ABAP Select data from SAP table PROJBILLGELMNTFLW_S into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP PROJBILLGELMNTFLW_S table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to PROJBILLGELMNTFLW_S. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the PROJBILLGELMNTFLW_S table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_PROJBILLGELMNTFLW_S TYPE STANDARD TABLE OF PROJBILLGELMNTFLW_S,
      WA_PROJBILLGELMNTFLW_S TYPE PROJBILLGELMNTFLW_S,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: <PROJBILLGELMNTFLW_S> TYPE PROJBILLGELMNTFLW_S.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_PROJBILLGELMNTFLW_S.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM PROJBILLGELMNTFLW_S
  INTO TABLE IT_PROJBILLGELMNTFLW_S.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM PROJBILLGELMNTFLW_S
*  INTO TABLE @DATA(IT_PROJBILLGELMNTFLW_S2).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_PROJBILLGELMNTFLW_S INDEX 1 INTO DATA(WA_PROJBILLGELMNTFLW_S2).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_PROJBILLGELMNTFLW_S ASSIGNING <PROJBILLGELMNTFLW_S>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
<PROJBILLGELMNTFLW_S>-BILLINGDOCUMENT = 1.
<PROJBILLGELMNTFLW_S>-BILLINGDOCUMENTITEM = 1.
<PROJBILLGELMNTFLW_S>-BILLINGDOCUMENTTYPE = 1.
<PROJBILLGELMNTFLW_S>-SDDOCUMENTCATEGORY = 1.
<PROJBILLGELMNTFLW_S>-PRECEDINGDOCUMENT = 1.
ENDLOOP.

LOOP AT IT_PROJBILLGELMNTFLW_S INTO WA_PROJBILLGELMNTFLW_S.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_PROJBILLGELMNTFLW_S-PRECEDINGDOCUMENTITEM, sy-vline,
WA_PROJBILLGELMNTFLW_S-PRECEDINGDOCUMENTTYPE, sy-vline,
WA_PROJBILLGELMNTFLW_S-BILLINGDATE, sy-vline,
WA_PROJBILLGELMNTFLW_S-DOCUMENTBILLINGSTATUS, sy-vline,
WA_PROJBILLGELMNTFLW_S-NETPRICEAMOUNTINDOCCRCY, sy-vline,
WA_PROJBILLGELMNTFLW_S-BILLINGREQUESTEDQUANTITY, sy-vline.
ENDLOOP. *Add any further fields from structure WA_PROJBILLGELMNTFLW_S you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_PROJBILLGELMNTFLW_S TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_PROJBILLGELMNTFLW_S INTO WA_PROJBILLGELMNTFLW_S. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.

*Conversion exit ALPHA, internal->external for field BILLINGDOCUMENT CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_PROJBILLGELMNTFLW_S-BILLINGDOCUMENT IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_PROJBILLGELMNTFLW_S-BILLINGDOCUMENT.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field PRECEDINGDOCUMENT CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_PROJBILLGELMNTFLW_S-PRECEDINGDOCUMENT IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_PROJBILLGELMNTFLW_S-PRECEDINGDOCUMENT.
