ABAP Select data from SAP table PREPFINDRT_07 into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP PREPFINDRT_07 table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to PREPFINDRT_07. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the PREPFINDRT_07 table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_PREPFINDRT_07 TYPE STANDARD TABLE OF PREPFINDRT_07,
      WA_PREPFINDRT_07 TYPE PREPFINDRT_07,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: <PREPFINDRT_07> TYPE PREPFINDRT_07.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_PREPFINDRT_07.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM PREPFINDRT_07
  INTO TABLE IT_PREPFINDRT_07.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM PREPFINDRT_07
*  INTO TABLE @DATA(IT_PREPFINDRT_072).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_PREPFINDRT_07 INDEX 1 INTO DATA(WA_PREPFINDRT_072).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_PREPFINDRT_07 ASSIGNING <PREPFINDRT_07>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
<PREPFINDRT_07>-MANDT = 1.
<PREPFINDRT_07>-RDIMEN = 1.
<PREPFINDRT_07>-RLDNR_FIN = 1.
<PREPFINDRT_07>-DOCLN_FIN = 1.
<PREPFINDRT_07>-RITCLG = 1.
ENDLOOP.

LOOP AT IT_PREPFINDRT_07 INTO WA_PREPFINDRT_07.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_PREPFINDRT_07-ROBUKRS, sy-vline,
WA_PREPFINDRT_07-RBUPTR, sy-vline,
WA_PREPFINDRT_07-RVERS, sy-vline,
WA_PREPFINDRT_07-RBUNIT, sy-vline,
WA_PREPFINDRT_07-BUDAT, sy-vline,
WA_PREPFINDRT_07-BELNR, sy-vline.
ENDLOOP. *Add any further fields from structure WA_PREPFINDRT_07 you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_PREPFINDRT_07 TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_PREPFINDRT_07 INTO WA_PREPFINDRT_07. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.

*Conversion exit ALPHA, internal->external for field RLDNR_FIN CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_PREPFINDRT_07-RLDNR_FIN IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_PREPFINDRT_07-RLDNR_FIN.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field RVERS CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_PREPFINDRT_07-RVERS IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_PREPFINDRT_07-RVERS.
WRITE:/ 'New Value:', ld_input.

*Conversion exit AFIMC, internal->external for field RBUNIT CALL FUNCTION 'CONVERSION_EXIT_AFIMC_OUTPUT' EXPORTING input = WA_PREPFINDRT_07-RBUNIT IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_PREPFINDRT_07-RBUNIT.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field BELNR CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_PREPFINDRT_07-BELNR IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_PREPFINDRT_07-BELNR.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field RLDNR CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_PREPFINDRT_07-RLDNR IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_PREPFINDRT_07-RLDNR.
WRITE:/ 'New Value:', ld_input.

*Conversion exit GJAHR, internal->external for field RYEAR CALL FUNCTION 'CONVERSION_EXIT_GJAHR_OUTPUT' EXPORTING input = WA_PREPFINDRT_07-RYEAR IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_PREPFINDRT_07-RYEAR.
WRITE:/ 'New Value:', ld_input.

*Conversion exit BFIMC, internal->external for field RITEM CALL FUNCTION 'CONVERSION_EXIT_BFIMC_OUTPUT' EXPORTING input = WA_PREPFINDRT_07-RITEM IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_PREPFINDRT_07-RITEM.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field RCNTR CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_PREPFINDRT_07-RCNTR IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_PREPFINDRT_07-RCNTR.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field RACCT CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_PREPFINDRT_07-RACCT IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_PREPFINDRT_07-RACCT.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field PRCTR CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_PREPFINDRT_07-PRCTR IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_PREPFINDRT_07-PRCTR.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field SEGMENT CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_PREPFINDRT_07-SEGMENT IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_PREPFINDRT_07-SEGMENT.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field REFDOCNR CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_PREPFINDRT_07-REFDOCNR IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_PREPFINDRT_07-REFDOCNR.
WRITE:/ 'New Value:', ld_input.

