ABAP Select data from SAP table PSBOS_TRANSFER_DATA_REC into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP PSBOS_TRANSFER_DATA_REC table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to PSBOS_TRANSFER_DATA_REC. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the PSBOS_TRANSFER_DATA_REC table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_PSBOS_TRANSFER_DATA_REC TYPE STANDARD TABLE OF PSBOS_TRANSFER_DATA_REC,
      WA_PSBOS_TRANSFER_DATA_REC TYPE PSBOS_TRANSFER_DATA_REC,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: <PSBOS_TRANSFER_DATA_REC> TYPE PSBOS_TRANSFER_DATA_REC.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_PSBOS_TRANSFER_DATA_REC.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM PSBOS_TRANSFER_DATA_REC
  INTO TABLE IT_PSBOS_TRANSFER_DATA_REC.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM PSBOS_TRANSFER_DATA_REC
*  INTO TABLE @DATA(IT_PSBOS_TRANSFER_DATA_REC2).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_PSBOS_TRANSFER_DATA_REC INDEX 1 INTO DATA(WA_PSBOS_TRANSFER_DATA_REC2).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_PSBOS_TRANSFER_DATA_REC ASSIGNING <PSBOS_TRANSFER_DATA_REC>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
<PSBOS_TRANSFER_DATA_REC>-BOS_COST_COMPONENT = 1.
<PSBOS_TRANSFER_DATA_REC>-BOS_COST_ESTIMATE = 1.
<PSBOS_TRANSFER_DATA_REC>-BOS_COSTING_KEY = 1.
<PSBOS_TRANSFER_DATA_REC>-BZOBJ = 1.
<PSBOS_TRANSFER_DATA_REC>-KALNR = 1.
ENDLOOP.

LOOP AT IT_PSBOS_TRANSFER_DATA_REC INTO WA_PSBOS_TRANSFER_DATA_REC.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_PSBOS_TRANSFER_DATA_REC-KALKA, sy-vline,
WA_PSBOS_TRANSFER_DATA_REC-KADKY, sy-vline,
WA_PSBOS_TRANSFER_DATA_REC-TVERS, sy-vline,
WA_PSBOS_TRANSFER_DATA_REC-BWVAR, sy-vline,
WA_PSBOS_TRANSFER_DATA_REC-KKZMA, sy-vline,
WA_PSBOS_TRANSFER_DATA_REC-BOS_COMPONENT_NUMBER, sy-vline.
ENDLOOP. *Add any further fields from structure WA_PSBOS_TRANSFER_DATA_REC you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_PSBOS_TRANSFER_DATA_REC TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_PSBOS_TRANSFER_DATA_REC INTO WA_PSBOS_TRANSFER_DATA_REC. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.

*Conversion exit CUNIT, internal->external for field UNIT_OF_MEASUREBQ CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_PSBOS_TRANSFER_DATA_REC-UNIT_OF_MEASUREBQ IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_PSBOS_TRANSFER_DATA_REC-UNIT_OF_MEASUREBQ.
WRITE:/ 'New Value:', ld_input.

*Conversion exit CUNIT, internal->external for field UNIT_OF_MEASURETTQ CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_PSBOS_TRANSFER_DATA_REC-UNIT_OF_MEASURETTQ IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_PSBOS_TRANSFER_DATA_REC-UNIT_OF_MEASURETTQ.
WRITE:/ 'New Value:', ld_input.

*Conversion exit CUNIT, internal->external for field UNIT_OF_MEASURERQ CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_PSBOS_TRANSFER_DATA_REC-UNIT_OF_MEASURERQ IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_PSBOS_TRANSFER_DATA_REC-UNIT_OF_MEASURERQ.
WRITE:/ 'New Value:', ld_input.

*Conversion exit CUNIT, internal->external for field UNIT_OF_MEASUREEQ CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_PSBOS_TRANSFER_DATA_REC-UNIT_OF_MEASUREEQ IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_PSBOS_TRANSFER_DATA_REC-UNIT_OF_MEASUREEQ.
WRITE:/ 'New Value:', ld_input.

