ABAP Select data from SAP table PROJS into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP PROJS table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to PROJS. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the PROJS table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_PROJS TYPE STANDARD TABLE OF PROJS,
      WA_PROJS TYPE PROJS,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: <PROJS> TYPE PROJS.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_PROJS.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM PROJS
  INTO TABLE IT_PROJS.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM PROJS
*  INTO TABLE @DATA(IT_PROJS2).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_PROJS INDEX 1 INTO DATA(WA_PROJS2).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_PROJS ASSIGNING <PROJS>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
<PROJS>-MANDT = 1.
<PROJS>-PSPNR = 1.
<PROJS>-PSPID = 1.
<PROJS>-POST1 = 1.
<PROJS>-OBJNR = 1.
ENDLOOP.

LOOP AT IT_PROJS INTO WA_PROJS.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_PROJS-ERNAM, sy-vline,
WA_PROJS-ERDAT, sy-vline,
WA_PROJS-AENAM, sy-vline,
WA_PROJS-AEDAT, sy-vline,
WA_PROJS-KIMSK, sy-vline,
WA_PROJS-AUTOD, sy-vline.
ENDLOOP. *Add any further fields from structure WA_PROJS you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_PROJS TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_PROJS INTO WA_PROJS. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.

*Conversion exit KONPS, internal->external for field PSPNR CALL FUNCTION 'CONVERSION_EXIT_KONPS_OUTPUT' EXPORTING input = WA_PROJS-PSPNR IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_PROJS-PSPNR.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ABPSN, internal->external for field PSPID CALL FUNCTION 'CONVERSION_EXIT_ABPSN_OUTPUT' EXPORTING input = WA_PROJS-PSPID IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_PROJS-PSPID.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field PRCTR CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_PROJS-PRCTR IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_PROJS-PRCTR.
WRITE:/ 'New Value:', ld_input.

*Conversion exit CUNIT, internal->external for field ZTEHT CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_PROJS-ZTEHT IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_PROJS-ZTEHT.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ISOLA, internal->external for field TXTSP CALL FUNCTION 'CONVERSION_EXIT_ISOLA_OUTPUT' EXPORTING input = WA_PROJS-TXTSP IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_PROJS-TXTSP.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field KOSTL CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_PROJS-KOSTL IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_PROJS-KOSTL.
WRITE:/ 'New Value:', ld_input.

*Conversion exit KONPS, internal->external for field SPSNR CALL FUNCTION 'CONVERSION_EXIT_KONPS_OUTPUT' EXPORTING input = WA_PROJS-SPSNR IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_PROJS-SPSNR.
WRITE:/ 'New Value:', ld_input.

*Conversion exit SCOPE, internal->external for field SCOPE CALL FUNCTION 'CONVERSION_EXIT_SCOPE_OUTPUT' EXPORTING input = WA_PROJS-SCOPE IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_PROJS-SCOPE.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field VNAME CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_PROJS-VNAME IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_PROJS-VNAME.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field RECID CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_PROJS-RECID IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_PROJS-RECID.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field ETYPE CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_PROJS-ETYPE IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_PROJS-ETYPE.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field OTYPE CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_PROJS-OTYPE IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_PROJS-OTYPE.
WRITE:/ 'New Value:', ld_input.

*Conversion exit CUNIT, internal->external for field USE04 CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_PROJS-USE04 IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_PROJS-USE04.
WRITE:/ 'New Value:', ld_input.

