ABAP Select data from SAP table PRUAVP1_24 into internal table
Get Example source ABAP code based on a different SAP table
Below is a number of ABAP code snippets to demonstrate how to select data from SAP PRUAVP1_24 table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to PRUAVP1_24. See here for more generic Select statement tips.
Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.
There is also a full declaration of the PRUAVP1_24 table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.
DATA: IT_PRUAVP1_24 TYPE STANDARD TABLE OF PRUAVP1_24, WA_PRUAVP1_24 TYPE PRUAVP1_24, GD_STR TYPE STRING. DATA: lo_typedescr type REF TO cl_abap_typedescr. DATA: lv_fieldname type fieldname. FIELD-SYMBOLS: <FIELD> TYPE any. FIELD-SYMBOLS: <PRUAVP1_24> TYPE PRUAVP1_24. *Process all fields in table header/work area as string values PERFORM process_as_string_field_values CHANGING wa_PRUAVP1_24. SELECT * *restrict ABAP select to first 10 rows UP TO 10 ROWS FROM PRUAVP1_24 INTO TABLE IT_PRUAVP1_24. *Select data and declare internal table using in-line method @DATA *SELECT * * FROM PRUAVP1_24 * INTO TABLE @DATA(IT_PRUAVP1_242). *--Further methods of using ABAP code to select data from SAP database tables *You can also declare the header/work area using the in-line DATA declaration method READ TABLE IT_PRUAVP1_24 INDEX 1 INTO DATA(WA_PRUAVP1_242). *Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL LOOP AT IT_PRUAVP1_24 ASSIGNING <PRUAVP1_24>.*To update a field value using a field symbol simply change the value via the field symbol pointer
<PRUAVP1_24>-DISPLAY = 1.
<PRUAVP1_24>-STR24_010_4 = 1.
<PRUAVP1_24>-STR24_010_5 = 1.
<PRUAVP1_24>-STR24_010_6 = 1.
<PRUAVP1_24>-STR24_020_4 = 1.
ENDLOOP. LOOP AT IT_PRUAVP1_24 INTO WA_PRUAVP1_24. *Write horizonal line to screen report. WRITE:/ sy-uline. *Write selected data to screen/report before conversion. WRITE:/ sy-vline, WA_PRUAVP1_24-STR24_020_5, sy-vline,
WA_PRUAVP1_24-STR24_020_6, sy-vline,
WA_PRUAVP1_24-STR24_030_4, sy-vline,
WA_PRUAVP1_24-STR24_030_5, sy-vline,
WA_PRUAVP1_24-STR24_030_6, sy-vline,
WA_PRUAVP1_24-STR24_040_4, sy-vline.
ENDLOOP. *Add any further fields from structure WA_PRUAVP1_24 you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_PRUAVP1_24 TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_PRUAVP1_24 INTO WA_PRUAVP1_24. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_PRUAVP1_24_STR,
DISPLAY TYPE STRING,
STR24_010_4 TYPE STRING,
STR24_010_5 TYPE STRING,
STR24_010_6 TYPE STRING,
STR24_020_4 TYPE STRING,
STR24_020_5 TYPE STRING,
STR24_020_6 TYPE STRING,
STR24_030_4 TYPE STRING,
STR24_030_5 TYPE STRING,
STR24_030_6 TYPE STRING,
STR24_040_4 TYPE STRING,
STR24_040_5 TYPE STRING,
STR24_040_6 TYPE STRING,
STR24_050_4 TYPE STRING,
STR24_050_5 TYPE STRING,
STR24_050_6 TYPE STRING,
STR24_060_4 TYPE STRING,
STR24_060_5 TYPE STRING,
STR24_060_6 TYPE STRING,
STR24_070_4 TYPE STRING,
STR24_070_5 TYPE STRING,
STR24_070_6 TYPE STRING,
STR24_080_4 TYPE STRING,
STR24_080_5 TYPE STRING,
STR24_080_6 TYPE STRING,
DATE_24_1 TYPE STRING,
DATE_24_2 TYPE STRING,
DATE_24_3 TYPE STRING,
FIO_24 TYPE STRING,
RUK_INN TYPE STRING,
BUH_INN TYPE STRING,END OF T_EKKO_STR. DATA: WA_PRUAVP1_24_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_PRUAVP1_24_STR-DISPLAY sy-vline
WA_PRUAVP1_24_STR-STR24_010_4 sy-vline
WA_PRUAVP1_24_STR-STR24_010_5 sy-vline
WA_PRUAVP1_24_STR-STR24_010_6 sy-vline
WA_PRUAVP1_24_STR-STR24_020_4 sy-vline
WA_PRUAVP1_24_STR-STR24_020_5 sy-vline
WA_PRUAVP1_24_STR-STR24_020_6 sy-vline
WA_PRUAVP1_24_STR-STR24_030_4 sy-vline
WA_PRUAVP1_24_STR-STR24_030_5 sy-vline
WA_PRUAVP1_24_STR-STR24_030_6 sy-vline
WA_PRUAVP1_24_STR-STR24_040_4 sy-vline
WA_PRUAVP1_24_STR-STR24_040_5 sy-vline
WA_PRUAVP1_24_STR-STR24_040_6 sy-vline
WA_PRUAVP1_24_STR-STR24_050_4 sy-vline
WA_PRUAVP1_24_STR-STR24_050_5 sy-vline
WA_PRUAVP1_24_STR-STR24_050_6 sy-vline
WA_PRUAVP1_24_STR-STR24_060_4 sy-vline
WA_PRUAVP1_24_STR-STR24_060_5 sy-vline
WA_PRUAVP1_24_STR-STR24_060_6 sy-vline
WA_PRUAVP1_24_STR-STR24_070_4 sy-vline
WA_PRUAVP1_24_STR-STR24_070_5 sy-vline
WA_PRUAVP1_24_STR-STR24_070_6 sy-vline
WA_PRUAVP1_24_STR-STR24_080_4 sy-vline
WA_PRUAVP1_24_STR-STR24_080_5 sy-vline
WA_PRUAVP1_24_STR-STR24_080_6 sy-vline
WA_PRUAVP1_24_STR-DATE_24_1 sy-vline
WA_PRUAVP1_24_STR-DATE_24_2 sy-vline
WA_PRUAVP1_24_STR-DATE_24_3 sy-vline
WA_PRUAVP1_24_STR-FIO_24 sy-vline
WA_PRUAVP1_24_STR-RUK_INN sy-vline
WA_PRUAVP1_24_STR-BUH_INN sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.