ABAP Select data from SAP table PSB_GENIL_WBS_DATES_ATTR_ST into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP PSB_GENIL_WBS_DATES_ATTR_ST table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to PSB_GENIL_WBS_DATES_ATTR_ST. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the PSB_GENIL_WBS_DATES_ATTR_ST table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_PSB_GENIL_WBS_DATES_ATTR_ST TYPE STANDARD TABLE OF PSB_GENIL_WBS_DATES_ATTR_ST,
      WA_PSB_GENIL_WBS_DATES_ATTR_ST TYPE PSB_GENIL_WBS_DATES_ATTR_ST,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: <PSB_GENIL_WBS_DATES_ATTR_ST> TYPE PSB_GENIL_WBS_DATES_ATTR_ST.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_PSB_GENIL_WBS_DATES_ATTR_ST.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM PSB_GENIL_WBS_DATES_ATTR_ST
  INTO TABLE IT_PSB_GENIL_WBS_DATES_ATTR_ST.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM PSB_GENIL_WBS_DATES_ATTR_ST
*  INTO TABLE @DATA(IT_PSB_GENIL_WBS_DATES_ATTR_ST2).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_PSB_GENIL_WBS_DATES_ATTR_ST INDEX 1 INTO DATA(WA_PSB_GENIL_WBS_DATES_ATTR_ST2).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_PSB_GENIL_WBS_DATES_ATTR_ST ASSIGNING <PSB_GENIL_WBS_DATES_ATTR_ST>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
<PSB_GENIL_WBS_DATES_ATTR_ST>-OBJNR = 1.
<PSB_GENIL_WBS_DATES_ATTR_ST>-MANDT = 1.
<PSB_GENIL_WBS_DATES_ATTR_ST>-POSNR = 1.
<PSB_GENIL_WBS_DATES_ATTR_ST>-PSPHI = 1.
<PSB_GENIL_WBS_DATES_ATTR_ST>-PSTRT = 1.
ENDLOOP.

LOOP AT IT_PSB_GENIL_WBS_DATES_ATTR_ST INTO WA_PSB_GENIL_WBS_DATES_ATTR_ST.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_PSB_GENIL_WBS_DATES_ATTR_ST-ESTRT, sy-vline,
WA_PSB_GENIL_WBS_DATES_ATTR_ST-ISTRT, sy-vline,
WA_PSB_GENIL_WBS_DATES_ATTR_ST-PENDE, sy-vline,
WA_PSB_GENIL_WBS_DATES_ATTR_ST-EENDE, sy-vline,
WA_PSB_GENIL_WBS_DATES_ATTR_ST-IENDE, sy-vline,
WA_PSB_GENIL_WBS_DATES_ATTR_ST-PDAUR, sy-vline.
ENDLOOP. *Add any further fields from structure WA_PSB_GENIL_WBS_DATES_ATTR_ST you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_PSB_GENIL_WBS_DATES_ATTR_ST TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_PSB_GENIL_WBS_DATES_ATTR_ST INTO WA_PSB_GENIL_WBS_DATES_ATTR_ST. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.

*Conversion exit KONPD, internal->external for field PSPHI CALL FUNCTION 'CONVERSION_EXIT_KONPD_OUTPUT' EXPORTING input = WA_PSB_GENIL_WBS_DATES_ATTR_ST-PSPHI IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_PSB_GENIL_WBS_DATES_ATTR_ST-PSPHI.
WRITE:/ 'New Value:', ld_input.

*Conversion exit CUNIT, internal->external for field IEINH CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_PSB_GENIL_WBS_DATES_ATTR_ST-IEINH IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_PSB_GENIL_WBS_DATES_ATTR_ST-IEINH.
WRITE:/ 'New Value:', ld_input.

*Conversion exit CUNIT, internal->external for field EEINH CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_PSB_GENIL_WBS_DATES_ATTR_ST-EEINH IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_PSB_GENIL_WBS_DATES_ATTR_ST-EEINH.
WRITE:/ 'New Value:', ld_input.

*Conversion exit CUNIT, internal->external for field PEINH CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_PSB_GENIL_WBS_DATES_ATTR_ST-PEINH IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_PSB_GENIL_WBS_DATES_ATTR_ST-PEINH.
WRITE:/ 'New Value:', ld_input.

*Conversion exit KONPD, internal->external for field PSPHI CALL FUNCTION 'CONVERSION_EXIT_KONPD_OUTPUT' EXPORTING input = WA_PSB_GENIL_WBS_DATES_ATTR_ST-PSPHI IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_PSB_GENIL_WBS_DATES_ATTR_ST-PSPHI.
WRITE:/ 'New Value:', ld_input.

