ABAP Select data from SAP table PTH_HTHCTXF1C_DATA into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP PTH_HTHCTXF1C_DATA table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to PTH_HTHCTXF1C_DATA. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the PTH_HTHCTXF1C_DATA table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_PTH_HTHCTXF1C_DATA TYPE STANDARD TABLE OF PTH_HTHCTXF1C_DATA,
      WA_PTH_HTHCTXF1C_DATA TYPE PTH_HTHCTXF1C_DATA,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: <PTH_HTHCTXF1C_DATA> TYPE PTH_HTHCTXF1C_DATA.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_PTH_HTHCTXF1C_DATA.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM PTH_HTHCTXF1C_DATA
  INTO TABLE IT_PTH_HTHCTXF1C_DATA.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM PTH_HTHCTXF1C_DATA
*  INTO TABLE @DATA(IT_PTH_HTHCTXF1C_DATA2).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_PTH_HTHCTXF1C_DATA INDEX 1 INTO DATA(WA_PTH_HTHCTXF1C_DATA2).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_PTH_HTHCTXF1C_DATA ASSIGNING <PTH_HTHCTXF1C_DATA>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
<PTH_HTHCTXF1C_DATA>-ER_TAXID = 1.
<PTH_HTHCTXF1C_DATA>-BRCOD = 1.
<PTH_HTHCTXF1C_DATA>-ADDRESS0 = 1.
<PTH_HTHCTXF1C_DATA>-ADDRESS1 = 1.
<PTH_HTHCTXF1C_DATA>-ADDRESS2 = 1.
ENDLOOP.

LOOP AT IT_PTH_HTHCTXF1C_DATA INTO WA_PTH_HTHCTXF1C_DATA.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_PTH_HTHCTXF1C_DATA-ADDRESS3, sy-vline,
WA_PTH_HTHCTXF1C_DATA-ADDRESS4, sy-vline,
WA_PTH_HTHCTXF1C_DATA-ADDRESS5, sy-vline,
WA_PTH_HTHCTXF1C_DATA-ADDRESS6, sy-vline,
WA_PTH_HTHCTXF1C_DATA-ADDRESS7, sy-vline,
WA_PTH_HTHCTXF1C_DATA-ADDRESS8, sy-vline.
ENDLOOP. *Add any further fields from structure WA_PTH_HTHCTXF1C_DATA you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_PTH_HTHCTXF1C_DATA TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_PTH_HTHCTXF1C_DATA INTO WA_PTH_HTHCTXF1C_DATA. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_PTH_HTHCTXF1C_DATA_STR,
ER_TAXID TYPE STRING,
BRCOD TYPE STRING,
ADDRESS0 TYPE STRING,
ADDRESS1 TYPE STRING,
ADDRESS2 TYPE STRING,
ADDRESS3 TYPE STRING,
ADDRESS4 TYPE STRING,
ADDRESS5 TYPE STRING,
ADDRESS6 TYPE STRING,
ADDRESS7 TYPE STRING,
ADDRESS8 TYPE STRING,
ADDRESS9 TYPE STRING,
ADDRESS10 TYPE STRING,
ADDRESS11 TYPE STRING,
ADDRESS12 TYPE STRING,
ADDRESS13 TYPE STRING,
BE_YEAR TYPE STRING,
MNTH TYPE STRING,
COUNT_PAGES_C TYPE STRING,
TOT_EMP_401_PROG TYPE STRING,
TOT_INCOME_401_PROG_BAHT TYPE STRING,
TOT_INCOME_401_PROG_STG TYPE STRING,
TOT_TAX_401_PROG_BAHT TYPE STRING,
TOT_TAX_401_PROG_STG TYPE STRING,
TOT_EMP_4012_TERM TYPE STRING,
TOT_INCOME_4012_TERM_BAHT TYPE STRING,
TOT_INCOME_4012_TERM_STG TYPE STRING,
TOT_TAX_4012_TERM_BAHT TYPE STRING,
TOT_TAX_4012_TERM_STG TYPE STRING,
TOT_EMP_402_IN_THAI TYPE STRING,
TOT_INCOME_402_IN_THAI_BAHT TYPE STRING,
TOT_INCOME_402_IN_THAI_STG TYPE STRING,
TOT_TAX_402_IN_THAI_BAHT TYPE STRING,
TOT_TAX_402_IN_THAI_STG TYPE STRING,
TOT_EMP_402_NOT_THAI TYPE STRING,
TOT_INCOME_402_NOT_THAI_BAHT TYPE STRING,
TOT_INCOME_402_NOT_THAI_STG TYPE STRING,
TOT_TAX_402_NOT_THAI_BAHT TYPE STRING,
TOT_TAX_402_NOT_THAI_STG TYPE STRING,
