ABAP Select data from SAP table PRU_DED_LGART_CE into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP PRU_DED_LGART_CE table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to PRU_DED_LGART_CE. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the PRU_DED_LGART_CE table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_PRU_DED_LGART_CE TYPE STANDARD TABLE OF PRU_DED_LGART_CE,
      WA_PRU_DED_LGART_CE TYPE PRU_DED_LGART_CE,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: <PRU_DED_LGART_CE> TYPE PRU_DED_LGART_CE.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_PRU_DED_LGART_CE.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM PRU_DED_LGART_CE
  INTO TABLE IT_PRU_DED_LGART_CE.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM PRU_DED_LGART_CE
*  INTO TABLE @DATA(IT_PRU_DED_LGART_CE2).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_PRU_DED_LGART_CE INDEX 1 INTO DATA(WA_PRU_DED_LGART_CE2).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_PRU_DED_LGART_CE ASSIGNING <PRU_DED_LGART_CE>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
<PRU_DED_LGART_CE>-ABART = 1.
<PRU_DED_LGART_CE>-LGART = 1.
<PRU_DED_LGART_CE>-APZNR = 1.
<PRU_DED_LGART_CE>-CNTR1 = 1.
<PRU_DED_LGART_CE>-CNTR2 = 1.
ENDLOOP.

LOOP AT IT_PRU_DED_LGART_CE INTO WA_PRU_DED_LGART_CE.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_PRU_DED_LGART_CE-CNTR3, sy-vline,
WA_PRU_DED_LGART_CE-ALZNR, sy-vline,
WA_PRU_DED_LGART_CE-C1ZNR, sy-vline,
WA_PRU_DED_LGART_CE-BTZNR, sy-vline,
WA_PRU_DED_LGART_CE-ABZNR, sy-vline,
WA_PRU_DED_LGART_CE-V0TYP, sy-vline.
ENDLOOP. *Add any further fields from structure WA_PRU_DED_LGART_CE you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_PRU_DED_LGART_CE TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_PRU_DED_LGART_CE INTO WA_PRU_DED_LGART_CE. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_PRU_DED_LGART_CE_STR,
ABART TYPE STRING,
LGART TYPE STRING,
APZNR TYPE STRING,
CNTR1 TYPE STRING,
CNTR2 TYPE STRING,
CNTR3 TYPE STRING,
ALZNR TYPE STRING,
C1ZNR TYPE STRING,
BTZNR TYPE STRING,
ABZNR TYPE STRING,
V0TYP TYPE STRING,
V0ZNR TYPE STRING,
ZEINH TYPE STRING,
BETPE TYPE STRING,
ANZHL TYPE STRING,
BETRG TYPE STRING,
RTE_CURR TYPE STRING,
AMT_CURR TYPE STRING,
PRIO TYPE STRING,
POSSIBLE TYPE STRING,
WEIGH TYPE STRING,
PERNR TYPE STRING,
ENNUM TYPE STRING,
GPRIO TYPE STRING,END OF T_EKKO_STR. DATA: WA_PRU_DED_LGART_CE_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_PRU_DED_LGART_CE_STR-ABART sy-vline
WA_PRU_DED_LGART_CE_STR-LGART sy-vline
WA_PRU_DED_LGART_CE_STR-APZNR sy-vline
WA_PRU_DED_LGART_CE_STR-CNTR1 sy-vline
WA_PRU_DED_LGART_CE_STR-CNTR2 sy-vline
WA_PRU_DED_LGART_CE_STR-CNTR3 sy-vline
WA_PRU_DED_LGART_CE_STR-ALZNR sy-vline
WA_PRU_DED_LGART_CE_STR-C1ZNR sy-vline
WA_PRU_DED_LGART_CE_STR-BTZNR sy-vline
WA_PRU_DED_LGART_CE_STR-ABZNR sy-vline
WA_PRU_DED_LGART_CE_STR-V0TYP sy-vline
WA_PRU_DED_LGART_CE_STR-V0ZNR sy-vline
WA_PRU_DED_LGART_CE_STR-ZEINH sy-vline
WA_PRU_DED_LGART_CE_STR-BETPE sy-vline
WA_PRU_DED_LGART_CE_STR-ANZHL sy-vline
WA_PRU_DED_LGART_CE_STR-BETRG sy-vline
WA_PRU_DED_LGART_CE_STR-RTE_CURR sy-vline
WA_PRU_DED_LGART_CE_STR-AMT_CURR sy-vline
WA_PRU_DED_LGART_CE_STR-PRIO sy-vline
WA_PRU_DED_LGART_CE_STR-POSSIBLE sy-vline
WA_PRU_DED_LGART_CE_STR-WEIGH sy-vline
WA_PRU_DED_LGART_CE_STR-PERNR sy-vline
WA_PRU_DED_LGART_CE_STR-ENNUM sy-vline
WA_PRU_DED_LGART_CE_STR-GPRIO sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.