*Conversion exit CUNIT, internal->external for field UNIT_OF_MEASURERQE CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_PSBOS_TRANSFER_DATA_REC-UNIT_OF_MEASURERQE IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_PSBOS_TRANSFER_DATA_REC-UNIT_OF_MEASURERQE.
WRITE:/ 'New Value:', ld_input.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_PSBOS_TRANSFER_DATA_REC_STR,
BOS_COST_COMPONENT TYPE STRING,
BOS_COST_ESTIMATE TYPE STRING,
BOS_COSTING_KEY TYPE STRING,
BZOBJ TYPE STRING,
KALNR TYPE STRING,
KALKA TYPE STRING,
KADKY TYPE STRING,
TVERS TYPE STRING,
BWVAR TYPE STRING,
KKZMA TYPE STRING,
BOS_COMPONENT_NUMBER TYPE STRING,
TRANSFER_DETAILS TYPE STRING,
DIFFERENT_RESOURCES TYPE STRING,
INCOMPATIBLE_UNITS TYPE STRING,
CALCULATED_FLAG_FOR_CE TYPE STRING,
HEAD_FACTOR TYPE STRING,
PATH_FACTOR TYPE STRING,
PROPORTION_OF_CE_VALUE TYPE STRING,
OVER_TRANSFER_NORMALIZE_FACTOR TYPE STRING,
QUANTITYBQ TYPE STRING,
UNIT_OF_MEASUREBQ TYPE STRING,
QUANTITYTTQ TYPE STRING,
UNIT_OF_MEASURETTQ TYPE STRING,
QUANTITYRQ TYPE STRING,
UNIT_OF_MEASURERQ TYPE STRING,
QUANTITYEQ TYPE STRING,
UNIT_OF_MEASUREEQ TYPE STRING,
QUANTITYRQE TYPE STRING,
UNIT_OF_MEASURERQE TYPE STRING,
VALUECABV TYPE STRING,
CURRENCYCABV TYPE STRING,
VALUETRBV TYPE STRING,
CURRENCYTRBV TYPE STRING,
VALUEOBBV TYPE STRING,
CURRENCYOBBV TYPE STRING,
VALUECATTV TYPE STRING,
CURRENCYCATTV TYPE STRING,
VALUETRTTV TYPE STRING,
CURRENCYTRTTV TYPE STRING,
VALUEOBTTV TYPE STRING,
CURRENCYOBTTV TYPE STRING,
VALUECARV TYPE STRING,
CURRENCYCARV TYPE STRING,
VALUETRRV TYPE STRING,
CURRENCYTRRV TYPE STRING,
VALUEOBRV TYPE STRING,
CURRENCYOBRV TYPE STRING,
VALUECAEV TYPE STRING,
CURRENCYCAEV TYPE STRING,
VALUETREV TYPE STRING,
CURRENCYTREV TYPE STRING,
VALUEOBEV TYPE STRING,
CURRENCYOBEV TYPE STRING,
VALUECARVE TYPE STRING,
CURRENCYCARVE TYPE STRING,
VALUETRRVE TYPE STRING,
CURRENCYTRRVE TYPE STRING,
VALUEOBRVE TYPE STRING,
CURRENCYOBRVE TYPE STRING,
BOSPS_IDX TYPE STRING,
BOSPS_ICON TYPE STRING,END OF T_EKKO_STR. DATA: WA_PSBOS_TRANSFER_DATA_REC_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_PSBOS_TRANSFER_DATA_REC_STR-BOS_COST_COMPONENT sy-vline
WA_PSBOS_TRANSFER_DATA_REC_STR-BOS_COST_ESTIMATE sy-vline
WA_PSBOS_TRANSFER_DATA_REC_STR-BOS_COSTING_KEY sy-vline
WA_PSBOS_TRANSFER_DATA_REC_STR-BZOBJ sy-vline
WA_PSBOS_TRANSFER_DATA_REC_STR-KALNR sy-vline
WA_PSBOS_TRANSFER_DATA_REC_STR-KALKA sy-vline
WA_PSBOS_TRANSFER_DATA_REC_STR-KADKY sy-vline
WA_PSBOS_TRANSFER_DATA_REC_STR-TVERS sy-vline
WA_PSBOS_TRANSFER_DATA_REC_STR-BWVAR sy-vline
WA_PSBOS_TRANSFER_DATA_REC_STR-KKZMA sy-vline
WA_PSBOS_TRANSFER_DATA_REC_STR-BOS_COMPONENT_NUMBER sy-vline
WA_PSBOS_TRANSFER_DATA_REC_STR-TRANSFER_DETAILS sy-vline
