ABAP Select data from SAP table PSUBASGDSFTY into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP PSUBASGDSFTY table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to PSUBASGDSFTY. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the PSUBASGDSFTY table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_PSUBASGDSFTY TYPE STANDARD TABLE OF PSUBASGDSFTY,
      WA_PSUBASGDSFTY TYPE PSUBASGDSFTY,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: <PSUBASGDSFTY> TYPE PSUBASGDSFTY.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_PSUBASGDSFTY.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM PSUBASGDSFTY
  INTO TABLE IT_PSUBASGDSFTY.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM PSUBASGDSFTY
*  INTO TABLE @DATA(IT_PSUBASGDSFTY2).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_PSUBASGDSFTY INDEX 1 INTO DATA(WA_PSUBASGDSFTY2).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_PSUBASGDSFTY ASSIGNING <PSUBASGDSFTY>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
<PSUBASGDSFTY>-MANDT = 1.
<PSUBASGDSFTY>-SUBSTANCEUUID = 1.
<PSUBASGDSFTY>-PCPRPTYROOTTYPE = 1.
<PSUBASGDSFTY>-PCPRPTYINPROCESSUUID = 1.
<PSUBASGDSFTY>-PCPRPTYINPROCPROCGSTS = 1.
ENDLOOP.

LOOP AT IT_PSUBASGDSFTY INTO WA_PSUBASGDSFTY.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_PSUBASGDSFTY-PCPRPTYINPROCISACTIVE, sy-vline,
WA_PSUBASGDSFTY-PCPRPTYRELEASEDUUID, sy-vline,
WA_PSUBASGDSFTY-PCPRPTYRELDPROCGSTS, sy-vline,
WA_PSUBASGDSFTY-PCPRPTYRELDISACTIVE, sy-vline,
WA_PSUBASGDSFTY-RESPONSIBLEUNIT, sy-vline,
WA_PSUBASGDSFTY-PCPRPTYNAVGNLINKUUID, sy-vline.
ENDLOOP. *Add any further fields from structure WA_PSUBASGDSFTY you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_PSUBASGDSFTY TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_PSUBASGDSFTY INTO WA_PSUBASGDSFTY. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_PSUBASGDSFTY_STR,
MANDT TYPE STRING,
SUBSTANCEUUID TYPE STRING,
PCPRPTYROOTTYPE TYPE STRING,
PCPRPTYINPROCESSUUID TYPE STRING,
PCPRPTYINPROCPROCGSTS TYPE STRING,
PCPRPTYINPROCISACTIVE TYPE STRING,
PCPRPTYRELEASEDUUID TYPE STRING,
PCPRPTYRELDPROCGSTS TYPE STRING,
PCPRPTYRELDISACTIVE TYPE STRING,
RESPONSIBLEUNIT TYPE STRING,
PCPRPTYNAVGNLINKUUID TYPE STRING,
PCPRPTYISACTIVE TYPE STRING,END OF T_EKKO_STR. DATA: WA_PSUBASGDSFTY_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_PSUBASGDSFTY_STR-MANDT sy-vline
WA_PSUBASGDSFTY_STR-SUBSTANCEUUID sy-vline
WA_PSUBASGDSFTY_STR-PCPRPTYROOTTYPE sy-vline
WA_PSUBASGDSFTY_STR-PCPRPTYINPROCESSUUID sy-vline
WA_PSUBASGDSFTY_STR-PCPRPTYINPROCPROCGSTS sy-vline
WA_PSUBASGDSFTY_STR-PCPRPTYINPROCISACTIVE sy-vline
WA_PSUBASGDSFTY_STR-PCPRPTYRELEASEDUUID sy-vline
WA_PSUBASGDSFTY_STR-PCPRPTYRELDPROCGSTS sy-vline
WA_PSUBASGDSFTY_STR-PCPRPTYRELDISACTIVE sy-vline
WA_PSUBASGDSFTY_STR-RESPONSIBLEUNIT sy-vline
WA_PSUBASGDSFTY_STR-PCPRPTYNAVGNLINKUUID sy-vline
WA_PSUBASGDSFTY_STR-PCPRPTYISACTIVE sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.