*Conversion exit CUNIT, internal->external for field USE05 CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_PROJS-USE05 IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_PROJS-USE05.
WRITE:/ 'New Value:', ld_input.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_PROJS_STR,
MANDT TYPE STRING,
PSPNR TYPE STRING,
PSPID TYPE STRING,
POST1 TYPE STRING,
OBJNR TYPE STRING,
ERNAM TYPE STRING,
ERDAT TYPE STRING,
AENAM TYPE STRING,
AEDAT TYPE STRING,
KIMSK TYPE STRING,
AUTOD TYPE STRING,
STSPD TYPE STRING,
STSPR TYPE STRING,
VERNR TYPE STRING,
VERNA TYPE STRING,
ASTNR TYPE STRING,
ASTNA TYPE STRING,
VBUKR TYPE STRING,
VGSBR TYPE STRING,
VKOKR TYPE STRING,
PRCTR TYPE STRING,
PWHIE TYPE STRING,
ZUORD TYPE STRING,
TRMEQ TYPE STRING,
PLFAZ TYPE STRING,
PLSEZ TYPE STRING,
WERKS TYPE STRING,
KALID TYPE STRING,
VGPLF TYPE STRING,
EWPLF TYPE STRING,
ZTEHT TYPE STRING,
NZANZ TYPE STRING,
PLNAW TYPE STRING,
VPROF TYPE STRING,
PROFL TYPE STRING,
BPROF TYPE STRING,
TXTSP TYPE STRING,
KOSTL TYPE STRING,
KTRG TYPE STRING,
AEDTE TYPE STRING,
AEDTP TYPE STRING,
BERST TYPE STRING,
BERTR TYPE STRING,
BERKO TYPE STRING,
BERBU TYPE STRING,
SPSNR TYPE STRING,
BESTA TYPE STRING,
SCOPE TYPE STRING,
XSTAT TYPE STRING,
TXJCD TYPE STRING,
ZSCHM TYPE STRING,
SCPRF TYPE STRING,
IMPRF TYPE STRING,
FMPRF TYPE STRING,
ABGSL TYPE STRING,
POSTU TYPE STRING,
PPROF TYPE STRING,
PLINT TYPE STRING,
LOEVM TYPE STRING,
INACT TYPE STRING,
KZBWS TYPE STRING,
SMPRF TYPE STRING,
FLGWBS TYPE STRING,
FLGVRG TYPE STRING,
GRTOP TYPE STRING,
PGPRF TYPE STRING,
STORT TYPE STRING,
FLGSD TYPE STRING,
KZERB TYPE STRING,
PARGR TYPE STRING,
FUNC_AREA TYPE STRING,
VKORG TYPE STRING,
VTWEG TYPE STRING,
SPART TYPE STRING,
DPPPROF TYPE STRING,
VPKSTU TYPE STRING,
SCHTYP TYPE STRING,
PSPID_EDIT TYPE STRING,
VNAME TYPE STRING,
RECID TYPE STRING,
ETYPE TYPE STRING,
OTYPE TYPE STRING,
JIBCL TYPE STRING,
JIBSA TYPE STRING,
SLWID TYPE STRING,
USR00 TYPE STRING,
USR01 TYPE STRING,
USR02 TYPE STRING,
USR03 TYPE STRING,
USR04 TYPE STRING,
USE04 TYPE STRING,
USR05 TYPE STRING,
USE05 TYPE STRING,
USR06 TYPE STRING,
USE06 TYPE STRING,
USR07 TYPE STRING,
USE07 TYPE STRING,
USR08 TYPE STRING,
USR09 TYPE STRING,
USR10 TYPE STRING,
USR11 TYPE STRING,END OF T_EKKO_STR. DATA: WA_PROJS_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_PROJS_STR-MANDT sy-vline
WA_PROJS_STR-PSPNR sy-vline
WA_PROJS_STR-PSPID sy-vline
WA_PROJS_STR-POST1 sy-vline
WA_PROJS_STR-OBJNR sy-vline
WA_PROJS_STR-ERNAM sy-vline
WA_PROJS_STR-ERDAT sy-vline
WA_PROJS_STR-AENAM sy-vline
WA_PROJS_STR-AEDAT sy-vline
WA_PROJS_STR-KIMSK sy-vline
