ABAP Select data from SAP table PRU_4FSS_T8_V4 into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP PRU_4FSS_T8_V4 table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to PRU_4FSS_T8_V4. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the PRU_4FSS_T8_V4 table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_PRU_4FSS_T8_V4 TYPE STANDARD TABLE OF PRU_4FSS_T8_V4,
      WA_PRU_4FSS_T8_V4 TYPE PRU_4FSS_T8_V4,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: <PRU_4FSS_T8_V4> TYPE PRU_4FSS_T8_V4.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_PRU_4FSS_T8_V4.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM PRU_4FSS_T8_V4
  INTO TABLE IT_PRU_4FSS_T8_V4.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM PRU_4FSS_T8_V4
*  INTO TABLE @DATA(IT_PRU_4FSS_T8_V42).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_PRU_4FSS_T8_V4 INDEX 1 INTO DATA(WA_PRU_4FSS_T8_V42).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_PRU_4FSS_T8_V4 ASSIGNING <PRU_4FSS_T8_V4>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
<PRU_4FSS_T8_V4>-T813 = 1.
<PRU_4FSS_T8_V4>-T814 = 1.
<PRU_4FSS_T8_V4>-T823 = 1.
<PRU_4FSS_T8_V4>-T824 = 1.
<PRU_4FSS_T8_V4>-T833 = 1.
ENDLOOP.

LOOP AT IT_PRU_4FSS_T8_V4 INTO WA_PRU_4FSS_T8_V4.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_PRU_4FSS_T8_V4-T834, sy-vline,
WA_PRU_4FSS_T8_V4-T843, sy-vline,
WA_PRU_4FSS_T8_V4-T844, sy-vline,
WA_PRU_4FSS_T8_V4-T853, sy-vline,
WA_PRU_4FSS_T8_V4-T854, sy-vline,
WA_PRU_4FSS_T8_V4-T863, sy-vline.
ENDLOOP. *Add any further fields from structure WA_PRU_4FSS_T8_V4 you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_PRU_4FSS_T8_V4 TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_PRU_4FSS_T8_V4 INTO WA_PRU_4FSS_T8_V4. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_PRU_4FSS_T8_V4_STR,
T813 TYPE STRING,
T814 TYPE STRING,
T823 TYPE STRING,
T824 TYPE STRING,
T833 TYPE STRING,
T834 TYPE STRING,
T843 TYPE STRING,
T844 TYPE STRING,
T853 TYPE STRING,
T854 TYPE STRING,
T863 TYPE STRING,
T864 TYPE STRING,
T873 TYPE STRING,
T874 TYPE STRING,
T883 TYPE STRING,
T884 TYPE STRING,
T89 TYPE STRING,
T8A TYPE STRING,
T8FLG TYPE STRING,
T8114 TYPE STRING,END OF T_EKKO_STR. DATA: WA_PRU_4FSS_T8_V4_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_PRU_4FSS_T8_V4_STR-T813 sy-vline
WA_PRU_4FSS_T8_V4_STR-T814 sy-vline
WA_PRU_4FSS_T8_V4_STR-T823 sy-vline
WA_PRU_4FSS_T8_V4_STR-T824 sy-vline
WA_PRU_4FSS_T8_V4_STR-T833 sy-vline
WA_PRU_4FSS_T8_V4_STR-T834 sy-vline
WA_PRU_4FSS_T8_V4_STR-T843 sy-vline
WA_PRU_4FSS_T8_V4_STR-T844 sy-vline
WA_PRU_4FSS_T8_V4_STR-T853 sy-vline
WA_PRU_4FSS_T8_V4_STR-T854 sy-vline
WA_PRU_4FSS_T8_V4_STR-T863 sy-vline
WA_PRU_4FSS_T8_V4_STR-T864 sy-vline
WA_PRU_4FSS_T8_V4_STR-T873 sy-vline
WA_PRU_4FSS_T8_V4_STR-T874 sy-vline
WA_PRU_4FSS_T8_V4_STR-T883 sy-vline
WA_PRU_4FSS_T8_V4_STR-T884 sy-vline
WA_PRU_4FSS_T8_V4_STR-T89 sy-vline
WA_PRU_4FSS_T8_V4_STR-T8A sy-vline
WA_PRU_4FSS_T8_V4_STR-T8FLG sy-vline
WA_PRU_4FSS_T8_V4_STR-T8114 sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.