ABAP Select data from SAP table PTCOR_TCONSTR into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP PTCOR_TCONSTR table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to PTCOR_TCONSTR. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the PTCOR_TCONSTR table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_PTCOR_TCONSTR TYPE STANDARD TABLE OF PTCOR_TCONSTR,
      WA_PTCOR_TCONSTR TYPE PTCOR_TCONSTR,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: <PTCOR_TCONSTR> TYPE PTCOR_TCONSTR.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_PTCOR_TCONSTR.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM PTCOR_TCONSTR
  INTO TABLE IT_PTCOR_TCONSTR.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM PTCOR_TCONSTR
*  INTO TABLE @DATA(IT_PTCOR_TCONSTR2).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_PTCOR_TCONSTR INDEX 1 INTO DATA(WA_PTCOR_TCONSTR2).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_PTCOR_TCONSTR ASSIGNING <PTCOR_TCONSTR>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
<PTCOR_TCONSTR>-WEBMO = 1.
<PTCOR_TCONSTR>-ENDDA = 1.
<PTCOR_TCONSTR>-BEGDA = 1.
<PTCOR_TCONSTR>-PERIODTYPE = 1.
<PTCOR_TCONSTR>-ARQ_POSS_SNC_DEF = 1.
ENDLOOP.

LOOP AT IT_PTCOR_TCONSTR INTO WA_PTCOR_TCONSTR.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_PTCOR_TCONSTR-ARQ_POSS_SNC, sy-vline,
WA_PTCOR_TCONSTR-UNIT_ARQ_POS_SNC, sy-vline,
WA_PTCOR_TCONSTR-PRMO_ARQ_POS_SNC, sy-vline,
WA_PTCOR_TCONSTR-ARQ_POSS_TIL_DEF, sy-vline,
WA_PTCOR_TCONSTR-ARQ_POSS_TIL, sy-vline,
WA_PTCOR_TCONSTR-UNIT_ARQ_POS_TIL, sy-vline.
ENDLOOP. *Add any further fields from structure WA_PTCOR_TCONSTR you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_PTCOR_TCONSTR TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_PTCOR_TCONSTR INTO WA_PTCOR_TCONSTR. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_PTCOR_TCONSTR_STR,
WEBMO TYPE STRING,
ENDDA TYPE STRING,
BEGDA TYPE STRING,
PERIODTYPE TYPE STRING,
ARQ_POSS_SNC_DEF TYPE STRING,
ARQ_POSS_SNC TYPE STRING,
UNIT_ARQ_POS_SNC TYPE STRING,
PRMO_ARQ_POS_SNC TYPE STRING,
ARQ_POSS_TIL_DEF TYPE STRING,
ARQ_POSS_TIL TYPE STRING,
UNIT_ARQ_POS_TIL TYPE STRING,
PRMO_ARQ_POS_TIL TYPE STRING,
MESS_BEFORE TYPE STRING,
MESS_AFTER TYPE STRING,
UNIT_MESS TYPE STRING,
PAST_TIME_LIMIT TYPE STRING,
PAST_TIME_QTY TYPE STRING,
PAST_TIME_UNIT TYPE STRING,
CURR_FORBID TYPE STRING,
DAY_WITH_MSG TYPE STRING,
ADJACENT_DAYS TYPE STRING,END OF T_EKKO_STR. DATA: WA_PTCOR_TCONSTR_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_PTCOR_TCONSTR_STR-WEBMO sy-vline
WA_PTCOR_TCONSTR_STR-ENDDA sy-vline
WA_PTCOR_TCONSTR_STR-BEGDA sy-vline
WA_PTCOR_TCONSTR_STR-PERIODTYPE sy-vline
WA_PTCOR_TCONSTR_STR-ARQ_POSS_SNC_DEF sy-vline
WA_PTCOR_TCONSTR_STR-ARQ_POSS_SNC sy-vline
WA_PTCOR_TCONSTR_STR-UNIT_ARQ_POS_SNC sy-vline
WA_PTCOR_TCONSTR_STR-PRMO_ARQ_POS_SNC sy-vline
WA_PTCOR_TCONSTR_STR-ARQ_POSS_TIL_DEF sy-vline
WA_PTCOR_TCONSTR_STR-ARQ_POSS_TIL sy-vline
WA_PTCOR_TCONSTR_STR-UNIT_ARQ_POS_TIL sy-vline
WA_PTCOR_TCONSTR_STR-PRMO_ARQ_POS_TIL sy-vline
WA_PTCOR_TCONSTR_STR-MESS_BEFORE sy-vline
WA_PTCOR_TCONSTR_STR-MESS_AFTER sy-vline
WA_PTCOR_TCONSTR_STR-UNIT_MESS sy-vline
WA_PTCOR_TCONSTR_STR-PAST_TIME_LIMIT sy-vline
WA_PTCOR_TCONSTR_STR-PAST_TIME_QTY sy-vline
WA_PTCOR_TCONSTR_STR-PAST_TIME_UNIT sy-vline
WA_PTCOR_TCONSTR_STR-CURR_FORBID sy-vline
WA_PTCOR_TCONSTR_STR-DAY_WITH_MSG sy-vline
WA_PTCOR_TCONSTR_STR-ADJACENT_DAYS sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.