WRITE:/ 'New Value:', ld_input.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_PROJBILLGELMNTFLW_S_STR,
BILLINGDOCUMENT TYPE STRING,
BILLINGDOCUMENTITEM TYPE STRING,
BILLINGDOCUMENTTYPE TYPE STRING,
SDDOCUMENTCATEGORY TYPE STRING,
PRECEDINGDOCUMENT TYPE STRING,
PRECEDINGDOCUMENTITEM TYPE STRING,
PRECEDINGDOCUMENTTYPE TYPE STRING,
BILLINGDATE TYPE STRING,
DOCUMENTBILLINGSTATUS TYPE STRING,
NETPRICEAMOUNTINDOCCRCY TYPE STRING,
BILLINGREQUESTEDQUANTITY TYPE STRING,
BILLGREQDAMTINTRANSACCRCY TYPE STRING,
BILLGREQDAMTINPROJECTCRCY TYPE STRING,
BILLGREQDAMTINGLOBALCRCY TYPE STRING,
WRITTENOFFQUANTITY TYPE STRING,
WRITTENOFFAMTINTRANSACCRCY TYPE STRING,
WRITTENOFFAMTINPROJECTCRCY TYPE STRING,
WRITTENOFFAMTINGLOBALCRCY TYPE STRING,
POSTPONEDQUANTITY TYPE STRING,
POSTPONEDAMOUNTINTRANSACCRCY TYPE STRING,
POSTPONEDAMOUNTINPROJECTCRCY TYPE STRING,
POSTPONEDAMOUNTINGLOBALCRCY TYPE STRING,
BILLGREQDREVENUEAMTINDOCCRCY TYPE STRING,
WRITTENOFFREVENUEAMTINDOCCRCY TYPE STRING,
PRJBLGELMENTRFLWCREATEDBYUSER TYPE STRING,
PRJBLGELMENTRFLWCRTEDATDTETME TYPE STRING,
PRJBLGELMENTRFLWCHANGEDBYUSER TYPE STRING,
PRJBLGELMENTRFLWCHGDATDTETME TYPE STRING,END OF T_EKKO_STR. DATA: WA_PROJBILLGELMNTFLW_S_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_PROJBILLGELMNTFLW_S_STR-BILLINGDOCUMENT sy-vline
WA_PROJBILLGELMNTFLW_S_STR-BILLINGDOCUMENTITEM sy-vline
WA_PROJBILLGELMNTFLW_S_STR-BILLINGDOCUMENTTYPE sy-vline
WA_PROJBILLGELMNTFLW_S_STR-SDDOCUMENTCATEGORY sy-vline
WA_PROJBILLGELMNTFLW_S_STR-PRECEDINGDOCUMENT sy-vline
WA_PROJBILLGELMNTFLW_S_STR-PRECEDINGDOCUMENTITEM sy-vline
WA_PROJBILLGELMNTFLW_S_STR-PRECEDINGDOCUMENTTYPE sy-vline
WA_PROJBILLGELMNTFLW_S_STR-BILLINGDATE sy-vline
WA_PROJBILLGELMNTFLW_S_STR-DOCUMENTBILLINGSTATUS sy-vline
WA_PROJBILLGELMNTFLW_S_STR-NETPRICEAMOUNTINDOCCRCY sy-vline
WA_PROJBILLGELMNTFLW_S_STR-BILLINGREQUESTEDQUANTITY sy-vline
WA_PROJBILLGELMNTFLW_S_STR-BILLGREQDAMTINTRANSACCRCY sy-vline
WA_PROJBILLGELMNTFLW_S_STR-BILLGREQDAMTINPROJECTCRCY sy-vline
WA_PROJBILLGELMNTFLW_S_STR-BILLGREQDAMTINGLOBALCRCY sy-vline
WA_PROJBILLGELMNTFLW_S_STR-WRITTENOFFQUANTITY sy-vline
WA_PROJBILLGELMNTFLW_S_STR-WRITTENOFFAMTINTRANSACCRCY sy-vline
WA_PROJBILLGELMNTFLW_S_STR-WRITTENOFFAMTINPROJECTCRCY sy-vline
WA_PROJBILLGELMNTFLW_S_STR-WRITTENOFFAMTINGLOBALCRCY sy-vline
WA_PROJBILLGELMNTFLW_S_STR-POSTPONEDQUANTITY sy-vline
WA_PROJBILLGELMNTFLW_S_STR-POSTPONEDAMOUNTINTRANSACCRCY sy-vline
WA_PROJBILLGELMNTFLW_S_STR-POSTPONEDAMOUNTINPROJECTCRCY sy-vline
WA_PROJBILLGELMNTFLW_S_STR-POSTPONEDAMOUNTINGLOBALCRCY sy-vline
WA_PROJBILLGELMNTFLW_S_STR-BILLGREQDREVENUEAMTINDOCCRCY sy-vline
WA_PROJBILLGELMNTFLW_S_STR-WRITTENOFFREVENUEAMTINDOCCRCY sy-vline
WA_PROJBILLGELMNTFLW_S_STR-PRJBLGELMENTRFLWCREATEDBYUSER sy-vline
WA_PROJBILLGELMNTFLW_S_STR-PRJBLGELMENTRFLWCRTEDATDTETME sy-vline
WA_PROJBILLGELMNTFLW_S_STR-PRJBLGELMENTRFLWCHANGEDBYUSER sy-vline
WA_PROJBILLGELMNTFLW_S_STR-PRJBLGELMENTRFLWCHGDATDTETME sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.