL TYPE STRING,
RVC_PTOTAL_INCOME_BAHT TYPE STRING,
RVC_PTOTAL_INCOME_STANG TYPE STRING,
RVC_PTOTAL_TAX_BAHT TYPE STRING,
RVC_PTOTAL_TAX_STANG TYPE STRING,
RVC_AUPR TYPE STRING,
RVC_POSN TYPE STRING,
RVC_PAYDT_D TYPE STRING,
RVC_PAYDT_M TYPE STRING,
RVC_PAYDT_Y TYPE STRING,
TAXID01 TYPE STRING,
TAXID02 TYPE STRING,
TAXID03 TYPE STRING,
TAXID04 TYPE STRING,
TAXID05 TYPE STRING,
TAXID06 TYPE STRING,
TAXID07 TYPE STRING,
TAXID08 TYPE STRING,
TAXID09 TYPE STRING,
TAXID10 TYPE STRING,
TAXID11 TYPE STRING,
TAXID12 TYPE STRING,
TAXID13 TYPE STRING,
BRANCHNO01 TYPE STRING,
BRANCHNO02 TYPE STRING,
BRANCHNO03 TYPE STRING,
BRANCHNO04 TYPE STRING,
BRANCHNO05 TYPE STRING,
MODTX TYPE STRING,END OF T_EKKO_STR. DATA: WA_PTH_HTHCTXF1D_DATA_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_PTH_HTHCTXF1D_DATA_STR-RVC_ER_TAXID sy-vline
WA_PTH_HTHCTXF1D_DATA_STR-TAX_TYP1 sy-vline
WA_PTH_HTHCTXF1D_DATA_STR-TAX_TYP2 sy-vline
WA_PTH_HTHCTXF1D_DATA_STR-TAX_TYP3 sy-vline
WA_PTH_HTHCTXF1D_DATA_STR-TAX_TYP4 sy-vline
WA_PTH_HTHCTXF1D_DATA_STR-RVC_ER_TAX_BRANCHNO sy-vline
WA_PTH_HTHCTXF1D_DATA_STR-PAGENO sy-vline
WA_PTH_HTHCTXF1D_DATA_STR-TPAGENO sy-vline
WA_PTH_HTHCTXF1D_DATA_STR-DT_TBL sy-vline
WA_PTH_HTHCTXF1D_DATA_STR-RVC_PTOTAL_INCOME_BAHT sy-vline
WA_PTH_HTHCTXF1D_DATA_STR-RVC_PTOTAL_INCOME_STANG sy-vline
WA_PTH_HTHCTXF1D_DATA_STR-RVC_PTOTAL_TAX_BAHT sy-vline
WA_PTH_HTHCTXF1D_DATA_STR-RVC_PTOTAL_TAX_STANG sy-vline
WA_PTH_HTHCTXF1D_DATA_STR-RVC_AUPR sy-vline
WA_PTH_HTHCTXF1D_DATA_STR-RVC_POSN sy-vline
WA_PTH_HTHCTXF1D_DATA_STR-RVC_PAYDT_D sy-vline
WA_PTH_HTHCTXF1D_DATA_STR-RVC_PAYDT_M sy-vline
WA_PTH_HTHCTXF1D_DATA_STR-RVC_PAYDT_Y sy-vline
WA_PTH_HTHCTXF1D_DATA_STR-TAXID01 sy-vline
WA_PTH_HTHCTXF1D_DATA_STR-TAXID02 sy-vline
WA_PTH_HTHCTXF1D_DATA_STR-TAXID03 sy-vline
WA_PTH_HTHCTXF1D_DATA_STR-TAXID04 sy-vline
WA_PTH_HTHCTXF1D_DATA_STR-TAXID05 sy-vline
WA_PTH_HTHCTXF1D_DATA_STR-TAXID06 sy-vline
WA_PTH_HTHCTXF1D_DATA_STR-TAXID07 sy-vline
WA_PTH_HTHCTXF1D_DATA_STR-TAXID08 sy-vline
WA_PTH_HTHCTXF1D_DATA_STR-TAXID09 sy-vline
WA_PTH_HTHCTXF1D_DATA_STR-TAXID10 sy-vline
WA_PTH_HTHCTXF1D_DATA_STR-TAXID11 sy-vline
WA_PTH_HTHCTXF1D_DATA_STR-TAXID12 sy-vline
WA_PTH_HTHCTXF1D_DATA_STR-TAXID13 sy-vline
WA_PTH_HTHCTXF1D_DATA_STR-BRANCHNO01 sy-vline
WA_PTH_HTHCTXF1D_DATA_STR-BRANCHNO02 sy-vline
WA_PTH_HTHCTXF1D_DATA_STR-BRANCHNO03 sy-vline
WA_PTH_HTHCTXF1D_DATA_STR-BRANCHNO04 sy-vline
WA_PTH_HTHCTXF1D_DATA_STR-BRANCHNO05 sy-vline
WA_PTH_HTHCTXF1D_DATA_STR-MODTX sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.