ABAP Select data from SAP table PS0502 into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP PS0502 table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to PS0502. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the PS0502 table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_PS0502 TYPE STANDARD TABLE OF PS0502,
      WA_PS0502 TYPE PS0502,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: <PS0502> TYPE PS0502.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_PS0502.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM PS0502
  INTO TABLE IT_PS0502.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM PS0502
*  INTO TABLE @DATA(IT_PS05022).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_PS0502 INDEX 1 INTO DATA(WA_PS05022).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_PS0502 ASSIGNING <PS0502>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
<PS0502>-DATIS = 1.
<PS0502>-APTYP = 1.
<PS0502>-APSTS = 1.
<PS0502>-OVLDT = 1.
<PS0502>-REFNO = 1.
ENDLOOP.

LOOP AT IT_PS0502 INTO WA_PS0502.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_PS0502-DATJO, sy-vline,
WA_PS0502-TENOF, sy-vline,
WA_PS0502-DIVST, sy-vline,
WA_PS0502-JOBTI, sy-vline,
WA_PS0502-SLTYP, sy-vline,
WA_PS0502-JOBGR, sy-vline.
ENDLOOP. *Add any further fields from structure WA_PS0502 you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_PS0502 TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_PS0502 INTO WA_PS0502. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_PS0502_STR,
DATIS TYPE STRING,
APTYP TYPE STRING,
APSTS TYPE STRING,
OVLDT TYPE STRING,
REFNO TYPE STRING,
DATJO TYPE STRING,
TENOF TYPE STRING,
DIVST TYPE STRING,
JOBTI TYPE STRING,
SLTYP TYPE STRING,
JOBGR TYPE STRING,
JOBGD TYPE STRING,
SLLVL TYPE STRING,
SCODE TYPE STRING,
BARID TYPE STRING,
SLEVL TYPE STRING,
HRSWK TYPE STRING,
TUNIT TYPE STRING,
AWSFL TYPE STRING,
TRMSV TYPE STRING,
RCOST TYPE STRING,
FSIGN TYPE STRING,
LSIGN TYPE STRING,
WITN1 TYPE STRING,
WITN2 TYPE STRING,
PNUM2 TYPE STRING,
SCGRP TYPE STRING,
ICTYP TYPE STRING,
ICNUM TYPE STRING,
PRBZT TYPE STRING,
PRUNT TYPE STRING,
PXTNS TYPE STRING,
PXUNT TYPE STRING,
BETRG TYPE STRING,
SVINC TYPE STRING,
VPAYM TYPE STRING,
ALLWN TYPE STRING,END OF T_EKKO_STR. DATA: WA_PS0502_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_PS0502_STR-DATIS sy-vline
WA_PS0502_STR-APTYP sy-vline
WA_PS0502_STR-APSTS sy-vline
WA_PS0502_STR-OVLDT sy-vline
WA_PS0502_STR-REFNO sy-vline
WA_PS0502_STR-DATJO sy-vline
WA_PS0502_STR-TENOF sy-vline
WA_PS0502_STR-DIVST sy-vline
WA_PS0502_STR-JOBTI sy-vline
WA_PS0502_STR-SLTYP sy-vline
WA_PS0502_STR-JOBGR sy-vline
WA_PS0502_STR-JOBGD sy-vline
WA_PS0502_STR-SLLVL sy-vline
WA_PS0502_STR-SCODE sy-vline
WA_PS0502_STR-BARID sy-vline
WA_PS0502_STR-SLEVL sy-vline
WA_PS0502_STR-HRSWK sy-vline
WA_PS0502_STR-TUNIT sy-vline
WA_PS0502_STR-AWSFL sy-vline
WA_PS0502_STR-TRMSV sy-vline
WA_PS0502_STR-RCOST sy-vline
WA_PS0502_STR-FSIGN sy-vline
WA_PS0502_STR-LSIGN sy-vline
WA_PS0502_STR-WITN1 sy-vline
WA_PS0502_STR-WITN2 sy-vline
WA_PS0502_STR-PNUM2 sy-vline
WA_PS0502_STR-SCGRP sy-vline
WA_PS0502_STR-ICTYP sy-vline
WA_PS0502_STR-ICNUM sy-vline
WA_PS0502_STR-PRBZT sy-vline
WA_PS0502_STR-PRUNT sy-vline
WA_PS0502_STR-PXTNS sy-vline
WA_PS0502_STR-PXUNT sy-vline
WA_PS0502_STR-BETRG sy-vline
WA_PS0502_STR-SVINC sy-vline
WA_PS0502_STR-VPAYM sy-vline
WA_PS0502_STR-ALLWN sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.