ABAP Select data from SAP table PRUWC into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP PRUWC table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to PRUWC. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the PRUWC table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_PRUWC TYPE STANDARD TABLE OF PRUWC,
      WA_PRUWC TYPE PRUWC,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: <PRUWC> TYPE PRUWC.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_PRUWC.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM PRUWC
  INTO TABLE IT_PRUWC.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM PRUWC
*  INTO TABLE @DATA(IT_PRUWC2).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_PRUWC INDEX 1 INTO DATA(WA_PRUWC2).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_PRUWC ASSIGNING <PRUWC>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
<PRUWC>-MASSN = 1.
<PRUWC>-MASSG = 1.
<PRUWC>-STAT1 = 1.
<PRUWC>-STAT2 = 1.
<PRUWC>-STAT3 = 1.
ENDLOOP.

LOOP AT IT_PRUWC INTO WA_PRUWC.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_PRUWC-AKTIVJN, sy-vline,
WA_PRUWC-NGTGS, sy-vline,
WA_PRUWC-WERKS, sy-vline,
WA_PRUWC-BTRTL, sy-vline,
WA_PRUWC-KOSTL, sy-vline,
WA_PRUWC-PERSG, sy-vline.
ENDLOOP. *Add any further fields from structure WA_PRUWC you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_PRUWC TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_PRUWC INTO WA_PRUWC. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.

*Conversion exit ALPHA, internal->external for field KOSTL CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_PRUWC-KOSTL IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_PRUWC-KOSTL.
WRITE:/ 'New Value:', ld_input.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_PRUWC_STR,
MASSN TYPE STRING,
MASSG TYPE STRING,
STAT1 TYPE STRING,
STAT2 TYPE STRING,
STAT3 TYPE STRING,
AKTIVJN TYPE STRING,
NGTGS TYPE STRING,
WERKS TYPE STRING,
BTRTL TYPE STRING,
KOSTL TYPE STRING,
PERSG TYPE STRING,
PERSK TYPE STRING,
ABART TYPE STRING,
PLANS TYPE STRING,
GSBER TYPE STRING,
VDSK1 TYPE STRING,
ANSVH TYPE STRING,
ORGEH TYPE STRING,
STELL TYPE STRING,
ZTERF TYPE STRING,
SCHKZ TYPE STRING,
EMPCT TYPE STRING,
BSGRD TYPE STRING,
TRFAR TYPE STRING,
TRFGB TYPE STRING,
TRFGR TYPE STRING,
TRFST TYPE STRING,
LGART TYPE STRING,
PERNR TYPE STRING,
CTTYP TYPE STRING,
PFWCN TYPE STRING,
PFWCC TYPE STRING,END OF T_EKKO_STR. DATA: WA_PRUWC_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_PRUWC_STR-MASSN sy-vline
WA_PRUWC_STR-MASSG sy-vline
WA_PRUWC_STR-STAT1 sy-vline
WA_PRUWC_STR-STAT2 sy-vline
WA_PRUWC_STR-STAT3 sy-vline
WA_PRUWC_STR-AKTIVJN sy-vline
WA_PRUWC_STR-NGTGS sy-vline
WA_PRUWC_STR-WERKS sy-vline
WA_PRUWC_STR-BTRTL sy-vline
WA_PRUWC_STR-KOSTL sy-vline
WA_PRUWC_STR-PERSG sy-vline
WA_PRUWC_STR-PERSK sy-vline
WA_PRUWC_STR-ABART sy-vline
WA_PRUWC_STR-PLANS sy-vline
WA_PRUWC_STR-GSBER sy-vline
WA_PRUWC_STR-VDSK1 sy-vline
WA_PRUWC_STR-ANSVH sy-vline
WA_PRUWC_STR-ORGEH sy-vline
WA_PRUWC_STR-STELL sy-vline
WA_PRUWC_STR-ZTERF sy-vline
WA_PRUWC_STR-SCHKZ sy-vline
WA_PRUWC_STR-EMPCT sy-vline
WA_PRUWC_STR-BSGRD sy-vline
WA_PRUWC_STR-TRFAR sy-vline
WA_PRUWC_STR-TRFGB sy-vline
WA_PRUWC_STR-TRFGR sy-vline
WA_PRUWC_STR-TRFST sy-vline
WA_PRUWC_STR-LGART sy-vline
WA_PRUWC_STR-PERNR sy-vline
WA_PRUWC_STR-CTTYP sy-vline
WA_PRUWC_STR-PFWCN sy-vline
WA_PRUWC_STR-PFWCC sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.