ABAP Select data from SAP table PRU_4FSS_T3_V1 into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP PRU_4FSS_T3_V1 table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to PRU_4FSS_T3_V1. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the PRU_4FSS_T3_V1 table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_PRU_4FSS_T3_V1 TYPE STANDARD TABLE OF PRU_4FSS_T3_V1,
      WA_PRU_4FSS_T3_V1 TYPE PRU_4FSS_T3_V1,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: <PRU_4FSS_T3_V1> TYPE PRU_4FSS_T3_V1.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_PRU_4FSS_T3_V1.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM PRU_4FSS_T3_V1
  INTO TABLE IT_PRU_4FSS_T3_V1.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM PRU_4FSS_T3_V1
*  INTO TABLE @DATA(IT_PRU_4FSS_T3_V12).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_PRU_4FSS_T3_V1 INDEX 1 INTO DATA(WA_PRU_4FSS_T3_V12).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_PRU_4FSS_T3_V1 ASSIGNING <PRU_4FSS_T3_V1>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
<PRU_4FSS_T3_V1>-T3011 = 1.
<PRU_4FSS_T3_V1>-T3013 = 1.
<PRU_4FSS_T3_V1>-T3014 = 1.
<PRU_4FSS_T3_V1>-T3015 = 1.
<PRU_4FSS_T3_V1>-T3021 = 1.
ENDLOOP.

LOOP AT IT_PRU_4FSS_T3_V1 INTO WA_PRU_4FSS_T3_V1.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_PRU_4FSS_T3_V1-T3023, sy-vline,
WA_PRU_4FSS_T3_V1-T3024, sy-vline,
WA_PRU_4FSS_T3_V1-T3025, sy-vline,
WA_PRU_4FSS_T3_V1-T302R, sy-vline,
WA_PRU_4FSS_T3_V1-T3033, sy-vline,
WA_PRU_4FSS_T3_V1-T3034, sy-vline.
ENDLOOP. *Add any further fields from structure WA_PRU_4FSS_T3_V1 you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_PRU_4FSS_T3_V1 TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_PRU_4FSS_T3_V1 INTO WA_PRU_4FSS_T3_V1. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_PRU_4FSS_T3_V1_STR,
T3011 TYPE STRING,
T3013 TYPE STRING,
T3014 TYPE STRING,
T3015 TYPE STRING,
T3021 TYPE STRING,
T3023 TYPE STRING,
T3024 TYPE STRING,
T3025 TYPE STRING,
T302R TYPE STRING,
T3033 TYPE STRING,
T3034 TYPE STRING,
T3035 TYPE STRING,
T3043 TYPE STRING,
T3044 TYPE STRING,
T3045 TYPE STRING,
T3051 TYPE STRING,
T3053 TYPE STRING,
T3054 TYPE STRING,
T3055 TYPE STRING,
T3061 TYPE STRING,
T3063 TYPE STRING,
T3064 TYPE STRING,
T3065 TYPE STRING,
T3071 TYPE STRING,
T3073 TYPE STRING,
T3074 TYPE STRING,
T3075 TYPE STRING,
T3081 TYPE STRING,
T3083 TYPE STRING,
T3084 TYPE STRING,
T3085 TYPE STRING,
T3091 TYPE STRING,
T3093 TYPE STRING,
T3094 TYPE STRING,
T3095 TYPE STRING,
T3101 TYPE STRING,
T3103 TYPE STRING,
T3104 TYPE STRING,
T3105 TYPE STRING,
T3111 TYPE STRING,
T3113 TYPE STRING,
T3114 TYPE STRING,
T3115 TYPE STRING,
T3123 TYPE STRING,
T3124 TYPE STRING,
T3133 TYPE STRING,
T3134 TYPE STRING,
T3135 TYPE STRING,
T3143 TYPE STRING,
T3144 TYPE STRING,
T3153 TYPE STRING,
T3154 TYPE STRING,
T3163 TYPE STRING,
T3164 TYPE STRING,
T3165 TYPE STRING,
T3YAR TYPE STRING,
T3174 TYPE STRING,
T3175 TYPE STRING,
T3181 TYPE STRING,
T3183 TYPE STRING,
T3184 TYPE STRING,
T3193 TYPE STRING,
T3194 TYPE STRING,
T3203 TYPE STRING,
T3204 TYPE STRING,
