ABAP Select data from SAP table PPINT_BILL_OF_OPERATIONS_HEADE into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP PPINT_BILL_OF_OPERATIONS_HEADE table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to PPINT_BILL_OF_OPERATIONS_HEADE. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the PPINT_BILL_OF_OPERATIONS_HEADE table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_PPINT_BILL_OF_OPERATIONS_HEADE TYPE STANDARD TABLE OF PPINT_BILL_OF_OPERATIONS_HEADE,
      WA_PPINT_BILL_OF_OPERATIONS_HEADE TYPE PPINT_BILL_OF_OPERATIONS_HEADE,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: <PPINT_BILL_OF_OPERATIONS_HEADE> TYPE PPINT_BILL_OF_OPERATIONS_HEADE.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_PPINT_BILL_OF_OPERATIONS_HEADE.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM PPINT_BILL_OF_OPERATIONS_HEADE
  INTO TABLE IT_PPINT_BILL_OF_OPERATIONS_HEADE.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM PPINT_BILL_OF_OPERATIONS_HEADE
*  INTO TABLE @DATA(IT_PPINT_BILL_OF_OPERATIONS_HEADE2).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_PPINT_BILL_OF_OPERATIONS_HEADE INDEX 1 INTO DATA(WA_PPINT_BILL_OF_OPERATIONS_HEADE2).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_PPINT_BILL_OF_OPERATIONS_HEADE ASSIGNING <PPINT_BILL_OF_OPERATIONS_HEADE>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
<PPINT_BILL_OF_OPERATIONS_HEADE>-CONTROLLER = 1.
<PPINT_BILL_OF_OPERATIONS_HEADE>-BILL_OF_OPERATIONS_DESC = 1.
<PPINT_BILL_OF_OPERATIONS_HEADE>-BILL_OF_OPERATIONS_STATUS = 1.
<PPINT_BILL_OF_OPERATIONS_HEADE>-BILL_OF_OPERATIONS_PLANT = 1.
<PPINT_BILL_OF_OPERATIONS_HEADE>-BILL_OF_OPERATIONS_USAGE = 1.
ENDLOOP.

LOOP AT IT_PPINT_BILL_OF_OPERATIONS_HEADE INTO WA_PPINT_BILL_OF_OPERATIONS_HEADE.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_PPINT_BILL_OF_OPERATIONS_HEADE-BOOMIN_LOT_SIZE_QUANTITY, sy-vline,
WA_PPINT_BILL_OF_OPERATIONS_HEADE-CONTROLLER, sy-vline,
WA_PPINT_BILL_OF_OPERATIONS_HEADE-UNIT_CODE, sy-vline,
WA_PPINT_BILL_OF_OPERATIONS_HEADE-CONTENT, sy-vline,
WA_PPINT_BILL_OF_OPERATIONS_HEADE-BOOMAX_LOT_SIZE_QUANTITY, sy-vline,
WA_PPINT_BILL_OF_OPERATIONS_HEADE-CONTROLLER, sy-vline.
ENDLOOP. *Add any further fields from structure WA_PPINT_BILL_OF_OPERATIONS_HEADE you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_PPINT_BILL_OF_OPERATIONS_HEADE TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_PPINT_BILL_OF_OPERATIONS_HEADE INTO WA_PPINT_BILL_OF_OPERATIONS_HEADE. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_PPINT_BILL_OF_OPERATIONS_HEADE_STR,
CONTROLLER TYPE STRING,
BILL_OF_OPERATIONS_DESC TYPE STRING,
BILL_OF_OPERATIONS_STATUS TYPE STRING,
BILL_OF_OPERATIONS_PLANT TYPE STRING,
BILL_OF_OPERATIONS_USAGE TYPE STRING,
BOOMIN_LOT_SIZE_QUANTITY TYPE STRING,
CONTROLLER TYPE STRING,
UNIT_CODE TYPE STRING,
CONTENT TYPE STRING,
BOOMAX_LOT_SIZE_QUANTITY TYPE STRING,
CONTROLLER TYPE STRING,
UNIT_CODE TYPE STRING,
CONTENT TYPE STRING,
CHANGE_NUMBER TYPE STRING,
VALIDITY_START_DATE TYPE STRING,
VALIDITY_END_DATE TYPE STRING,
LONG_TEXT TYPE STRING,
CONTROLLER TYPE STRING,
LANGUAGE_CODE TYPE STRING,
MIMECODE TYPE STRING,
TEXT_CATEGORY TYPE STRING,
CONTENT TYPE STRING,
ACTION_CODE TYPE STRING,END OF T_EKKO_STR. DATA: WA_PPINT_BILL_OF_OPERATIONS_HEADE_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_PPINT_BILL_OF_OPERATIONS_HEADE_STR-CONTROLLER sy-vline
WA_PPINT_BILL_OF_OPERATIONS_HEADE_STR-BILL_OF_OPERATIONS_DESC sy-vline
WA_PPINT_BILL_OF_OPERATIONS_HEADE_STR-BILL_OF_OPERATIONS_STATUS sy-vline
WA_PPINT_BILL_OF_OPERATIONS_HEADE_STR-BILL_OF_OPERATIONS_PLANT sy-vline
WA_PPINT_BILL_OF_OPERATIONS_HEADE_STR-BILL_OF_OPERATIONS_USAGE sy-vline
WA_PPINT_BILL_OF_OPERATIONS_HEADE_STR-BOOMIN_LOT_SIZE_QUANTITY sy-vline
WA_PPINT_BILL_OF_OPERATIONS_HEADE_STR-CONTROLLER sy-vline
WA_PPINT_BILL_OF_OPERATIONS_HEADE_STR-UNIT_CODE sy-vline
WA_PPINT_BILL_OF_OPERATIONS_HEADE_STR-CONTENT sy-vline
WA_PPINT_BILL_OF_OPERATIONS_HEADE_STR-BOOMAX_LOT_SIZE_QUANTITY sy-vline
WA_PPINT_BILL_OF_OPERATIONS_HEADE_STR-CONTROLLER sy-vline
WA_PPINT_BILL_OF_OPERATIONS_HEADE_STR-UNIT_CODE sy-vline
WA_PPINT_BILL_OF_OPERATIONS_HEADE_STR-CONTENT sy-vline
WA_PPINT_BILL_OF_OPERATIONS_HEADE_STR-CHANGE_NUMBER sy-vline
WA_PPINT_BILL_OF_OPERATIONS_HEADE_STR-VALIDITY_START_DATE sy-vline
WA_PPINT_BILL_OF_OPERATIONS_HEADE_STR-VALIDITY_END_DATE sy-vline
WA_PPINT_BILL_OF_OPERATIONS_HEADE_STR-LONG_TEXT sy-vline
WA_PPINT_BILL_OF_OPERATIONS_HEADE_STR-CONTROLLER sy-vline
WA_PPINT_BILL_OF_OPERATIONS_HEADE_STR-LANGUAGE_CODE sy-vline
WA_PPINT_BILL_OF_OPERATIONS_HEADE_STR-MIMECODE sy-vline
WA_PPINT_BILL_OF_OPERATIONS_HEADE_STR-TEXT_CATEGORY sy-vline
WA_PPINT_BILL_OF_OPERATIONS_HEADE_STR-CONTENT sy-vline
WA_PPINT_BILL_OF_OPERATIONS_HEADE_STR-ACTION_CODE sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.