ABAP Select data from SAP table PT1716 into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP PT1716 table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to PT1716. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the PT1716 table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_PT1716 TYPE STANDARD TABLE OF PT1716,
      WA_PT1716 TYPE PT1716,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: <PT1716> TYPE PT1716.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_PT1716.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM PT1716
  INTO TABLE IT_PT1716.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM PT1716
*  INTO TABLE @DATA(IT_PT17162).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_PT1716 INDEX 1 INTO DATA(WA_PT17162).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_PT1716 ASSIGNING <PT1716>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
<PT1716>-BEGUZ = 1.
<PT1716>-ENDUZ = 1.
<PT1716>-MONDAY = 1.
<PT1716>-TUESDAY = 1.
<PT1716>-WEDNESDAY = 1.
ENDLOOP.

LOOP AT IT_PT1716 INTO WA_PT1716.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_PT1716-THURSDAY, sy-vline,
WA_PT1716-FRIDAY, sy-vline,
WA_PT1716-SATURDAY, sy-vline,
WA_PT1716-SUNDAY, sy-vline,
WA_PT1716-SAWEEKS, sy-vline,
WA_PT1716-EAWEEKS, sy-vline.
ENDLOOP. *Add any further fields from structure WA_PT1716 you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_PT1716 TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_PT1716 INTO WA_PT1716. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_PT1716_STR,
BEGUZ TYPE STRING,
ENDUZ TYPE STRING,
MONDAY TYPE STRING,
TUESDAY TYPE STRING,
WEDNESDAY TYPE STRING,
THURSDAY TYPE STRING,
FRIDAY TYPE STRING,
SATURDAY TYPE STRING,
SUNDAY TYPE STRING,
SAWEEKS TYPE STRING,
EAWEEKS TYPE STRING,
SCHEDELEBEG TYPE STRING,
SCHEDELEEND TYPE STRING,
XDATES TYPE STRING,
RECFRQ TYPE STRING,
RECINT TYPE STRING,
X_WEEKS TYPE STRING,
X_MONTHS TYPE STRING,
OIMONTH TYPE STRING,
ROOM_OBJID TYPE STRING,
ROOM_RETID TYPE STRING,
INSTR_OTYPE TYPE STRING,
INSTR_OBJID TYPE STRING,
INSTR_RETID TYPE STRING,
INSTR_PROZT TYPE STRING,END OF T_EKKO_STR. DATA: WA_PT1716_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_PT1716_STR-BEGUZ sy-vline
WA_PT1716_STR-ENDUZ sy-vline
WA_PT1716_STR-MONDAY sy-vline
WA_PT1716_STR-TUESDAY sy-vline
WA_PT1716_STR-WEDNESDAY sy-vline
WA_PT1716_STR-THURSDAY sy-vline
WA_PT1716_STR-FRIDAY sy-vline
WA_PT1716_STR-SATURDAY sy-vline
WA_PT1716_STR-SUNDAY sy-vline
WA_PT1716_STR-SAWEEKS sy-vline
WA_PT1716_STR-EAWEEKS sy-vline
WA_PT1716_STR-SCHEDELEBEG sy-vline
WA_PT1716_STR-SCHEDELEEND sy-vline
WA_PT1716_STR-XDATES sy-vline
WA_PT1716_STR-RECFRQ sy-vline
WA_PT1716_STR-RECINT sy-vline
WA_PT1716_STR-X_WEEKS sy-vline
WA_PT1716_STR-X_MONTHS sy-vline
WA_PT1716_STR-OIMONTH sy-vline
WA_PT1716_STR-ROOM_OBJID sy-vline
WA_PT1716_STR-ROOM_RETID sy-vline
WA_PT1716_STR-INSTR_OTYPE sy-vline
WA_PT1716_STR-INSTR_OBJID sy-vline
WA_PT1716_STR-INSTR_RETID sy-vline
WA_PT1716_STR-INSTR_PROZT sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.