ABAP Select data from SAP table PS0087 into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP PS0087 table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to PS0087. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the PS0087 table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_PS0087 TYPE STANDARD TABLE OF PS0087,
      WA_PS0087 TYPE PS0087,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: <PS0087> TYPE PS0087.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_PS0087.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM PS0087
  INTO TABLE IT_PS0087.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM PS0087
*  INTO TABLE @DATA(IT_PS00872).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_PS0087 INDEX 1 INTO DATA(WA_PS00872).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_PS0087 ASSIGNING <PS0087>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
<PS0087>-RECDT = 1.
<PS0087>-DLYRT = 1.
<PS0087>-TOTAM = 1.
<PS0087>-CERFL = 1.
<PS0087>-CERDT = 1.
ENDLOOP.

LOOP AT IT_PS0087 INTO WA_PS0087.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_PS0087-CBEG1, sy-vline,
WA_PS0087-CEND1, sy-vline,
WA_PS0087-CRSN1, sy-vline,
WA_PS0087-CTXT1, sy-vline,
WA_PS0087-CBEG2, sy-vline,
WA_PS0087-CEND2, sy-vline.
ENDLOOP. *Add any further fields from structure WA_PS0087 you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_PS0087 TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_PS0087 INTO WA_PS0087. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_PS0087_STR,
RECDT TYPE STRING,
DLYRT TYPE STRING,
TOTAM TYPE STRING,
CERFL TYPE STRING,
CERDT TYPE STRING,
CBEG1 TYPE STRING,
CEND1 TYPE STRING,
CRSN1 TYPE STRING,
CTXT1 TYPE STRING,
CBEG2 TYPE STRING,
CEND2 TYPE STRING,
CRSN2 TYPE STRING,
CTXT2 TYPE STRING,
CBEG3 TYPE STRING,
CEND3 TYPE STRING,
CRSN3 TYPE STRING,
CTXT3 TYPE STRING,END OF T_EKKO_STR. DATA: WA_PS0087_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_PS0087_STR-RECDT sy-vline
WA_PS0087_STR-DLYRT sy-vline
WA_PS0087_STR-TOTAM sy-vline
WA_PS0087_STR-CERFL sy-vline
WA_PS0087_STR-CERDT sy-vline
WA_PS0087_STR-CBEG1 sy-vline
WA_PS0087_STR-CEND1 sy-vline
WA_PS0087_STR-CRSN1 sy-vline
WA_PS0087_STR-CTXT1 sy-vline
WA_PS0087_STR-CBEG2 sy-vline
WA_PS0087_STR-CEND2 sy-vline
WA_PS0087_STR-CRSN2 sy-vline
WA_PS0087_STR-CTXT2 sy-vline
WA_PS0087_STR-CBEG3 sy-vline
WA_PS0087_STR-CEND3 sy-vline
WA_PS0087_STR-CRSN3 sy-vline
WA_PS0087_STR-CTXT3 sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.