ABAP Select data from SAP table PRU_4FSS_T7_V3 into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP PRU_4FSS_T7_V3 table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to PRU_4FSS_T7_V3. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the PRU_4FSS_T7_V3 table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_PRU_4FSS_T7_V3 TYPE STANDARD TABLE OF PRU_4FSS_T7_V3,
      WA_PRU_4FSS_T7_V3 TYPE PRU_4FSS_T7_V3,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: <PRU_4FSS_T7_V3> TYPE PRU_4FSS_T7_V3.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_PRU_4FSS_T7_V3.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM PRU_4FSS_T7_V3
  INTO TABLE IT_PRU_4FSS_T7_V3.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM PRU_4FSS_T7_V3
*  INTO TABLE @DATA(IT_PRU_4FSS_T7_V32).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_PRU_4FSS_T7_V3 INDEX 1 INTO DATA(WA_PRU_4FSS_T7_V32).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_PRU_4FSS_T7_V3 ASSIGNING <PRU_4FSS_T7_V3>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
<PRU_4FSS_T7_V3>-T7011 = 1.
<PRU_4FSS_T7_V3>-T7013 = 1.
<PRU_4FSS_T7_V3>-T7014 = 1.
<PRU_4FSS_T7_V3>-T7015 = 1.
<PRU_4FSS_T7_V3>-T7021 = 1.
ENDLOOP.

LOOP AT IT_PRU_4FSS_T7_V3 INTO WA_PRU_4FSS_T7_V3.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_PRU_4FSS_T7_V3-T7023, sy-vline,
WA_PRU_4FSS_T7_V3-T7024, sy-vline,
WA_PRU_4FSS_T7_V3-T7025, sy-vline,
WA_PRU_4FSS_T7_V3-T7033, sy-vline,
WA_PRU_4FSS_T7_V3-T7034, sy-vline,
WA_PRU_4FSS_T7_V3-T7035, sy-vline.
ENDLOOP. *Add any further fields from structure WA_PRU_4FSS_T7_V3 you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_PRU_4FSS_T7_V3 TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_PRU_4FSS_T7_V3 INTO WA_PRU_4FSS_T7_V3. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_PRU_4FSS_T7_V3_STR,
T7011 TYPE STRING,
T7013 TYPE STRING,
T7014 TYPE STRING,
T7015 TYPE STRING,
T7021 TYPE STRING,
T7023 TYPE STRING,
T7024 TYPE STRING,
T7025 TYPE STRING,
T7033 TYPE STRING,
T7034 TYPE STRING,
T7035 TYPE STRING,
T7043 TYPE STRING,
T7044 TYPE STRING,
T7045 TYPE STRING,
T7053 TYPE STRING,
T7054 TYPE STRING,
T7063 TYPE STRING,
T7064 TYPE STRING,
T7071 TYPE STRING,
T7073 TYPE STRING,
T7074 TYPE STRING,
T7075 TYPE STRING,
T7081 TYPE STRING,
T7083 TYPE STRING,
T7084 TYPE STRING,
T7085 TYPE STRING,
T7091 TYPE STRING,
T7093 TYPE STRING,
T7094 TYPE STRING,
T7095 TYPE STRING,
T7101 TYPE STRING,
T7103 TYPE STRING,
T7104 TYPE STRING,
T7105 TYPE STRING,
T7111 TYPE STRING,
T7113 TYPE STRING,
T7114 TYPE STRING,
