ABAP Select data from SAP table PRTHUKP into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP PRTHUKP table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to PRTHUKP. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the PRTHUKP table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_PRTHUKP TYPE STANDARD TABLE OF PRTHUKP,
      WA_PRTHUKP TYPE PRTHUKP,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: <PRTHUKP> TYPE PRTHUKP.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_PRTHUKP.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM PRTHUKP
  INTO TABLE IT_PRTHUKP.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM PRTHUKP
*  INTO TABLE @DATA(IT_PRTHUKP2).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_PRTHUKP INDEX 1 INTO DATA(WA_PRTHUKP2).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_PRTHUKP ASSIGNING <PRTHUKP>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
<PRTHUKP>-HUNUM = 1.
<PRTHUKP>-FACTOR = 1.
<PRTHUKP>-PACKNR = 1.
<PRTHUKP>-PINSTR_ID = 1.
<PRTHUKP>-PINSTR_TEXT = 1.
ENDLOOP.

LOOP AT IT_PRTHUKP INTO WA_PRTHUKP.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_PRTHUKP-PACKSTATU, sy-vline,
WA_PRTHUKP-PACKSTATU_LOCAL, sy-vline,
WA_PRTHUKP-ROOTHU, sy-vline,
WA_PRTHUKP-PACKLEVEL, sy-vline,
WA_PRTHUKP-CML_PACKGOOD, sy-vline,
WA_PRTHUKP-CMLQTY_A, sy-vline.
ENDLOOP. *Add any further fields from structure WA_PRTHUKP you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_PRTHUKP TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_PRTHUKP INTO WA_PRTHUKP. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.

*Conversion exit ALPHA, internal->external for field PINSTR_ID CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_PRTHUKP-PINSTR_ID IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_PRTHUKP-PINSTR_ID.
WRITE:/ 'New Value:', ld_input.

*Conversion exit MATN1, internal->external for field CML_PACKGOOD CALL FUNCTION 'CONVERSION_EXIT_MATN1_OUTPUT' EXPORTING input = WA_PRTHUKP-CML_PACKGOOD IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_PRTHUKP-CML_PACKGOOD.
WRITE:/ 'New Value:', ld_input.

*Conversion exit CUNIT, internal->external for field QUNIT_A CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_PRTHUKP-QUNIT_A IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_PRTHUKP-QUNIT_A.
WRITE:/ 'New Value:', ld_input.

*Conversion exit CUNIT, internal->external for field UNITDIM CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_PRTHUKP-UNITDIM IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_PRTHUKP-UNITDIM.
WRITE:/ 'New Value:', ld_input.

*Conversion exit CUNIT, internal->external for field UNITVOL_MAX CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_PRTHUKP-UNITVOL_MAX IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_PRTHUKP-UNITVOL_MAX.
WRITE:/ 'New Value:', ld_input.

*Conversion exit CUNIT, internal->external for field UNITVOL CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_PRTHUKP-UNITVOL IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_PRTHUKP-UNITVOL.
WRITE:/ 'New Value:', ld_input.

*Conversion exit CUNIT, internal->external for field UNITWEI_MAX CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_PRTHUKP-UNITWEI_MAX IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_PRTHUKP-UNITWEI_MAX.
WRITE:/ 'New Value:', ld_input.