*Conversion exit CUNIT, internal->external for field IEINH CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_PSB_GENIL_WBS_DATES_ATTR_ST-IEINH IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_PSB_GENIL_WBS_DATES_ATTR_ST-IEINH.
WRITE:/ 'New Value:', ld_input.

*Conversion exit CUNIT, internal->external for field EEINH CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_PSB_GENIL_WBS_DATES_ATTR_ST-EEINH IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_PSB_GENIL_WBS_DATES_ATTR_ST-EEINH.
WRITE:/ 'New Value:', ld_input.

*Conversion exit CUNIT, internal->external for field PEINH CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_PSB_GENIL_WBS_DATES_ATTR_ST-PEINH IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_PSB_GENIL_WBS_DATES_ATTR_ST-PEINH.
WRITE:/ 'New Value:', ld_input.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_PSB_GENIL_WBS_DATES_ATTR_ST_STR,
OBJNR TYPE STRING,
MANDT TYPE STRING,
POSNR TYPE STRING,
PSPHI TYPE STRING,
PSTRT TYPE STRING,
ESTRT TYPE STRING,
ISTRT TYPE STRING,
PENDE TYPE STRING,
EENDE TYPE STRING,
IENDE TYPE STRING,
PDAUR TYPE STRING,
EDAUR TYPE STRING,
IDAUR TYPE STRING,
IEINH TYPE STRING,
EEINH TYPE STRING,
PEINH TYPE STRING,
FLGVG TYPE STRING,
FLGEW TYPE STRING,
FLGEM TYPE STRING,
FLGVM TYPE STRING,
FLGIM TYPE STRING,
FLGVI TYPE STRING,
PSTRM TYPE STRING,
PETRM TYPE STRING,
ESTRM TYPE STRING,
EETRM TYPE STRING,
VISTR TYPE STRING,
VIEND TYPE STRING,
PSTRS TYPE STRING,
PETRF TYPE STRING,
ESTRS TYPE STRING,
EETRF TYPE STRING,
PSPHI TYPE STRING,
PSTRT TYPE STRING,
ESTRT TYPE STRING,
ISTRT TYPE STRING,
PENDE TYPE STRING,
EENDE TYPE STRING,
IENDE TYPE STRING,
PDAUR TYPE STRING,
EDAUR TYPE STRING,
IDAUR TYPE STRING,
IEINH TYPE STRING,
EEINH TYPE STRING,
PEINH TYPE STRING,
FLGVG TYPE STRING,
FLGEW TYPE STRING,
FLGEM TYPE STRING,
FLGVM TYPE STRING,
FLGIM TYPE STRING,
FLGVI TYPE STRING,
PSTRM TYPE STRING,
PETRM TYPE STRING,
ESTRM TYPE STRING,
EETRM TYPE STRING,
VISTR TYPE STRING,
VIEND TYPE STRING,
PSTRS TYPE STRING,
PETRF TYPE STRING,
ESTRS TYPE STRING,
EETRF TYPE STRING,END OF T_EKKO_STR. DATA: WA_PSB_GENIL_WBS_DATES_ATTR_ST_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_PSB_GENIL_WBS_DATES_ATTR_ST_STR-OBJNR sy-vline
WA_PSB_GENIL_WBS_DATES_ATTR_ST_STR-MANDT sy-vline
WA_PSB_GENIL_WBS_DATES_ATTR_ST_STR-POSNR sy-vline
WA_PSB_GENIL_WBS_DATES_ATTR_ST_STR-PSPHI sy-vline
WA_PSB_GENIL_WBS_DATES_ATTR_ST_STR-PSTRT sy-vline
WA_PSB_GENIL_WBS_DATES_ATTR_ST_STR-ESTRT sy-vline
WA_PSB_GENIL_WBS_DATES_ATTR_ST_STR-ISTRT sy-vline
WA_PSB_GENIL_WBS_DATES_ATTR_ST_STR-PENDE sy-vline
WA_PSB_GENIL_WBS_DATES_ATTR_ST_STR-EENDE sy-vline