T7115 TYPE STRING,
T7121 TYPE STRING,
T7123 TYPE STRING,
T7124 TYPE STRING,
T7125 TYPE STRING,
T7131 TYPE STRING,
T7133 TYPE STRING,
T7134 TYPE STRING,
T7135 TYPE STRING,
T7143 TYPE STRING,
T7144 TYPE STRING,
T7145 TYPE STRING,
T7153 TYPE STRING,
T7154 TYPE STRING,
T7155 TYPE STRING,
T7163 TYPE STRING,
T7164 TYPE STRING,
T7165 TYPE STRING,END OF T_EKKO_STR. DATA: WA_PRU_4FSS_T7_V3_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_PRU_4FSS_T7_V3_STR-T7011 sy-vline
WA_PRU_4FSS_T7_V3_STR-T7013 sy-vline
WA_PRU_4FSS_T7_V3_STR-T7014 sy-vline
WA_PRU_4FSS_T7_V3_STR-T7015 sy-vline
WA_PRU_4FSS_T7_V3_STR-T7021 sy-vline
WA_PRU_4FSS_T7_V3_STR-T7023 sy-vline
WA_PRU_4FSS_T7_V3_STR-T7024 sy-vline
WA_PRU_4FSS_T7_V3_STR-T7025 sy-vline
WA_PRU_4FSS_T7_V3_STR-T7033 sy-vline
WA_PRU_4FSS_T7_V3_STR-T7034 sy-vline
WA_PRU_4FSS_T7_V3_STR-T7035 sy-vline
WA_PRU_4FSS_T7_V3_STR-T7043 sy-vline
WA_PRU_4FSS_T7_V3_STR-T7044 sy-vline
WA_PRU_4FSS_T7_V3_STR-T7045 sy-vline
WA_PRU_4FSS_T7_V3_STR-T7053 sy-vline
WA_PRU_4FSS_T7_V3_STR-T7054 sy-vline
WA_PRU_4FSS_T7_V3_STR-T7063 sy-vline
WA_PRU_4FSS_T7_V3_STR-T7064 sy-vline
WA_PRU_4FSS_T7_V3_STR-T7071 sy-vline
WA_PRU_4FSS_T7_V3_STR-T7073 sy-vline
WA_PRU_4FSS_T7_V3_STR-T7074 sy-vline
WA_PRU_4FSS_T7_V3_STR-T7075 sy-vline
WA_PRU_4FSS_T7_V3_STR-T7081 sy-vline
WA_PRU_4FSS_T7_V3_STR-T7083 sy-vline
WA_PRU_4FSS_T7_V3_STR-T7084 sy-vline
WA_PRU_4FSS_T7_V3_STR-T7085 sy-vline
WA_PRU_4FSS_T7_V3_STR-T7091 sy-vline
WA_PRU_4FSS_T7_V3_STR-T7093 sy-vline
WA_PRU_4FSS_T7_V3_STR-T7094 sy-vline
WA_PRU_4FSS_T7_V3_STR-T7095 sy-vline
WA_PRU_4FSS_T7_V3_STR-T7101 sy-vline
WA_PRU_4FSS_T7_V3_STR-T7103 sy-vline
WA_PRU_4FSS_T7_V3_STR-T7104 sy-vline
WA_PRU_4FSS_T7_V3_STR-T7105 sy-vline
WA_PRU_4FSS_T7_V3_STR-T7111 sy-vline
WA_PRU_4FSS_T7_V3_STR-T7113 sy-vline
WA_PRU_4FSS_T7_V3_STR-T7114 sy-vline
WA_PRU_4FSS_T7_V3_STR-T7115 sy-vline
WA_PRU_4FSS_T7_V3_STR-T7121 sy-vline
WA_PRU_4FSS_T7_V3_STR-T7123 sy-vline
WA_PRU_4FSS_T7_V3_STR-T7124 sy-vline
WA_PRU_4FSS_T7_V3_STR-T7125 sy-vline
WA_PRU_4FSS_T7_V3_STR-T7131 sy-vline
WA_PRU_4FSS_T7_V3_STR-T7133 sy-vline
WA_PRU_4FSS_T7_V3_STR-T7134 sy-vline
WA_PRU_4FSS_T7_V3_STR-T7135 sy-vline
WA_PRU_4FSS_T7_V3_STR-T7143 sy-vline
WA_PRU_4FSS_T7_V3_STR-T7144 sy-vline
WA_PRU_4FSS_T7_V3_STR-T7145 sy-vline
WA_PRU_4FSS_T7_V3_STR-T7153 sy-vline
WA_PRU_4FSS_T7_V3_STR-T7154 sy-vline
WA_PRU_4FSS_T7_V3_STR-T7155 sy-vline
WA_PRU_4FSS_T7_V3_STR-T7163 sy-vline
WA_PRU_4FSS_T7_V3_STR-T7164 sy-vline
WA_PRU_4FSS_T7_V3_STR-T7165 sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.