ABAP Select data from SAP table PRU_PKMN_PCNT_SZV into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP PRU_PKMN_PCNT_SZV table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to PRU_PKMN_PCNT_SZV. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the PRU_PKMN_PCNT_SZV table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_PRU_PKMN_PCNT_SZV TYPE STANDARD TABLE OF PRU_PKMN_PCNT_SZV,
      WA_PRU_PKMN_PCNT_SZV TYPE PRU_PKMN_PCNT_SZV,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: <PRU_PKMN_PCNT_SZV> TYPE PRU_PKMN_PCNT_SZV.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_PRU_PKMN_PCNT_SZV.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM PRU_PKMN_PCNT_SZV
  INTO TABLE IT_PRU_PKMN_PCNT_SZV.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM PRU_PKMN_PCNT_SZV
*  INTO TABLE @DATA(IT_PRU_PKMN_PCNT_SZV2).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_PRU_PKMN_PCNT_SZV INDEX 1 INTO DATA(WA_PRU_PKMN_PCNT_SZV2).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_PRU_PKMN_PCNT_SZV ASSIGNING <PRU_PKMN_PCNT_SZV>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
<PRU_PKMN_PCNT_SZV>-P_ITYPE = 1.
<PRU_PKMN_PCNT_SZV>-P_KTYPE = 1.
<PRU_PKMN_PCNT_SZV>-ORG_T5Y9A = 1.
<PRU_PKMN_PCNT_SZV>-MANDT = 1.
<PRU_PKMN_PCNT_SZV>-SOORT = 1.
ENDLOOP.

LOOP AT IT_PRU_PKMN_PCNT_SZV INTO WA_PRU_PKMN_PCNT_SZV.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_PRU_PKMN_PCNT_SZV-JUPER, sy-vline,
WA_PRU_PKMN_PCNT_SZV-INSTL, sy-vline,
WA_PRU_PKMN_PCNT_SZV-OTYPE, sy-vline,
WA_PRU_PKMN_PCNT_SZV-OBJID, sy-vline,
WA_PRU_PKMN_PCNT_SZV-ENDDA, sy-vline,
WA_PRU_PKMN_PCNT_SZV-BEGDA, sy-vline.
ENDLOOP. *Add any further fields from structure WA_PRU_PKMN_PCNT_SZV you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_PRU_PKMN_PCNT_SZV TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_PRU_PKMN_PCNT_SZV INTO WA_PRU_PKMN_PCNT_SZV. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_PRU_PKMN_PCNT_SZV_STR,
P_ITYPE TYPE STRING,
P_KTYPE TYPE STRING,
ORG_T5Y9A TYPE STRING,
MANDT TYPE STRING,
SOORT TYPE STRING,
JUPER TYPE STRING,
INSTL TYPE STRING,
OTYPE TYPE STRING,
OBJID TYPE STRING,
ENDDA TYPE STRING,
BEGDA TYPE STRING,
KNAAM TYPE STRING,
LNAAM TYPE STRING,
STRAS TYPE STRING,
HSNMR TYPE STRING,
POSTA TYPE STRING,
BLDNG TYPE STRING,
LOCAT TYPE STRING,
PSTLZ TYPE STRING,
ORT01 TYPE STRING,
LAND1 TYPE STRING,
STATE TYPE STRING,
COUNC TYPE STRING,
TELNR TYPE STRING,
FAXNR TYPE STRING,
KPERS TYPE STRING,
ANSNR TYPE STRING,
REKNR TYPE STRING,
AFDLG TYPE STRING,
KPP00 TYPE STRING,
KDVID TYPE STRING,
KDOKP TYPE STRING,
KDOKD TYPE STRING,
KDOKH TYPE STRING,
KOKFS TYPE STRING,
REGNO TYPE STRING,
REGDT TYPE STRING,
REGOR TYPE STRING,
REGCD TYPE STRING,
OKATO TYPE STRING,
OKTMO TYPE STRING,
OKOPF TYPE STRING,
KOGRN TYPE STRING,
FSSRN TYPE STRING,
TAXRG TYPE STRING,
FSSCD TYPE STRING,
EGRUL TYPE STRING,
ORPRF TYPE STRING,
TFOMS TYPE STRING,
TXSRG TYPE STRING,
TXBRG TYPE STRING,
SHFSN TYPE STRING,
LOFSN TYPE STRING,
FSSNM TYPE STRING,
FSSCC TYPE STRING,
FSSHB TYPE STRING,
FSSKT TYPE STRING,
EMAIL TYPE STRING,
PLANCODE TYPE STRING,
PLANNAME TYPE STRING,
REGIONNAME TYPE STRING,
REGIONSOCR TYPE STRING,
AREANAME TYPE STRING,
AREASOCR TYPE STRING,
TOSP TYPE STRING,
FSSSC TYPE STRING,
