ABAP Select data from SAP table PPVCAVOLSECDRY into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP PPVCAVOLSECDRY table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to PPVCAVOLSECDRY. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the PPVCAVOLSECDRY table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_PPVCAVOLSECDRY TYPE STANDARD TABLE OF PPVCAVOLSECDRY,
      WA_PPVCAVOLSECDRY TYPE PPVCAVOLSECDRY,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: <PPVCAVOLSECDRY> TYPE PPVCAVOLSECDRY.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_PPVCAVOLSECDRY.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM PPVCAVOLSECDRY
  INTO TABLE IT_PPVCAVOLSECDRY.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM PPVCAVOLSECDRY
*  INTO TABLE @DATA(IT_PPVCAVOLSECDRY2).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_PPVCAVOLSECDRY INDEX 1 INTO DATA(WA_PPVCAVOLSECDRY2).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_PPVCAVOLSECDRY ASSIGNING <PPVCAVOLSECDRY>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
<PPVCAVOLSECDRY>-MANDT = 1.
<PPVCAVOLSECDRY>-MATERIAL = 1.
<PPVCAVOLSECDRY>-PRACONTRACT = 1.
<PPVCAVOLSECDRY>-DELIVERYNETWORK = 1.
<PPVCAVOLSECDRY>-MEASUREMENTPOINT = 1.
ENDLOOP.

LOOP AT IT_PPVCAVOLSECDRY INTO WA_PPVCAVOLSECDRY.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_PPVCAVOLSECDRY-WELL, sy-vline,
WA_PPVCAVOLSECDRY-WELLCOMPLETION, sy-vline,
WA_PPVCAVOLSECDRY-OWNERINTERESTTYPE, sy-vline,
WA_PPVCAVOLSECDRY-PRAOWNER, sy-vline,
WA_PPVCAVOLSECDRY-ORIGINATINGMEASUREMENTPT, sy-vline,
WA_PPVCAVOLSECDRY-OWNERINTERESTSEQUENCE, sy-vline.
ENDLOOP. *Add any further fields from structure WA_PPVCAVOLSECDRY you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_PPVCAVOLSECDRY TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_PPVCAVOLSECDRY INTO WA_PPVCAVOLSECDRY. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.

*Conversion exit MATN1, internal->external for field MATERIAL CALL FUNCTION 'CONVERSION_EXIT_MATN1_OUTPUT' EXPORTING input = WA_PPVCAVOLSECDRY-MATERIAL IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_PPVCAVOLSECDRY-MATERIAL.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field PRACONTRACT CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_PPVCAVOLSECDRY-PRACONTRACT IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_PPVCAVOLSECDRY-PRACONTRACT.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field DELIVERYNETWORK CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_PPVCAVOLSECDRY-DELIVERYNETWORK IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_PPVCAVOLSECDRY-DELIVERYNETWORK.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field MEASUREMENTPOINT CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_PPVCAVOLSECDRY-MEASUREMENTPOINT IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_PPVCAVOLSECDRY-MEASUREMENTPOINT.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field WELL CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_PPVCAVOLSECDRY-WELL IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_PPVCAVOLSECDRY-WELL.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field WELLCOMPLETION CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_PPVCAVOLSECDRY-WELLCOMPLETION IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_PPVCAVOLSECDRY-WELLCOMPLETION.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field PRAOWNER CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_PPVCAVOLSECDRY-PRAOWNER IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_PPVCAVOLSECDRY-PRAOWNER.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field ORIGINATINGMEASUREMENTPT CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_PPVCAVOLSECDRY-ORIGINATINGMEASUREMENTPT IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_PPVCAVOLSECDRY-ORIGINATINGMEASUREMENTPT.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field OWNERINTERESTSEQUENCE CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_PPVCAVOLSECDRY-OWNERINTERESTSEQUENCE IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_PPVCAVOLSECDRY-OWNERINTERESTSEQUENCE.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field TRANSPORTER CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_PPVCAVOLSECDRY-TRANSPORTER IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_PPVCAVOLSECDRY-TRANSPORTER.
WRITE:/ 'New Value:', ld_input.

*Conversion exit CUNIT, internal->external for field VOLUMEUNIT CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_PPVCAVOLSECDRY-VOLUMEUNIT IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_PPVCAVOLSECDRY-VOLUMEUNIT.
WRITE:/ 'New Value:', ld_input.

*Conversion exit CUNIT, internal->external for field HEATINGVALUNIT CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_PPVCAVOLSECDRY-HEATINGVALUNIT IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_PPVCAVOLSECDRY-HEATINGVALUNIT.
WRITE:/ 'New Value:', ld_input.

*Conversion exit CUNIT, internal->external for field ENERGYUNIT CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_PPVCAVOLSECDRY-ENERGYUNIT IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_PPVCAVOLSECDRY-ENERGYUNIT.
WRITE:/ 'New Value:', ld_input.

