ABAP Select data from SAP table PS0616 into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP PS0616 table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to PS0616. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the PS0616 table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_PS0616 TYPE STANDARD TABLE OF PS0616,
      WA_PS0616 TYPE PS0616,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: <PS0616> TYPE PS0616.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_PS0616.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM PS0616
  INTO TABLE IT_PS0616.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM PS0616
*  INTO TABLE @DATA(IT_PS06162).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_PS0616 INDEX 1 INTO DATA(WA_PS06162).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_PS0616 ASSIGNING <PS0616>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
<PS0616>-WAERS = 1.
<PS0616>-REPRT = 1.
<PS0616>-CAMPID = 1.
<PS0616>-STAFFID = 1.
<PS0616>-BIRTHDTE = 1.
ENDLOOP.

LOOP AT IT_PS0616 INTO WA_PS0616.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_PS0616-GENDER, sy-vline,
WA_PS0616-TERMS, sy-vline,
WA_PS0616-MOE, sy-vline,
WA_PS0616-PEMPFUN, sy-vline,
WA_PS0616-PERACA, sy-vline,
WA_PS0616-FTE, sy-vline.
ENDLOOP. *Add any further fields from structure WA_PS0616 you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_PS0616 TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_PS0616 INTO WA_PS0616. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.

*Conversion exit PDATE, internal->external for field BIRTHDTE CALL FUNCTION 'CONVERSION_EXIT_PDATE_OUTPUT' EXPORTING input = WA_PS0616-BIRTHDTE IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_PS0616-BIRTHDTE.
WRITE:/ 'New Value:', ld_input.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_PS0616_STR,
WAERS TYPE STRING,
REPRT TYPE STRING,
CAMPID TYPE STRING,
STAFFID TYPE STRING,
BIRTHDTE TYPE STRING,
GENDER TYPE STRING,
TERMS TYPE STRING,
MOE TYPE STRING,
PEMPFUN TYPE STRING,
PERACA TYPE STRING,
FTE TYPE STRING,
CCENTRE TYPE STRING,
NATION TYPE STRING,
ETHNIC TYPE STRING,
DISABLE TYPE STRING,
DATEHEI TYPE STRING,
QUALHELD TYPE STRING,
ACCDIS TYPE STRING,
PROFQHLD TYPE STRING,
RESACT TYPE STRING,
ABLWELSH TYPE STRING,
TCHWLH TYPE STRING,
CLINSTAT TYPE STRING,
NHSJOINT TYPE STRING,
GRADE TYPE STRING,
PSOS TYPE STRING,
PSCAGI TYPE STRING,
SSOS TYPE STRING,
SALPOINT TYPE STRING,
SALARY TYPE STRING,
EMPPREYR TYPE STRING,
DATELHEI TYPE STRING,
DEST TYPE STRING,
SENPH TYPE STRING,
SREAD TYPE STRING,
APPCONT TYPE STRING,
UOA TYPE STRING,END OF T_EKKO_STR. DATA: WA_PS0616_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_PS0616_STR-WAERS sy-vline
WA_PS0616_STR-REPRT sy-vline
WA_PS0616_STR-CAMPID sy-vline
WA_PS0616_STR-STAFFID sy-vline
WA_PS0616_STR-BIRTHDTE sy-vline
WA_PS0616_STR-GENDER sy-vline
WA_PS0616_STR-TERMS sy-vline
WA_PS0616_STR-MOE sy-vline
WA_PS0616_STR-PEMPFUN sy-vline
WA_PS0616_STR-PERACA sy-vline
WA_PS0616_STR-FTE sy-vline
WA_PS0616_STR-CCENTRE sy-vline
WA_PS0616_STR-NATION sy-vline
WA_PS0616_STR-ETHNIC sy-vline
WA_PS0616_STR-DISABLE sy-vline
WA_PS0616_STR-DATEHEI sy-vline
WA_PS0616_STR-QUALHELD sy-vline
WA_PS0616_STR-ACCDIS sy-vline
WA_PS0616_STR-PROFQHLD sy-vline
WA_PS0616_STR-RESACT sy-vline
WA_PS0616_STR-ABLWELSH sy-vline
WA_PS0616_STR-TCHWLH sy-vline
WA_PS0616_STR-CLINSTAT sy-vline
WA_PS0616_STR-NHSJOINT sy-vline
WA_PS0616_STR-GRADE sy-vline
WA_PS0616_STR-PSOS sy-vline
WA_PS0616_STR-PSCAGI sy-vline
WA_PS0616_STR-SSOS sy-vline
WA_PS0616_STR-SALPOINT sy-vline
WA_PS0616_STR-SALARY sy-vline
WA_PS0616_STR-EMPPREYR sy-vline
WA_PS0616_STR-DATELHEI sy-vline
WA_PS0616_STR-DEST sy-vline
WA_PS0616_STR-SENPH sy-vline
WA_PS0616_STR-SREAD sy-vline
WA_PS0616_STR-APPCONT sy-vline
WA_PS0616_STR-UOA sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.