WA_PROJS_STR-AUTOD sy-vline
WA_PROJS_STR-STSPD sy-vline
WA_PROJS_STR-STSPR sy-vline
WA_PROJS_STR-VERNR sy-vline
WA_PROJS_STR-VERNA sy-vline
WA_PROJS_STR-ASTNR sy-vline
WA_PROJS_STR-ASTNA sy-vline
WA_PROJS_STR-VBUKR sy-vline
WA_PROJS_STR-VGSBR sy-vline
WA_PROJS_STR-VKOKR sy-vline
WA_PROJS_STR-PRCTR sy-vline
WA_PROJS_STR-PWHIE sy-vline
WA_PROJS_STR-ZUORD sy-vline
WA_PROJS_STR-TRMEQ sy-vline
WA_PROJS_STR-PLFAZ sy-vline
WA_PROJS_STR-PLSEZ sy-vline
WA_PROJS_STR-WERKS sy-vline
WA_PROJS_STR-KALID sy-vline
WA_PROJS_STR-VGPLF sy-vline
WA_PROJS_STR-EWPLF sy-vline
WA_PROJS_STR-ZTEHT sy-vline
WA_PROJS_STR-NZANZ sy-vline
WA_PROJS_STR-PLNAW sy-vline
WA_PROJS_STR-VPROF sy-vline
WA_PROJS_STR-PROFL sy-vline
WA_PROJS_STR-BPROF sy-vline
WA_PROJS_STR-TXTSP sy-vline
WA_PROJS_STR-KOSTL sy-vline
WA_PROJS_STR-KTRG sy-vline
WA_PROJS_STR-AEDTE sy-vline
WA_PROJS_STR-AEDTP sy-vline
WA_PROJS_STR-BERST sy-vline
WA_PROJS_STR-BERTR sy-vline
WA_PROJS_STR-BERKO sy-vline
WA_PROJS_STR-BERBU sy-vline
WA_PROJS_STR-SPSNR sy-vline
WA_PROJS_STR-BESTA sy-vline
WA_PROJS_STR-SCOPE sy-vline
WA_PROJS_STR-XSTAT sy-vline
WA_PROJS_STR-TXJCD sy-vline
WA_PROJS_STR-ZSCHM sy-vline
WA_PROJS_STR-SCPRF sy-vline
WA_PROJS_STR-IMPRF sy-vline
WA_PROJS_STR-FMPRF sy-vline
WA_PROJS_STR-ABGSL sy-vline
WA_PROJS_STR-POSTU sy-vline
WA_PROJS_STR-PPROF sy-vline
WA_PROJS_STR-PLINT sy-vline
WA_PROJS_STR-LOEVM sy-vline
WA_PROJS_STR-INACT sy-vline
WA_PROJS_STR-KZBWS sy-vline
WA_PROJS_STR-SMPRF sy-vline
WA_PROJS_STR-FLGWBS sy-vline
WA_PROJS_STR-FLGVRG sy-vline
WA_PROJS_STR-GRTOP sy-vline
WA_PROJS_STR-PGPRF sy-vline
WA_PROJS_STR-STORT sy-vline
WA_PROJS_STR-FLGSD sy-vline
WA_PROJS_STR-KZERB sy-vline
WA_PROJS_STR-PARGR sy-vline
WA_PROJS_STR-FUNC_AREA sy-vline
WA_PROJS_STR-VKORG sy-vline
WA_PROJS_STR-VTWEG sy-vline
WA_PROJS_STR-SPART sy-vline
WA_PROJS_STR-DPPPROF sy-vline
WA_PROJS_STR-VPKSTU sy-vline
WA_PROJS_STR-SCHTYP sy-vline
WA_PROJS_STR-PSPID_EDIT sy-vline
WA_PROJS_STR-VNAME sy-vline
WA_PROJS_STR-RECID sy-vline
WA_PROJS_STR-ETYPE sy-vline
WA_PROJS_STR-OTYPE sy-vline
WA_PROJS_STR-JIBCL sy-vline
WA_PROJS_STR-JIBSA sy-vline
WA_PROJS_STR-SLWID sy-vline
WA_PROJS_STR-USR00 sy-vline
WA_PROJS_STR-USR01 sy-vline
WA_PROJS_STR-USR02 sy-vline
WA_PROJS_STR-USR03 sy-vline
WA_PROJS_STR-USR04 sy-vline
WA_PROJS_STR-USE04 sy-vline
WA_PROJS_STR-USR05 sy-vline
WA_PROJS_STR-USE05 sy-vline
WA_PROJS_STR-USR06 sy-vline
WA_PROJS_STR-USE06 sy-vline
WA_PROJS_STR-USR07 sy-vline
WA_PROJS_STR-USE07 sy-vline
WA_PROJS_STR-USR08 sy-vline
WA_PROJS_STR-USR09 sy-vline
WA_PROJS_STR-USR10 sy-vline
WA_PROJS_STR-USR11 sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.