WA_PSB_GENIL_WBS_DATES_ATTR_ST_STR-IENDE sy-vline
WA_PSB_GENIL_WBS_DATES_ATTR_ST_STR-PDAUR sy-vline
WA_PSB_GENIL_WBS_DATES_ATTR_ST_STR-EDAUR sy-vline
WA_PSB_GENIL_WBS_DATES_ATTR_ST_STR-IDAUR sy-vline
WA_PSB_GENIL_WBS_DATES_ATTR_ST_STR-IEINH sy-vline
WA_PSB_GENIL_WBS_DATES_ATTR_ST_STR-EEINH sy-vline
WA_PSB_GENIL_WBS_DATES_ATTR_ST_STR-PEINH sy-vline
WA_PSB_GENIL_WBS_DATES_ATTR_ST_STR-FLGVG sy-vline
WA_PSB_GENIL_WBS_DATES_ATTR_ST_STR-FLGEW sy-vline
WA_PSB_GENIL_WBS_DATES_ATTR_ST_STR-FLGEM sy-vline
WA_PSB_GENIL_WBS_DATES_ATTR_ST_STR-FLGVM sy-vline
WA_PSB_GENIL_WBS_DATES_ATTR_ST_STR-FLGIM sy-vline
WA_PSB_GENIL_WBS_DATES_ATTR_ST_STR-FLGVI sy-vline
WA_PSB_GENIL_WBS_DATES_ATTR_ST_STR-PSTRM sy-vline
WA_PSB_GENIL_WBS_DATES_ATTR_ST_STR-PETRM sy-vline
WA_PSB_GENIL_WBS_DATES_ATTR_ST_STR-ESTRM sy-vline
WA_PSB_GENIL_WBS_DATES_ATTR_ST_STR-EETRM sy-vline
WA_PSB_GENIL_WBS_DATES_ATTR_ST_STR-VISTR sy-vline
WA_PSB_GENIL_WBS_DATES_ATTR_ST_STR-VIEND sy-vline
WA_PSB_GENIL_WBS_DATES_ATTR_ST_STR-PSTRS sy-vline
WA_PSB_GENIL_WBS_DATES_ATTR_ST_STR-PETRF sy-vline
WA_PSB_GENIL_WBS_DATES_ATTR_ST_STR-ESTRS sy-vline
WA_PSB_GENIL_WBS_DATES_ATTR_ST_STR-EETRF sy-vline
WA_PSB_GENIL_WBS_DATES_ATTR_ST_STR-PSPHI sy-vline
WA_PSB_GENIL_WBS_DATES_ATTR_ST_STR-PSTRT sy-vline
WA_PSB_GENIL_WBS_DATES_ATTR_ST_STR-ESTRT sy-vline
WA_PSB_GENIL_WBS_DATES_ATTR_ST_STR-ISTRT sy-vline
WA_PSB_GENIL_WBS_DATES_ATTR_ST_STR-PENDE sy-vline
WA_PSB_GENIL_WBS_DATES_ATTR_ST_STR-EENDE sy-vline
WA_PSB_GENIL_WBS_DATES_ATTR_ST_STR-IENDE sy-vline
WA_PSB_GENIL_WBS_DATES_ATTR_ST_STR-PDAUR sy-vline
WA_PSB_GENIL_WBS_DATES_ATTR_ST_STR-EDAUR sy-vline
WA_PSB_GENIL_WBS_DATES_ATTR_ST_STR-IDAUR sy-vline
WA_PSB_GENIL_WBS_DATES_ATTR_ST_STR-IEINH sy-vline
WA_PSB_GENIL_WBS_DATES_ATTR_ST_STR-EEINH sy-vline
WA_PSB_GENIL_WBS_DATES_ATTR_ST_STR-PEINH sy-vline
WA_PSB_GENIL_WBS_DATES_ATTR_ST_STR-FLGVG sy-vline
WA_PSB_GENIL_WBS_DATES_ATTR_ST_STR-FLGEW sy-vline
WA_PSB_GENIL_WBS_DATES_ATTR_ST_STR-FLGEM sy-vline
WA_PSB_GENIL_WBS_DATES_ATTR_ST_STR-FLGVM sy-vline
WA_PSB_GENIL_WBS_DATES_ATTR_ST_STR-FLGIM sy-vline
WA_PSB_GENIL_WBS_DATES_ATTR_ST_STR-FLGVI sy-vline
WA_PSB_GENIL_WBS_DATES_ATTR_ST_STR-PSTRM sy-vline
WA_PSB_GENIL_WBS_DATES_ATTR_ST_STR-PETRM sy-vline
WA_PSB_GENIL_WBS_DATES_ATTR_ST_STR-ESTRM sy-vline
WA_PSB_GENIL_WBS_DATES_ATTR_ST_STR-EETRM sy-vline
WA_PSB_GENIL_WBS_DATES_ATTR_ST_STR-VISTR sy-vline
WA_PSB_GENIL_WBS_DATES_ATTR_ST_STR-VIEND sy-vline
WA_PSB_GENIL_WBS_DATES_ATTR_ST_STR-PSTRS sy-vline
WA_PSB_GENIL_WBS_DATES_ATTR_ST_STR-PETRF sy-vline
WA_PSB_GENIL_WBS_DATES_ATTR_ST_STR-ESTRS sy-vline
WA_PSB_GENIL_WBS_DATES_ATTR_ST_STR-EETRF sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.