*Conversion exit GJAHR, internal->external for field REFRYEAR CALL FUNCTION 'CONVERSION_EXIT_GJAHR_OUTPUT' EXPORTING input = WA_PREPFINDRT_07-REFRYEAR IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_PREPFINDRT_07-REFRYEAR.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field LOGSYS CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_PREPFINDRT_07-LOGSYS IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_PREPFINDRT_07-LOGSYS.
WRITE:/ 'New Value:', ld_input.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_PREPFINDRT_07_STR,
MANDT TYPE STRING,
RDIMEN TYPE STRING,
RLDNR_FIN TYPE STRING,
DOCLN_FIN TYPE STRING,
RITCLG TYPE STRING,
ROBUKRS TYPE STRING,
RBUPTR TYPE STRING,
RVERS TYPE STRING,
RBUNIT TYPE STRING,
BUDAT TYPE STRING,
BELNR TYPE STRING,
DOCLN TYPE STRING,
RLDNR TYPE STRING,
RUNIT TYPE STRING,
POPER TYPE STRING,
FISCAL_YEAR_PERIOD TYPE STRING,
RYEAR TYPE STRING,
RITEM TYPE STRING,
SITYP TYPE STRING,
SUBIT TYPE STRING,
RMVCT TYPE STRING,
RFAREA TYPE STRING,
RBUSA TYPE STRING,
RCNTR TYPE STRING,
RACCT TYPE STRING,
PRCTR TYPE STRING,
SEGMENT TYPE STRING,
DOCTY TYPE STRING,
TSL TYPE STRING,
RTCUR TYPE STRING,
HSL TYPE STRING,
KSL TYPE STRING,
MSL TYPE STRING,
RLCURR TYPE STRING,
RGCURR TYPE STRING,
ACTIV TYPE STRING,
REFDOCNR TYPE STRING,
REFRYEAR TYPE STRING,
REFACTIV TYPE STRING,
USNAM TYPE STRING,
AWTYP TYPE STRING,
AWORG TYPE STRING,
LOGSYS TYPE STRING,END OF T_EKKO_STR. DATA: WA_PREPFINDRT_07_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_PREPFINDRT_07_STR-MANDT sy-vline
WA_PREPFINDRT_07_STR-RDIMEN sy-vline
WA_PREPFINDRT_07_STR-RLDNR_FIN sy-vline
WA_PREPFINDRT_07_STR-DOCLN_FIN sy-vline
WA_PREPFINDRT_07_STR-RITCLG sy-vline
WA_PREPFINDRT_07_STR-ROBUKRS sy-vline
WA_PREPFINDRT_07_STR-RBUPTR sy-vline
WA_PREPFINDRT_07_STR-RVERS sy-vline
WA_PREPFINDRT_07_STR-RBUNIT sy-vline
WA_PREPFINDRT_07_STR-BUDAT sy-vline
WA_PREPFINDRT_07_STR-BELNR sy-vline
WA_PREPFINDRT_07_STR-DOCLN sy-vline
WA_PREPFINDRT_07_STR-RLDNR sy-vline
WA_PREPFINDRT_07_STR-RUNIT sy-vline
WA_PREPFINDRT_07_STR-POPER sy-vline
WA_PREPFINDRT_07_STR-FISCAL_YEAR_PERIOD sy-vline
WA_PREPFINDRT_07_STR-RYEAR sy-vline
WA_PREPFINDRT_07_STR-RITEM sy-vline
WA_PREPFINDRT_07_STR-SITYP sy-vline
WA_PREPFINDRT_07_STR-SUBIT sy-vline
WA_PREPFINDRT_07_STR-RMVCT sy-vline
WA_PREPFINDRT_07_STR-RFAREA sy-vline
WA_PREPFINDRT_07_STR-RBUSA sy-vline
WA_PREPFINDRT_07_STR-RCNTR sy-vline
WA_PREPFINDRT_07_STR-RACCT sy-vline
WA_PREPFINDRT_07_STR-PRCTR sy-vline
WA_PREPFINDRT_07_STR-SEGMENT sy-vline
WA_PREPFINDRT_07_STR-DOCTY sy-vline
WA_PREPFINDRT_07_STR-TSL sy-vline
WA_PREPFINDRT_07_STR-RTCUR sy-vline
WA_PREPFINDRT_07_STR-HSL sy-vline
WA_PREPFINDRT_07_STR-KSL sy-vline
WA_PREPFINDRT_07_STR-MSL sy-vline
WA_PREPFINDRT_07_STR-RLCURR sy-vline
WA_PREPFINDRT_07_STR-RGCURR sy-vline
WA_PREPFINDRT_07_STR-ACTIV sy-vline
WA_PREPFINDRT_07_STR-REFDOCNR sy-vline
WA_PREPFINDRT_07_STR-REFRYEAR sy-vline
WA_PREPFINDRT_07_STR-REFACTIV sy-vline
WA_PREPFINDRT_07_STR-USNAM sy-vline
WA_PREPFINDRT_07_STR-AWTYP sy-vline
WA_PREPFINDRT_07_STR-AWORG sy-vline
WA_PREPFINDRT_07_STR-LOGSYS sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.