ABAP Select data from SAP table PRCTR_S_HIENODE_0106 into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP PRCTR_S_HIENODE_0106 table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to PRCTR_S_HIENODE_0106. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the PRCTR_S_HIENODE_0106 table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_PRCTR_S_HIENODE_0106 TYPE STANDARD TABLE OF PRCTR_S_HIENODE_0106,
      WA_PRCTR_S_HIENODE_0106 TYPE PRCTR_S_HIENODE_0106,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: <PRCTR_S_HIENODE_0106> TYPE PRCTR_S_HIENODE_0106.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_PRCTR_S_HIENODE_0106.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM PRCTR_S_HIENODE_0106
  INTO TABLE IT_PRCTR_S_HIENODE_0106.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM PRCTR_S_HIENODE_0106
*  INTO TABLE @DATA(IT_PRCTR_S_HIENODE_01062).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_PRCTR_S_HIENODE_0106 INDEX 1 INTO DATA(WA_PRCTR_S_HIENODE_01062).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_PRCTR_S_HIENODE_0106 ASSIGNING <PRCTR_S_HIENODE_0106>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
<PRCTR_S_HIENODE_0106>-NODEID = 1.
<PRCTR_S_HIENODE_0106>-IOBJNM = 1.
<PRCTR_S_HIENODE_0106>-NODENAME = 1.
<PRCTR_S_HIENODE_0106>-TLEVEL = 1.
<PRCTR_S_HIENODE_0106>-LINK = 1.
ENDLOOP.

LOOP AT IT_PRCTR_S_HIENODE_0106 INTO WA_PRCTR_S_HIENODE_0106.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_PRCTR_S_HIENODE_0106-PARENTID, sy-vline,
WA_PRCTR_S_HIENODE_0106-CHILDID, sy-vline,
WA_PRCTR_S_HIENODE_0106-NEXTID, sy-vline,
WA_PRCTR_S_HIENODE_0106-DATEFROM, sy-vline,
WA_PRCTR_S_HIENODE_0106-DATETO, sy-vline,
WA_PRCTR_S_HIENODE_0106-INTERVL, sy-vline.
ENDLOOP. *Add any further fields from structure WA_PRCTR_S_HIENODE_0106 you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_PRCTR_S_HIENODE_0106 TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_PRCTR_S_HIENODE_0106 INTO WA_PRCTR_S_HIENODE_0106. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.

*Conversion exit ALPHA, internal->external for field NODENAME CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_PRCTR_S_HIENODE_0106-NODENAME IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_PRCTR_S_HIENODE_0106-NODENAME.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field PRCTR CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_PRCTR_S_HIENODE_0106-PRCTR IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_PRCTR_S_HIENODE_0106-PRCTR.
WRITE:/ 'New Value:', ld_input.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_PRCTR_S_HIENODE_0106_STR,
NODEID TYPE STRING,
IOBJNM TYPE STRING,
NODENAME TYPE STRING,
TLEVEL TYPE STRING,
LINK TYPE STRING,
PARENTID TYPE STRING,
CHILDID TYPE STRING,
NEXTID TYPE STRING,
DATEFROM TYPE STRING,
DATETO TYPE STRING,
INTERVL TYPE STRING,
FIELDNM TYPE STRING,
KOKRS TYPE STRING,
PRCTR TYPE STRING,END OF T_EKKO_STR. DATA: WA_PRCTR_S_HIENODE_0106_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_PRCTR_S_HIENODE_0106_STR-NODEID sy-vline
WA_PRCTR_S_HIENODE_0106_STR-IOBJNM sy-vline
WA_PRCTR_S_HIENODE_0106_STR-NODENAME sy-vline
WA_PRCTR_S_HIENODE_0106_STR-TLEVEL sy-vline
WA_PRCTR_S_HIENODE_0106_STR-LINK sy-vline
WA_PRCTR_S_HIENODE_0106_STR-PARENTID sy-vline
WA_PRCTR_S_HIENODE_0106_STR-CHILDID sy-vline
WA_PRCTR_S_HIENODE_0106_STR-NEXTID sy-vline
WA_PRCTR_S_HIENODE_0106_STR-DATEFROM sy-vline
WA_PRCTR_S_HIENODE_0106_STR-DATETO sy-vline
WA_PRCTR_S_HIENODE_0106_STR-INTERVL sy-vline
WA_PRCTR_S_HIENODE_0106_STR-FIELDNM sy-vline
WA_PRCTR_S_HIENODE_0106_STR-KOKRS sy-vline
WA_PRCTR_S_HIENODE_0106_STR-PRCTR sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.