*Conversion exit CUNIT, internal->external for field VOLREDUCNUNIT CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_PPVCAVOLSECDRY-VOLREDUCNUNIT IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_PPVCAVOLSECDRY-VOLREDUCNUNIT.
WRITE:/ 'New Value:', ld_input.

*Conversion exit CUNIT, internal->external for field ENERGYREDUCNUNIT CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_PPVCAVOLSECDRY-ENERGYREDUCNUNIT IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_PPVCAVOLSECDRY-ENERGYREDUCNUNIT.
WRITE:/ 'New Value:', ld_input.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_PPVCAVOLSECDRY_STR,
MANDT TYPE STRING,
MATERIAL TYPE STRING,
PRACONTRACT TYPE STRING,
DELIVERYNETWORK TYPE STRING,
MEASUREMENTPOINT TYPE STRING,
WELL TYPE STRING,
WELLCOMPLETION TYPE STRING,
OWNERINTERESTTYPE TYPE STRING,
PRAOWNER TYPE STRING,
ORIGINATINGMEASUREMENTPT TYPE STRING,
OWNERINTERESTSEQUENCE TYPE STRING,
SALESDATE TYPE STRING,
TRANSPORTER TYPE STRING,
ISLEASEORPLANT TYPE STRING,
VOLUMEUNIT TYPE STRING,
HEATINGVALUNIT TYPE STRING,
ENERGYUNIT TYPE STRING,
VOLREDUCNUNIT TYPE STRING,
ENERGYREDUCNUNIT TYPE STRING,
ACTUALVOLUME TYPE STRING,
HEATINGVALUE TYPE STRING,
ACTUALENERGY TYPE STRING,
ENTITLEDVOLUME TYPE STRING,
ENTITLEDENERGY TYPE STRING,
ACTUALVOLREDUCN TYPE STRING,
ACTUALENERGYREDUCN TYPE STRING,
ENTITLEDVOLREDUCN TYPE STRING,
ENTITLEDENGYREDUCN TYPE STRING,
ORIGINTRANSACTION TYPE STRING,
CREATEDBYUSER TYPE STRING,
CREATIONDATETIME TYPE STRING,END OF T_EKKO_STR. DATA: WA_PPVCAVOLSECDRY_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_PPVCAVOLSECDRY_STR-MANDT sy-vline
WA_PPVCAVOLSECDRY_STR-MATERIAL sy-vline
WA_PPVCAVOLSECDRY_STR-PRACONTRACT sy-vline
WA_PPVCAVOLSECDRY_STR-DELIVERYNETWORK sy-vline
WA_PPVCAVOLSECDRY_STR-MEASUREMENTPOINT sy-vline
WA_PPVCAVOLSECDRY_STR-WELL sy-vline
WA_PPVCAVOLSECDRY_STR-WELLCOMPLETION sy-vline
WA_PPVCAVOLSECDRY_STR-OWNERINTERESTTYPE sy-vline
WA_PPVCAVOLSECDRY_STR-PRAOWNER sy-vline
WA_PPVCAVOLSECDRY_STR-ORIGINATINGMEASUREMENTPT sy-vline
WA_PPVCAVOLSECDRY_STR-OWNERINTERESTSEQUENCE sy-vline
WA_PPVCAVOLSECDRY_STR-SALESDATE sy-vline
WA_PPVCAVOLSECDRY_STR-TRANSPORTER sy-vline
WA_PPVCAVOLSECDRY_STR-ISLEASEORPLANT sy-vline
WA_PPVCAVOLSECDRY_STR-VOLUMEUNIT sy-vline
WA_PPVCAVOLSECDRY_STR-HEATINGVALUNIT sy-vline
WA_PPVCAVOLSECDRY_STR-ENERGYUNIT sy-vline
WA_PPVCAVOLSECDRY_STR-VOLREDUCNUNIT sy-vline
WA_PPVCAVOLSECDRY_STR-ENERGYREDUCNUNIT sy-vline
WA_PPVCAVOLSECDRY_STR-ACTUALVOLUME sy-vline
WA_PPVCAVOLSECDRY_STR-HEATINGVALUE sy-vline
WA_PPVCAVOLSECDRY_STR-ACTUALENERGY sy-vline
WA_PPVCAVOLSECDRY_STR-ENTITLEDVOLUME sy-vline
WA_PPVCAVOLSECDRY_STR-ENTITLEDENERGY sy-vline
WA_PPVCAVOLSECDRY_STR-ACTUALVOLREDUCN sy-vline
WA_PPVCAVOLSECDRY_STR-ACTUALENERGYREDUCN sy-vline
WA_PPVCAVOLSECDRY_STR-ENTITLEDVOLREDUCN sy-vline
WA_PPVCAVOLSECDRY_STR-ENTITLEDENGYREDUCN sy-vline
WA_PPVCAVOLSECDRY_STR-ORIGINTRANSACTION sy-vline
WA_PPVCAVOLSECDRY_STR-CREATEDBYUSER sy-vline
WA_PPVCAVOLSECDRY_STR-CREATIONDATETIME sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.