ABAP Select data from SAP table PSEISPRTE into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP PSEISPRTE table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to PSEISPRTE. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the PSEISPRTE table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_PSEISPRTE TYPE STANDARD TABLE OF PSEISPRTE,
      WA_PSEISPRTE TYPE PSEISPRTE,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: <PSEISPRTE> TYPE PSEISPRTE.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_PSEISPRTE.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM PSEISPRTE
  INTO TABLE IT_PSEISPRTE.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM PSEISPRTE
*  INTO TABLE @DATA(IT_PSEISPRTE2).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_PSEISPRTE INDEX 1 INTO DATA(WA_PSEISPRTE2).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_PSEISPRTE ASSIGNING <PSEISPRTE>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
<PSEISPRTE>-MANDT = 1.
<PSEISPRTE>-POSNR = 1.
<PSEISPRTE>-PSPHI = 1.
<PSEISPRTE>-PSTRT = 1.
<PSEISPRTE>-ESTRT = 1.
ENDLOOP.

LOOP AT IT_PSEISPRTE INTO WA_PSEISPRTE.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_PSEISPRTE-ISTRT, sy-vline,
WA_PSEISPRTE-PENDE, sy-vline,
WA_PSEISPRTE-EENDE, sy-vline,
WA_PSEISPRTE-IENDE, sy-vline,
WA_PSEISPRTE-PDAUR, sy-vline,
WA_PSEISPRTE-EDAUR, sy-vline.
ENDLOOP. *Add any further fields from structure WA_PSEISPRTE you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_PSEISPRTE TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_PSEISPRTE INTO WA_PSEISPRTE. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.

*Conversion exit ABPSP, internal->external for field POSNR CALL FUNCTION 'CONVERSION_EXIT_ABPSP_OUTPUT' EXPORTING input = WA_PSEISPRTE-POSNR IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_PSEISPRTE-POSNR.
WRITE:/ 'New Value:', ld_input.

*Conversion exit KONPD, internal->external for field PSPHI CALL FUNCTION 'CONVERSION_EXIT_KONPD_OUTPUT' EXPORTING input = WA_PSEISPRTE-PSPHI IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_PSEISPRTE-PSPHI.
WRITE:/ 'New Value:', ld_input.

*Conversion exit CUNIT, internal->external for field IEINH CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_PSEISPRTE-IEINH IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_PSEISPRTE-IEINH.
WRITE:/ 'New Value:', ld_input.

*Conversion exit CUNIT, internal->external for field EEINH CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_PSEISPRTE-EEINH IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_PSEISPRTE-EEINH.
WRITE:/ 'New Value:', ld_input.

*Conversion exit CUNIT, internal->external for field PEINH CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_PSEISPRTE-PEINH IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_PSEISPRTE-PEINH.
WRITE:/ 'New Value:', ld_input.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_PSEISPRTE_STR,
MANDT TYPE STRING,
POSNR TYPE STRING,
PSPHI TYPE STRING,
PSTRT TYPE STRING,
ESTRT TYPE STRING,
ISTRT TYPE STRING,
PENDE TYPE STRING,
EENDE TYPE STRING,
IENDE TYPE STRING,
PDAUR TYPE STRING,
EDAUR TYPE STRING,
IDAUR TYPE STRING,
IEINH TYPE STRING,
EEINH TYPE STRING,
PEINH TYPE STRING,
FLGVG TYPE STRING,
FLGEW TYPE STRING,
FLGEM TYPE STRING,
FLGVM TYPE STRING,
FLGIM TYPE STRING,
FLGVI TYPE STRING,
PSTRM TYPE STRING,
PETRM TYPE STRING,
ESTRM TYPE STRING,
EETRM TYPE STRING,
VISTR TYPE STRING,
VIEND TYPE STRING,
PSTRS TYPE STRING,
PETRF TYPE STRING,
ESTRS TYPE STRING,
EETRF TYPE STRING,END OF T_EKKO_STR. DATA: WA_PSEISPRTE_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_PSEISPRTE_STR-MANDT sy-vline
WA_PSEISPRTE_STR-POSNR sy-vline
WA_PSEISPRTE_STR-PSPHI sy-vline
WA_PSEISPRTE_STR-PSTRT sy-vline
WA_PSEISPRTE_STR-ESTRT sy-vline
WA_PSEISPRTE_STR-ISTRT sy-vline
WA_PSEISPRTE_STR-PENDE sy-vline
WA_PSEISPRTE_STR-EENDE sy-vline
WA_PSEISPRTE_STR-IENDE sy-vline
WA_PSEISPRTE_STR-PDAUR sy-vline
WA_PSEISPRTE_STR-EDAUR sy-vline
WA_PSEISPRTE_STR-IDAUR sy-vline
WA_PSEISPRTE_STR-IEINH sy-vline
WA_PSEISPRTE_STR-EEINH sy-vline
WA_PSEISPRTE_STR-PEINH sy-vline
WA_PSEISPRTE_STR-FLGVG sy-vline
WA_PSEISPRTE_STR-FLGEW sy-vline
WA_PSEISPRTE_STR-FLGEM sy-vline
WA_PSEISPRTE_STR-FLGVM sy-vline
WA_PSEISPRTE_STR-FLGIM sy-vline
WA_PSEISPRTE_STR-FLGVI sy-vline
WA_PSEISPRTE_STR-PSTRM sy-vline
WA_PSEISPRTE_STR-PETRM sy-vline
WA_PSEISPRTE_STR-ESTRM sy-vline
WA_PSEISPRTE_STR-EETRM sy-vline
WA_PSEISPRTE_STR-VISTR sy-vline
WA_PSEISPRTE_STR-VIEND sy-vline
WA_PSEISPRTE_STR-PSTRS sy-vline
WA_PSEISPRTE_STR-PETRF sy-vline
WA_PSEISPRTE_STR-ESTRS sy-vline
WA_PSEISPRTE_STR-EETRF sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.