ABAP Select data from SAP table PROJSTAT into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP PROJSTAT table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to PROJSTAT. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the PROJSTAT table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_PROJSTAT TYPE STANDARD TABLE OF PROJSTAT,
      WA_PROJSTAT TYPE PROJSTAT,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: <PROJSTAT> TYPE PROJSTAT.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_PROJSTAT.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM PROJSTAT
  INTO TABLE IT_PROJSTAT.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM PROJSTAT
*  INTO TABLE @DATA(IT_PROJSTAT2).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_PROJSTAT INDEX 1 INTO DATA(WA_PROJSTAT2).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_PROJSTAT ASSIGNING <PROJSTAT>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
<PROJSTAT>-PROJECT_ID = 1.
<PROJSTAT>-OBJ_TYPE = 1.
<PROJSTAT>-NODE_ID = 1.
<PROJSTAT>-NODE_TYPE = 1.
<PROJSTAT>-ID = 1.
ENDLOOP.

LOOP AT IT_PROJSTAT INTO WA_PROJSTAT.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_PROJSTAT-STATUS, sy-vline,
WA_PROJSTAT-PLANSTART, sy-vline,
WA_PROJSTAT-PLANEND, sy-vline,
WA_PROJSTAT-PLANDUR, sy-vline,
WA_PROJSTAT-ACTULSTART, sy-vline,
WA_PROJSTAT-ACTULEND, sy-vline.
ENDLOOP. *Add any further fields from structure WA_PROJSTAT you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_PROJSTAT TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_PROJSTAT INTO WA_PROJSTAT. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.

*Conversion exit ALPHA, internal->external for field PROJECT_ID CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_PROJSTAT-PROJECT_ID IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_PROJSTAT-PROJECT_ID.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ISOLA, internal->external for field PROJ_LANG CALL FUNCTION 'CONVERSION_EXIT_ISOLA_OUTPUT' EXPORTING input = WA_PROJSTAT-PROJ_LANG IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_PROJSTAT-PROJ_LANG.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field REF_PROJ CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_PROJSTAT-REF_PROJ IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_PROJSTAT-REF_PROJ.
WRITE:/ 'New Value:', ld_input.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_PROJSTAT_STR,
PROJECT_ID TYPE STRING,
OBJ_TYPE TYPE STRING,
NODE_ID TYPE STRING,
NODE_TYPE TYPE STRING,
ID TYPE STRING,
STATUS TYPE STRING,
PLANSTART TYPE STRING,
PLANEND TYPE STRING,
PLANDUR TYPE STRING,
ACTULSTART TYPE STRING,
ACTULEND TYPE STRING,
ACTULDUR TYPE STRING,
RESTWORK TYPE STRING,
DONE TYPE STRING,
PRIORITY TYPE STRING,
ISP_PLAN TYPE STRING,
ISP_ELEM TYPE STRING,
ISP_CODE TYPE STRING,
STAT_REL TYPE STRING,
ISP_CODE2 TYPE STRING,
ISP_CODE3 TYPE STRING,
FDATE TYPE STRING,
FUSER TYPE STRING,
LDATE TYPE STRING,
LUSER TYPE STRING,
FTIME TYPE STRING,
LTIME TYPE STRING,
CLASS TYPE STRING,
PROJ_LANG TYPE STRING,
RESPONSIBL TYPE STRING,
APP_COMP TYPE STRING,
REF_PROJ TYPE STRING,
BEGIN_DATE TYPE STRING,
END_DATE TYPE STRING,
RELEASE TYPE STRING,
KENN1 TYPE STRING,
PFDATE TYPE STRING,
PFUSER TYPE STRING,
PLDATE TYPE STRING,
PLUSER TYPE STRING,END OF T_EKKO_STR. DATA: WA_PROJSTAT_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_PROJSTAT_STR-PROJECT_ID sy-vline
WA_PROJSTAT_STR-OBJ_TYPE sy-vline
WA_PROJSTAT_STR-NODE_ID sy-vline
WA_PROJSTAT_STR-NODE_TYPE sy-vline
WA_PROJSTAT_STR-ID sy-vline
WA_PROJSTAT_STR-STATUS sy-vline
WA_PROJSTAT_STR-PLANSTART sy-vline
WA_PROJSTAT_STR-PLANEND sy-vline
WA_PROJSTAT_STR-PLANDUR sy-vline
WA_PROJSTAT_STR-ACTULSTART sy-vline
WA_PROJSTAT_STR-ACTULEND sy-vline
WA_PROJSTAT_STR-ACTULDUR sy-vline
WA_PROJSTAT_STR-RESTWORK sy-vline
WA_PROJSTAT_STR-DONE sy-vline
WA_PROJSTAT_STR-PRIORITY sy-vline
WA_PROJSTAT_STR-ISP_PLAN sy-vline
WA_PROJSTAT_STR-ISP_ELEM sy-vline
WA_PROJSTAT_STR-ISP_CODE sy-vline
WA_PROJSTAT_STR-STAT_REL sy-vline
WA_PROJSTAT_STR-ISP_CODE2 sy-vline
WA_PROJSTAT_STR-ISP_CODE3 sy-vline
WA_PROJSTAT_STR-FDATE sy-vline
WA_PROJSTAT_STR-FUSER sy-vline
WA_PROJSTAT_STR-LDATE sy-vline
WA_PROJSTAT_STR-LUSER sy-vline
WA_PROJSTAT_STR-FTIME sy-vline
WA_PROJSTAT_STR-LTIME sy-vline
WA_PROJSTAT_STR-CLASS sy-vline
WA_PROJSTAT_STR-PROJ_LANG sy-vline
WA_PROJSTAT_STR-RESPONSIBL sy-vline
WA_PROJSTAT_STR-APP_COMP sy-vline
WA_PROJSTAT_STR-REF_PROJ sy-vline
WA_PROJSTAT_STR-BEGIN_DATE sy-vline
WA_PROJSTAT_STR-END_DATE sy-vline
WA_PROJSTAT_STR-RELEASE sy-vline
WA_PROJSTAT_STR-KENN1 sy-vline
WA_PROJSTAT_STR-PFDATE sy-vline
WA_PROJSTAT_STR-PFUSER sy-vline
WA_PROJSTAT_STR-PLDATE sy-vline
WA_PROJSTAT_STR-PLUSER sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.