ABAP Select data from SAP table PRU_4FSS_T6_V1 into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP PRU_4FSS_T6_V1 table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to PRU_4FSS_T6_V1. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the PRU_4FSS_T6_V1 table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_PRU_4FSS_T6_V1 TYPE STANDARD TABLE OF PRU_4FSS_T6_V1,
      WA_PRU_4FSS_T6_V1 TYPE PRU_4FSS_T6_V1,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: <PRU_4FSS_T6_V1> TYPE PRU_4FSS_T6_V1.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_PRU_4FSS_T6_V1.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM PRU_4FSS_T6_V1
  INTO TABLE IT_PRU_4FSS_T6_V1.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM PRU_4FSS_T6_V1
*  INTO TABLE @DATA(IT_PRU_4FSS_T6_V12).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_PRU_4FSS_T6_V1 INDEX 1 INTO DATA(WA_PRU_4FSS_T6_V12).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_PRU_4FSS_T6_V1 ASSIGNING <PRU_4FSS_T6_V1>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
<PRU_4FSS_T6_V1>-T6011 = 1.
<PRU_4FSS_T6_V1>-T6013 = 1.
<PRU_4FSS_T6_V1>-T6014 = 1.
<PRU_4FSS_T6_V1>-T6015 = 1.
<PRU_4FSS_T6_V1>-T6021 = 1.
ENDLOOP.

LOOP AT IT_PRU_4FSS_T6_V1 INTO WA_PRU_4FSS_T6_V1.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_PRU_4FSS_T6_V1-T6023, sy-vline,
WA_PRU_4FSS_T6_V1-T6024, sy-vline,
WA_PRU_4FSS_T6_V1-T6025, sy-vline,
WA_PRU_4FSS_T6_V1-T602R, sy-vline,
WA_PRU_4FSS_T6_V1-T6033, sy-vline,
WA_PRU_4FSS_T6_V1-T6034, sy-vline.
ENDLOOP. *Add any further fields from structure WA_PRU_4FSS_T6_V1 you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_PRU_4FSS_T6_V1 TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_PRU_4FSS_T6_V1 INTO WA_PRU_4FSS_T6_V1. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_PRU_4FSS_T6_V1_STR,
T6011 TYPE STRING,
T6013 TYPE STRING,
T6014 TYPE STRING,
T6015 TYPE STRING,
T6021 TYPE STRING,
T6023 TYPE STRING,
T6024 TYPE STRING,
T6025 TYPE STRING,
T602R TYPE STRING,
T6033 TYPE STRING,
T6034 TYPE STRING,
T6035 TYPE STRING,
T6043 TYPE STRING,
T6044 TYPE STRING,
T6045 TYPE STRING,
T6051 TYPE STRING,
T6053 TYPE STRING,
T6054 TYPE STRING,
T6055 TYPE STRING,
T605R TYPE STRING,
T6061 TYPE STRING,
T6063 TYPE STRING,
T6064 TYPE STRING,
T6065 TYPE STRING,
T6071 TYPE STRING,
T6073 TYPE STRING,
T6074 TYPE STRING,
T6075 TYPE STRING,
T6083 TYPE STRING,
T6084 TYPE STRING,
T6093 TYPE STRING,
T6094 TYPE STRING,
T6095 TYPE STRING,
T6101 TYPE STRING,
T6103 TYPE STRING,
T6104 TYPE STRING,
T6113 TYPE STRING,
T6114 TYPE STRING,
T6123 TYPE STRING,
T6124 TYPE STRING,
