ABAP Select data from SAP table PS0570 into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP PS0570 table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to PS0570. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the PS0570 table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_PS0570 TYPE STANDARD TABLE OF PS0570,
      WA_PS0570 TYPE PS0570,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: <PS0570> TYPE PS0570.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_PS0570.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM PS0570
  INTO TABLE IT_PS0570.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM PS0570
*  INTO TABLE @DATA(IT_PS05702).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_PS0570 INDEX 1 INTO DATA(WA_PS05702).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_PS0570 ASSIGNING <PS0570>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
<PS0570>-ISLE = 1.
<PS0570>-O46B = 1.
<PS0570>-S46B = 1.
<PS0570>-R46B = 1.
<PS0570>-GYTXN = 1.
ENDLOOP.

LOOP AT IT_PS0570 INTO WA_PS0570.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_PS0570-GYTXC, sy-vline,
WA_PS0570-GYTCS, sy-vline,
WA_PS0570-DIRNT, sy-vline,
WA_PS0570-DNAMT, sy-vline,
WA_PS0570-DNDAY, sy-vline,
WA_PS0570-DNDAT, sy-vline.
ENDLOOP. *Add any further fields from structure WA_PS0570 you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_PS0570 TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_PS0570 INTO WA_PS0570. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_PS0570_STR,
ISLE TYPE STRING,
O46B TYPE STRING,
S46B TYPE STRING,
R46B TYPE STRING,
GYTXN TYPE STRING,
GYTXC TYPE STRING,
GYTCS TYPE STRING,
DIRNT TYPE STRING,
DNAMT TYPE STRING,
DNDAY TYPE STRING,
DNDAT TYPE STRING,
DNREC TYPE STRING,
CERT1 TYPE STRING,
CERT2 TYPE STRING,
CERT3 TYPE STRING,
RESID TYPE STRING,
TXREF TYPE STRING,
T10RC TYPE STRING,
IMTXC TYPE STRING,
IMTCS TYPE STRING,
TCREC TYPE STRING,END OF T_EKKO_STR. DATA: WA_PS0570_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_PS0570_STR-ISLE sy-vline
WA_PS0570_STR-O46B sy-vline
WA_PS0570_STR-S46B sy-vline
WA_PS0570_STR-R46B sy-vline
WA_PS0570_STR-GYTXN sy-vline
WA_PS0570_STR-GYTXC sy-vline
WA_PS0570_STR-GYTCS sy-vline
WA_PS0570_STR-DIRNT sy-vline
WA_PS0570_STR-DNAMT sy-vline
WA_PS0570_STR-DNDAY sy-vline
WA_PS0570_STR-DNDAT sy-vline
WA_PS0570_STR-DNREC sy-vline
WA_PS0570_STR-CERT1 sy-vline
WA_PS0570_STR-CERT2 sy-vline
WA_PS0570_STR-CERT3 sy-vline
WA_PS0570_STR-RESID sy-vline
WA_PS0570_STR-TXREF sy-vline
WA_PS0570_STR-T10RC sy-vline
WA_PS0570_STR-IMTXC sy-vline
WA_PS0570_STR-IMTCS sy-vline
WA_PS0570_STR-TCREC sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.