T3213 TYPE STRING,
T3214 TYPE STRING,
T3234 TYPE STRING,
T3244 TYPE STRING,
T3245 TYPE STRING,
T3SN1 TYPE STRING,
T3SN2 TYPE STRING,
T3SN3 TYPE STRING,
T3SN4 TYPE STRING,END OF T_EKKO_STR. DATA: WA_PRU_4FSS_T3_V1_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_PRU_4FSS_T3_V1_STR-T3011 sy-vline
WA_PRU_4FSS_T3_V1_STR-T3013 sy-vline
WA_PRU_4FSS_T3_V1_STR-T3014 sy-vline
WA_PRU_4FSS_T3_V1_STR-T3015 sy-vline
WA_PRU_4FSS_T3_V1_STR-T3021 sy-vline
WA_PRU_4FSS_T3_V1_STR-T3023 sy-vline
WA_PRU_4FSS_T3_V1_STR-T3024 sy-vline
WA_PRU_4FSS_T3_V1_STR-T3025 sy-vline
WA_PRU_4FSS_T3_V1_STR-T302R sy-vline
WA_PRU_4FSS_T3_V1_STR-T3033 sy-vline
WA_PRU_4FSS_T3_V1_STR-T3034 sy-vline
WA_PRU_4FSS_T3_V1_STR-T3035 sy-vline
WA_PRU_4FSS_T3_V1_STR-T3043 sy-vline
WA_PRU_4FSS_T3_V1_STR-T3044 sy-vline
WA_PRU_4FSS_T3_V1_STR-T3045 sy-vline
WA_PRU_4FSS_T3_V1_STR-T3051 sy-vline
WA_PRU_4FSS_T3_V1_STR-T3053 sy-vline
WA_PRU_4FSS_T3_V1_STR-T3054 sy-vline
WA_PRU_4FSS_T3_V1_STR-T3055 sy-vline
WA_PRU_4FSS_T3_V1_STR-T3061 sy-vline
WA_PRU_4FSS_T3_V1_STR-T3063 sy-vline
WA_PRU_4FSS_T3_V1_STR-T3064 sy-vline
WA_PRU_4FSS_T3_V1_STR-T3065 sy-vline
WA_PRU_4FSS_T3_V1_STR-T3071 sy-vline
WA_PRU_4FSS_T3_V1_STR-T3073 sy-vline
WA_PRU_4FSS_T3_V1_STR-T3074 sy-vline
WA_PRU_4FSS_T3_V1_STR-T3075 sy-vline
WA_PRU_4FSS_T3_V1_STR-T3081 sy-vline
WA_PRU_4FSS_T3_V1_STR-T3083 sy-vline
WA_PRU_4FSS_T3_V1_STR-T3084 sy-vline
WA_PRU_4FSS_T3_V1_STR-T3085 sy-vline
WA_PRU_4FSS_T3_V1_STR-T3091 sy-vline
WA_PRU_4FSS_T3_V1_STR-T3093 sy-vline
WA_PRU_4FSS_T3_V1_STR-T3094 sy-vline
WA_PRU_4FSS_T3_V1_STR-T3095 sy-vline
WA_PRU_4FSS_T3_V1_STR-T3101 sy-vline
WA_PRU_4FSS_T3_V1_STR-T3103 sy-vline
WA_PRU_4FSS_T3_V1_STR-T3104 sy-vline
WA_PRU_4FSS_T3_V1_STR-T3105 sy-vline
WA_PRU_4FSS_T3_V1_STR-T3111 sy-vline
WA_PRU_4FSS_T3_V1_STR-T3113 sy-vline
WA_PRU_4FSS_T3_V1_STR-T3114 sy-vline
WA_PRU_4FSS_T3_V1_STR-T3115 sy-vline
WA_PRU_4FSS_T3_V1_STR-T3123 sy-vline
WA_PRU_4FSS_T3_V1_STR-T3124 sy-vline
WA_PRU_4FSS_T3_V1_STR-T3133 sy-vline
WA_PRU_4FSS_T3_V1_STR-T3134 sy-vline
WA_PRU_4FSS_T3_V1_STR-T3135 sy-vline
WA_PRU_4FSS_T3_V1_STR-T3143 sy-vline
WA_PRU_4FSS_T3_V1_STR-T3144 sy-vline
WA_PRU_4FSS_T3_V1_STR-T3153 sy-vline
WA_PRU_4FSS_T3_V1_STR-T3154 sy-vline
WA_PRU_4FSS_T3_V1_STR-T3163 sy-vline
WA_PRU_4FSS_T3_V1_STR-T3164 sy-vline
WA_PRU_4FSS_T3_V1_STR-T3165 sy-vline
WA_PRU_4FSS_T3_V1_STR-T3YAR sy-vline
WA_PRU_4FSS_T3_V1_STR-T3174 sy-vline
WA_PRU_4FSS_T3_V1_STR-T3175 sy-vline
WA_PRU_4FSS_T3_V1_STR-T3181 sy-vline
WA_PRU_4FSS_T3_V1_STR-T3183 sy-vline
WA_PRU_4FSS_T3_V1_STR-T3184 sy-vline
WA_PRU_4FSS_T3_V1_STR-T3193 sy-vline
WA_PRU_4FSS_T3_V1_STR-T3194 sy-vline
WA_PRU_4FSS_T3_V1_STR-T3203 sy-vline
WA_PRU_4FSS_T3_V1_STR-T3204 sy-vline
WA_PRU_4FSS_T3_V1_STR-T3213 sy-vline
WA_PRU_4FSS_T3_V1_STR-T3214 sy-vline
WA_PRU_4FSS_T3_V1_STR-T3234 sy-vline
WA_PRU_4FSS_T3_V1_STR-T3244 sy-vline
WA_PRU_4FSS_T3_V1_STR-T3245 sy-vline
WA_PRU_4FSS_T3_V1_STR-T3SN1 sy-vline
WA_PRU_4FSS_T3_V1_STR-T3SN2 sy-vline
WA_PRU_4FSS_T3_V1_STR-T3SN3 sy-vline
WA_PRU_4FSS_T3_V1_STR-T3SN4 sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.