WA_PSBOS_TRANSFER_DATA_REC_STR-DIFFERENT_RESOURCES sy-vline
WA_PSBOS_TRANSFER_DATA_REC_STR-INCOMPATIBLE_UNITS sy-vline
WA_PSBOS_TRANSFER_DATA_REC_STR-CALCULATED_FLAG_FOR_CE sy-vline
WA_PSBOS_TRANSFER_DATA_REC_STR-HEAD_FACTOR sy-vline
WA_PSBOS_TRANSFER_DATA_REC_STR-PATH_FACTOR sy-vline
WA_PSBOS_TRANSFER_DATA_REC_STR-PROPORTION_OF_CE_VALUE sy-vline
WA_PSBOS_TRANSFER_DATA_REC_STR-OVER_TRANSFER_NORMALIZE_FACTOR sy-vline
WA_PSBOS_TRANSFER_DATA_REC_STR-QUANTITYBQ sy-vline
WA_PSBOS_TRANSFER_DATA_REC_STR-UNIT_OF_MEASUREBQ sy-vline
WA_PSBOS_TRANSFER_DATA_REC_STR-QUANTITYTTQ sy-vline
WA_PSBOS_TRANSFER_DATA_REC_STR-UNIT_OF_MEASURETTQ sy-vline
WA_PSBOS_TRANSFER_DATA_REC_STR-QUANTITYRQ sy-vline
WA_PSBOS_TRANSFER_DATA_REC_STR-UNIT_OF_MEASURERQ sy-vline
WA_PSBOS_TRANSFER_DATA_REC_STR-QUANTITYEQ sy-vline
WA_PSBOS_TRANSFER_DATA_REC_STR-UNIT_OF_MEASUREEQ sy-vline
WA_PSBOS_TRANSFER_DATA_REC_STR-QUANTITYRQE sy-vline
WA_PSBOS_TRANSFER_DATA_REC_STR-UNIT_OF_MEASURERQE sy-vline
WA_PSBOS_TRANSFER_DATA_REC_STR-VALUECABV sy-vline
WA_PSBOS_TRANSFER_DATA_REC_STR-CURRENCYCABV sy-vline
WA_PSBOS_TRANSFER_DATA_REC_STR-VALUETRBV sy-vline
WA_PSBOS_TRANSFER_DATA_REC_STR-CURRENCYTRBV sy-vline
WA_PSBOS_TRANSFER_DATA_REC_STR-VALUEOBBV sy-vline
WA_PSBOS_TRANSFER_DATA_REC_STR-CURRENCYOBBV sy-vline
WA_PSBOS_TRANSFER_DATA_REC_STR-VALUECATTV sy-vline
WA_PSBOS_TRANSFER_DATA_REC_STR-CURRENCYCATTV sy-vline
WA_PSBOS_TRANSFER_DATA_REC_STR-VALUETRTTV sy-vline
WA_PSBOS_TRANSFER_DATA_REC_STR-CURRENCYTRTTV sy-vline
WA_PSBOS_TRANSFER_DATA_REC_STR-VALUEOBTTV sy-vline
WA_PSBOS_TRANSFER_DATA_REC_STR-CURRENCYOBTTV sy-vline
WA_PSBOS_TRANSFER_DATA_REC_STR-VALUECARV sy-vline
WA_PSBOS_TRANSFER_DATA_REC_STR-CURRENCYCARV sy-vline
WA_PSBOS_TRANSFER_DATA_REC_STR-VALUETRRV sy-vline
WA_PSBOS_TRANSFER_DATA_REC_STR-CURRENCYTRRV sy-vline
WA_PSBOS_TRANSFER_DATA_REC_STR-VALUEOBRV sy-vline
WA_PSBOS_TRANSFER_DATA_REC_STR-CURRENCYOBRV sy-vline
WA_PSBOS_TRANSFER_DATA_REC_STR-VALUECAEV sy-vline
WA_PSBOS_TRANSFER_DATA_REC_STR-CURRENCYCAEV sy-vline
WA_PSBOS_TRANSFER_DATA_REC_STR-VALUETREV sy-vline
WA_PSBOS_TRANSFER_DATA_REC_STR-CURRENCYTREV sy-vline
WA_PSBOS_TRANSFER_DATA_REC_STR-VALUEOBEV sy-vline
WA_PSBOS_TRANSFER_DATA_REC_STR-CURRENCYOBEV sy-vline
WA_PSBOS_TRANSFER_DATA_REC_STR-VALUECARVE sy-vline
WA_PSBOS_TRANSFER_DATA_REC_STR-CURRENCYCARVE sy-vline
WA_PSBOS_TRANSFER_DATA_REC_STR-VALUETRRVE sy-vline
WA_PSBOS_TRANSFER_DATA_REC_STR-CURRENCYTRRVE sy-vline
WA_PSBOS_TRANSFER_DATA_REC_STR-VALUEOBRVE sy-vline
WA_PSBOS_TRANSFER_DATA_REC_STR-CURRENCYOBRVE sy-vline
WA_PSBOS_TRANSFER_DATA_REC_STR-BOSPS_IDX sy-vline
WA_PSBOS_TRANSFER_DATA_REC_STR-BOSPS_ICON sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.