*Conversion exit CUNIT, internal->external for field UNITWEI CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_PRTHUKP-UNITWEI IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_PRTHUKP-UNITWEI.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field EXIDV2 CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_PRTHUKP-EXIDV2 IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_PRTHUKP-EXIDV2.
WRITE:/ 'New Value:', ld_input.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_PRTHUKP_STR,
HUNUM TYPE STRING,
FACTOR TYPE STRING,
PACKNR TYPE STRING,
PINSTR_ID TYPE STRING,
PINSTR_TEXT TYPE STRING,
PACKSTATU TYPE STRING,
PACKSTATU_LOCAL TYPE STRING,
ROOTHU TYPE STRING,
PACKLEVEL TYPE STRING,
CML_PACKGOOD TYPE STRING,
CMLQTY_A TYPE STRING,
QUNIT_A TYPE STRING,
PACKGROUP TYPE STRING,
MANDT TYPE STRING,
HEIGHT TYPE STRING,
WIDTH TYPE STRING,
LENGTH TYPE STRING,
IHEIGHT TYPE STRING,
IWIDTH TYPE STRING,
ILENGTH TYPE STRING,
UNITDIM TYPE STRING,
SIZEFIX TYPE STRING,
TOTLVOL TYPE STRING,
LOADVOL TYPE STRING,
ALLOVOL TYPE STRING,
UNITVOL_MAX TYPE STRING,
TAREVOL TYPE STRING,
UNITVOL TYPE STRING,
TOLEVOL TYPE STRING,
INDCLOPA TYPE STRING,
VOLUMFIX TYPE STRING,
TOTLVOLCHGD TYPE STRING,
TOTLWEI TYPE STRING,
LOADWEI TYPE STRING,
ALLOWEI TYPE STRING,
UNITWEI_MAX TYPE STRING,
TAREWEI TYPE STRING,
UNITWEI TYPE STRING,
TOLEWEI TYPE STRING,
WEIGHTFIX TYPE STRING,
TOTLWEICHGD TYPE STRING,
MAXSTWE TYPE STRING,
STFAC TYPE STRING,
SHIPLABEL TYPE STRING,
VEGR1 TYPE STRING,
VEGR2 TYPE STRING,
VEGR3 TYPE STRING,
VEGR4 TYPE STRING,
VEGR5 TYPE STRING,
EXIDV2 TYPE STRING,
HU_TYPE TYPE STRING,END OF T_EKKO_STR. DATA: WA_PRTHUKP_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_PRTHUKP_STR-HUNUM sy-vline
WA_PRTHUKP_STR-FACTOR sy-vline
WA_PRTHUKP_STR-PACKNR sy-vline
WA_PRTHUKP_STR-PINSTR_ID sy-vline
WA_PRTHUKP_STR-PINSTR_TEXT sy-vline
WA_PRTHUKP_STR-PACKSTATU sy-vline
WA_PRTHUKP_STR-PACKSTATU_LOCAL sy-vline
WA_PRTHUKP_STR-ROOTHU sy-vline
WA_PRTHUKP_STR-PACKLEVEL sy-vline
WA_PRTHUKP_STR-CML_PACKGOOD sy-vline
WA_PRTHUKP_STR-CMLQTY_A sy-vline
WA_PRTHUKP_STR-QUNIT_A sy-vline
WA_PRTHUKP_STR-PACKGROUP sy-vline
WA_PRTHUKP_STR-MANDT sy-vline
WA_PRTHUKP_STR-HEIGHT sy-vline
WA_PRTHUKP_STR-WIDTH sy-vline
WA_PRTHUKP_STR-LENGTH sy-vline
WA_PRTHUKP_STR-IHEIGHT sy-vline
WA_PRTHUKP_STR-IWIDTH sy-vline
WA_PRTHUKP_STR-ILENGTH sy-vline
WA_PRTHUKP_STR-UNITDIM sy-vline
WA_PRTHUKP_STR-SIZEFIX sy-vline
WA_PRTHUKP_STR-TOTLVOL sy-vline
WA_PRTHUKP_STR-LOADVOL sy-vline
WA_PRTHUKP_STR-ALLOVOL sy-vline
WA_PRTHUKP_STR-UNITVOL_MAX sy-vline
WA_PRTHUKP_STR-TAREVOL sy-vline
WA_PRTHUKP_STR-UNITVOL sy-vline
WA_PRTHUKP_STR-TOLEVOL sy-vline
WA_PRTHUKP_STR-INDCLOPA sy-vline
WA_PRTHUKP_STR-VOLUMFIX sy-vline
WA_PRTHUKP_STR-TOTLVOLCHGD sy-vline
WA_PRTHUKP_STR-TOTLWEI sy-vline
WA_PRTHUKP_STR-LOADWEI sy-vline
WA_PRTHUKP_STR-ALLOWEI sy-vline
WA_PRTHUKP_STR-UNITWEI_MAX sy-vline
WA_PRTHUKP_STR-TAREWEI sy-vline
WA_PRTHUKP_STR-UNITWEI sy-vline
WA_PRTHUKP_STR-TOLEWEI sy-vline
WA_PRTHUKP_STR-WEIGHTFIX sy-vline
WA_PRTHUKP_STR-TOTLWEICHGD sy-vline
WA_PRTHUKP_STR-MAXSTWE sy-vline
WA_PRTHUKP_STR-STFAC sy-vline
WA_PRTHUKP_STR-SHIPLABEL sy-vline
WA_PRTHUKP_STR-VEGR1 sy-vline
WA_PRTHUKP_STR-VEGR2 sy-vline
WA_PRTHUKP_STR-VEGR3 sy-vline
WA_PRTHUKP_STR-VEGR4 sy-vline
WA_PRTHUKP_STR-VEGR5 sy-vline
WA_PRTHUKP_STR-EXIDV2 sy-vline
WA_PRTHUKP_STR-HU_TYPE sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.