TOT_EMP TYPE STRING,
TOT_INCOME_BAHT_C TYPE STRING,
TOT_INCOME_STG_C TYPE STRING,
TOT_TAX_BAHT_C TYPE STRING,
TOT_TAX_STG_C TYPE STRING,
RVC_AUPR TYPE STRING,
RVC_POSN TYPE STRING,
RVD_PAYDT_D TYPE STRING,
RVD_PAYDT_M TYPE STRING,
RVD_PAYDT_Y TYPE STRING,
PRINT_DETAIL_FLAG1 TYPE STRING,
PRINT_DETAIL_FLAG2 TYPE STRING,
MODTX TYPE STRING,END OF T_EKKO_STR. DATA: WA_PTH_HTHCTXF1C_DATA_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_PTH_HTHCTXF1C_DATA_STR-ER_TAXID sy-vline
WA_PTH_HTHCTXF1C_DATA_STR-BRCOD sy-vline
WA_PTH_HTHCTXF1C_DATA_STR-ADDRESS0 sy-vline
WA_PTH_HTHCTXF1C_DATA_STR-ADDRESS1 sy-vline
WA_PTH_HTHCTXF1C_DATA_STR-ADDRESS2 sy-vline
WA_PTH_HTHCTXF1C_DATA_STR-ADDRESS3 sy-vline
WA_PTH_HTHCTXF1C_DATA_STR-ADDRESS4 sy-vline
WA_PTH_HTHCTXF1C_DATA_STR-ADDRESS5 sy-vline
WA_PTH_HTHCTXF1C_DATA_STR-ADDRESS6 sy-vline
WA_PTH_HTHCTXF1C_DATA_STR-ADDRESS7 sy-vline
WA_PTH_HTHCTXF1C_DATA_STR-ADDRESS8 sy-vline
WA_PTH_HTHCTXF1C_DATA_STR-ADDRESS9 sy-vline
WA_PTH_HTHCTXF1C_DATA_STR-ADDRESS10 sy-vline
WA_PTH_HTHCTXF1C_DATA_STR-ADDRESS11 sy-vline
WA_PTH_HTHCTXF1C_DATA_STR-ADDRESS12 sy-vline
WA_PTH_HTHCTXF1C_DATA_STR-ADDRESS13 sy-vline
WA_PTH_HTHCTXF1C_DATA_STR-BE_YEAR sy-vline
WA_PTH_HTHCTXF1C_DATA_STR-MNTH sy-vline
WA_PTH_HTHCTXF1C_DATA_STR-COUNT_PAGES_C sy-vline
WA_PTH_HTHCTXF1C_DATA_STR-TOT_EMP_401_PROG sy-vline
WA_PTH_HTHCTXF1C_DATA_STR-TOT_INCOME_401_PROG_BAHT sy-vline
WA_PTH_HTHCTXF1C_DATA_STR-TOT_INCOME_401_PROG_STG sy-vline
WA_PTH_HTHCTXF1C_DATA_STR-TOT_TAX_401_PROG_BAHT sy-vline
WA_PTH_HTHCTXF1C_DATA_STR-TOT_TAX_401_PROG_STG sy-vline
WA_PTH_HTHCTXF1C_DATA_STR-TOT_EMP_4012_TERM sy-vline
WA_PTH_HTHCTXF1C_DATA_STR-TOT_INCOME_4012_TERM_BAHT sy-vline
WA_PTH_HTHCTXF1C_DATA_STR-TOT_INCOME_4012_TERM_STG sy-vline
WA_PTH_HTHCTXF1C_DATA_STR-TOT_TAX_4012_TERM_BAHT sy-vline
WA_PTH_HTHCTXF1C_DATA_STR-TOT_TAX_4012_TERM_STG sy-vline
WA_PTH_HTHCTXF1C_DATA_STR-TOT_EMP_402_IN_THAI sy-vline
WA_PTH_HTHCTXF1C_DATA_STR-TOT_INCOME_402_IN_THAI_BAHT sy-vline
WA_PTH_HTHCTXF1C_DATA_STR-TOT_INCOME_402_IN_THAI_STG sy-vline
WA_PTH_HTHCTXF1C_DATA_STR-TOT_TAX_402_IN_THAI_BAHT sy-vline
WA_PTH_HTHCTXF1C_DATA_STR-TOT_TAX_402_IN_THAI_STG sy-vline
WA_PTH_HTHCTXF1C_DATA_STR-TOT_EMP_402_NOT_THAI sy-vline
WA_PTH_HTHCTXF1C_DATA_STR-TOT_INCOME_402_NOT_THAI_BAHT sy-vline
WA_PTH_HTHCTXF1C_DATA_STR-TOT_INCOME_402_NOT_THAI_STG sy-vline
WA_PTH_HTHCTXF1C_DATA_STR-TOT_TAX_402_NOT_THAI_BAHT sy-vline
WA_PTH_HTHCTXF1C_DATA_STR-TOT_TAX_402_NOT_THAI_STG sy-vline
WA_PTH_HTHCTXF1C_DATA_STR-TOT_EMP sy-vline
WA_PTH_HTHCTXF1C_DATA_STR-TOT_INCOME_BAHT_C sy-vline
WA_PTH_HTHCTXF1C_DATA_STR-TOT_INCOME_STG_C sy-vline
WA_PTH_HTHCTXF1C_DATA_STR-TOT_TAX_BAHT_C sy-vline
WA_PTH_HTHCTXF1C_DATA_STR-TOT_TAX_STG_C sy-vline
WA_PTH_HTHCTXF1C_DATA_STR-RVC_AUPR sy-vline
WA_PTH_HTHCTXF1C_DATA_STR-RVC_POSN sy-vline
WA_PTH_HTHCTXF1C_DATA_STR-RVD_PAYDT_D sy-vline
WA_PTH_HTHCTXF1C_DATA_STR-RVD_PAYDT_M sy-vline
WA_PTH_HTHCTXF1C_DATA_STR-RVD_PAYDT_Y sy-vline
WA_PTH_HTHCTXF1C_DATA_STR-PRINT_DETAIL_FLAG1 sy-vline
WA_PTH_HTHCTXF1C_DATA_STR-PRINT_DETAIL_FLAG2 sy-vline
WA_PTH_HTHCTXF1C_DATA_STR-MODTX sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.