YEAR TYPE STRING,
V_S TYPE STRING,
V_N TYPE STRING,
V_T TYPE STRING,
BNUM TYPE STRING,
NSZV42 TYPE STRING,
DPODP TYPE STRING,END OF T_EKKO_STR. DATA: WA_PRU_PKMN_PCNT_SZV_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_PRU_PKMN_PCNT_SZV_STR-P_ITYPE sy-vline
WA_PRU_PKMN_PCNT_SZV_STR-P_KTYPE sy-vline
WA_PRU_PKMN_PCNT_SZV_STR-ORG_T5Y9A sy-vline
WA_PRU_PKMN_PCNT_SZV_STR-MANDT sy-vline
WA_PRU_PKMN_PCNT_SZV_STR-SOORT sy-vline
WA_PRU_PKMN_PCNT_SZV_STR-JUPER sy-vline
WA_PRU_PKMN_PCNT_SZV_STR-INSTL sy-vline
WA_PRU_PKMN_PCNT_SZV_STR-OTYPE sy-vline
WA_PRU_PKMN_PCNT_SZV_STR-OBJID sy-vline
WA_PRU_PKMN_PCNT_SZV_STR-ENDDA sy-vline
WA_PRU_PKMN_PCNT_SZV_STR-BEGDA sy-vline
WA_PRU_PKMN_PCNT_SZV_STR-KNAAM sy-vline
WA_PRU_PKMN_PCNT_SZV_STR-LNAAM sy-vline
WA_PRU_PKMN_PCNT_SZV_STR-STRAS sy-vline
WA_PRU_PKMN_PCNT_SZV_STR-HSNMR sy-vline
WA_PRU_PKMN_PCNT_SZV_STR-POSTA sy-vline
WA_PRU_PKMN_PCNT_SZV_STR-BLDNG sy-vline
WA_PRU_PKMN_PCNT_SZV_STR-LOCAT sy-vline
WA_PRU_PKMN_PCNT_SZV_STR-PSTLZ sy-vline
WA_PRU_PKMN_PCNT_SZV_STR-ORT01 sy-vline
WA_PRU_PKMN_PCNT_SZV_STR-LAND1 sy-vline
WA_PRU_PKMN_PCNT_SZV_STR-STATE sy-vline
WA_PRU_PKMN_PCNT_SZV_STR-COUNC sy-vline
WA_PRU_PKMN_PCNT_SZV_STR-TELNR sy-vline
WA_PRU_PKMN_PCNT_SZV_STR-FAXNR sy-vline
WA_PRU_PKMN_PCNT_SZV_STR-KPERS sy-vline
WA_PRU_PKMN_PCNT_SZV_STR-ANSNR sy-vline
WA_PRU_PKMN_PCNT_SZV_STR-REKNR sy-vline
WA_PRU_PKMN_PCNT_SZV_STR-AFDLG sy-vline
WA_PRU_PKMN_PCNT_SZV_STR-KPP00 sy-vline
WA_PRU_PKMN_PCNT_SZV_STR-KDVID sy-vline
WA_PRU_PKMN_PCNT_SZV_STR-KDOKP sy-vline
WA_PRU_PKMN_PCNT_SZV_STR-KDOKD sy-vline
WA_PRU_PKMN_PCNT_SZV_STR-KDOKH sy-vline
WA_PRU_PKMN_PCNT_SZV_STR-KOKFS sy-vline
WA_PRU_PKMN_PCNT_SZV_STR-REGNO sy-vline
WA_PRU_PKMN_PCNT_SZV_STR-REGDT sy-vline
WA_PRU_PKMN_PCNT_SZV_STR-REGOR sy-vline
WA_PRU_PKMN_PCNT_SZV_STR-REGCD sy-vline
WA_PRU_PKMN_PCNT_SZV_STR-OKATO sy-vline
WA_PRU_PKMN_PCNT_SZV_STR-OKTMO sy-vline
WA_PRU_PKMN_PCNT_SZV_STR-OKOPF sy-vline
WA_PRU_PKMN_PCNT_SZV_STR-KOGRN sy-vline
WA_PRU_PKMN_PCNT_SZV_STR-FSSRN sy-vline
WA_PRU_PKMN_PCNT_SZV_STR-TAXRG sy-vline
WA_PRU_PKMN_PCNT_SZV_STR-FSSCD sy-vline
WA_PRU_PKMN_PCNT_SZV_STR-EGRUL sy-vline
WA_PRU_PKMN_PCNT_SZV_STR-ORPRF sy-vline
WA_PRU_PKMN_PCNT_SZV_STR-TFOMS sy-vline
WA_PRU_PKMN_PCNT_SZV_STR-TXSRG sy-vline
WA_PRU_PKMN_PCNT_SZV_STR-TXBRG sy-vline
WA_PRU_PKMN_PCNT_SZV_STR-SHFSN sy-vline
WA_PRU_PKMN_PCNT_SZV_STR-LOFSN sy-vline
WA_PRU_PKMN_PCNT_SZV_STR-FSSNM sy-vline
WA_PRU_PKMN_PCNT_SZV_STR-FSSCC sy-vline
WA_PRU_PKMN_PCNT_SZV_STR-FSSHB sy-vline
WA_PRU_PKMN_PCNT_SZV_STR-FSSKT sy-vline
WA_PRU_PKMN_PCNT_SZV_STR-EMAIL sy-vline
WA_PRU_PKMN_PCNT_SZV_STR-PLANCODE sy-vline
WA_PRU_PKMN_PCNT_SZV_STR-PLANNAME sy-vline
WA_PRU_PKMN_PCNT_SZV_STR-REGIONNAME sy-vline
WA_PRU_PKMN_PCNT_SZV_STR-REGIONSOCR sy-vline
WA_PRU_PKMN_PCNT_SZV_STR-AREANAME sy-vline
WA_PRU_PKMN_PCNT_SZV_STR-AREASOCR sy-vline
WA_PRU_PKMN_PCNT_SZV_STR-TOSP sy-vline
WA_PRU_PKMN_PCNT_SZV_STR-FSSSC sy-vline
WA_PRU_PKMN_PCNT_SZV_STR-YEAR sy-vline
WA_PRU_PKMN_PCNT_SZV_STR-V_S sy-vline
WA_PRU_PKMN_PCNT_SZV_STR-V_N sy-vline
WA_PRU_PKMN_PCNT_SZV_STR-V_T sy-vline
WA_PRU_PKMN_PCNT_SZV_STR-BNUM sy-vline
WA_PRU_PKMN_PCNT_SZV_STR-NSZV42 sy-vline
WA_PRU_PKMN_PCNT_SZV_STR-DPODP sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.