T6133 TYPE STRING,
T6134 TYPE STRING,
T6135 TYPE STRING,
T6143 TYPE STRING,
T6141 TYPE STRING,
T6144 TYPE STRING,
T6153 TYPE STRING,
T6154 TYPE STRING,
T6163 TYPE STRING,
T6164 TYPE STRING,
T6165 TYPE STRING,
T6YAR TYPE STRING,
T6173 TYPE STRING,
T6174 TYPE STRING,
T6194 TYPE STRING,
T6204 TYPE STRING,
T6205 TYPE STRING,END OF T_EKKO_STR. DATA: WA_PRU_4FSS_T6_V1_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_PRU_4FSS_T6_V1_STR-T6011 sy-vline
WA_PRU_4FSS_T6_V1_STR-T6013 sy-vline
WA_PRU_4FSS_T6_V1_STR-T6014 sy-vline
WA_PRU_4FSS_T6_V1_STR-T6015 sy-vline
WA_PRU_4FSS_T6_V1_STR-T6021 sy-vline
WA_PRU_4FSS_T6_V1_STR-T6023 sy-vline
WA_PRU_4FSS_T6_V1_STR-T6024 sy-vline
WA_PRU_4FSS_T6_V1_STR-T6025 sy-vline
WA_PRU_4FSS_T6_V1_STR-T602R sy-vline
WA_PRU_4FSS_T6_V1_STR-T6033 sy-vline
WA_PRU_4FSS_T6_V1_STR-T6034 sy-vline
WA_PRU_4FSS_T6_V1_STR-T6035 sy-vline
WA_PRU_4FSS_T6_V1_STR-T6043 sy-vline
WA_PRU_4FSS_T6_V1_STR-T6044 sy-vline
WA_PRU_4FSS_T6_V1_STR-T6045 sy-vline
WA_PRU_4FSS_T6_V1_STR-T6051 sy-vline
WA_PRU_4FSS_T6_V1_STR-T6053 sy-vline
WA_PRU_4FSS_T6_V1_STR-T6054 sy-vline
WA_PRU_4FSS_T6_V1_STR-T6055 sy-vline
WA_PRU_4FSS_T6_V1_STR-T605R sy-vline
WA_PRU_4FSS_T6_V1_STR-T6061 sy-vline
WA_PRU_4FSS_T6_V1_STR-T6063 sy-vline
WA_PRU_4FSS_T6_V1_STR-T6064 sy-vline
WA_PRU_4FSS_T6_V1_STR-T6065 sy-vline
WA_PRU_4FSS_T6_V1_STR-T6071 sy-vline
WA_PRU_4FSS_T6_V1_STR-T6073 sy-vline
WA_PRU_4FSS_T6_V1_STR-T6074 sy-vline
WA_PRU_4FSS_T6_V1_STR-T6075 sy-vline
WA_PRU_4FSS_T6_V1_STR-T6083 sy-vline
WA_PRU_4FSS_T6_V1_STR-T6084 sy-vline
WA_PRU_4FSS_T6_V1_STR-T6093 sy-vline
WA_PRU_4FSS_T6_V1_STR-T6094 sy-vline
WA_PRU_4FSS_T6_V1_STR-T6095 sy-vline
WA_PRU_4FSS_T6_V1_STR-T6101 sy-vline
WA_PRU_4FSS_T6_V1_STR-T6103 sy-vline
WA_PRU_4FSS_T6_V1_STR-T6104 sy-vline
WA_PRU_4FSS_T6_V1_STR-T6113 sy-vline
WA_PRU_4FSS_T6_V1_STR-T6114 sy-vline
WA_PRU_4FSS_T6_V1_STR-T6123 sy-vline
WA_PRU_4FSS_T6_V1_STR-T6124 sy-vline
WA_PRU_4FSS_T6_V1_STR-T6133 sy-vline
WA_PRU_4FSS_T6_V1_STR-T6134 sy-vline
WA_PRU_4FSS_T6_V1_STR-T6135 sy-vline
WA_PRU_4FSS_T6_V1_STR-T6143 sy-vline
WA_PRU_4FSS_T6_V1_STR-T6141 sy-vline
WA_PRU_4FSS_T6_V1_STR-T6144 sy-vline
WA_PRU_4FSS_T6_V1_STR-T6153 sy-vline
WA_PRU_4FSS_T6_V1_STR-T6154 sy-vline
WA_PRU_4FSS_T6_V1_STR-T6163 sy-vline
WA_PRU_4FSS_T6_V1_STR-T6164 sy-vline
WA_PRU_4FSS_T6_V1_STR-T6165 sy-vline
WA_PRU_4FSS_T6_V1_STR-T6YAR sy-vline
WA_PRU_4FSS_T6_V1_STR-T6173 sy-vline
WA_PRU_4FSS_T6_V1_STR-T6174 sy-vline
WA_PRU_4FSS_T6_V1_STR-T6194 sy-vline
WA_PRU_4FSS_T6_V1_STR-T6204 sy-vline
WA_PRU_4FSS_T6_V1_STR-T6205 sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.