ABAP Select data from SAP table PPH_MDPS_EXT_TWO into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP PPH_MDPS_EXT_TWO table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to PPH_MDPS_EXT_TWO. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the PPH_MDPS_EXT_TWO table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_PPH_MDPS_EXT_TWO TYPE STANDARD TABLE OF PPH_MDPS_EXT_TWO,
      WA_PPH_MDPS_EXT_TWO TYPE PPH_MDPS_EXT_TWO,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: <PPH_MDPS_EXT_TWO> TYPE PPH_MDPS_EXT_TWO.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_PPH_MDPS_EXT_TWO.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM PPH_MDPS_EXT_TWO
  INTO TABLE IT_PPH_MDPS_EXT_TWO.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM PPH_MDPS_EXT_TWO
*  INTO TABLE @DATA(IT_PPH_MDPS_EXT_TWO2).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_PPH_MDPS_EXT_TWO INDEX 1 INTO DATA(WA_PPH_MDPS_EXT_TWO2).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_PPH_MDPS_EXT_TWO ASSIGNING <PPH_MDPS_EXT_TWO>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
<PPH_MDPS_EXT_TWO>-MANDT = 1.
<PPH_MDPS_EXT_TWO>-MATNR = 1.
<PPH_MDPS_EXT_TWO>-WERKS = 1.
<PPH_MDPS_EXT_TWO>-BERID = 1.
<PPH_MDPS_EXT_TWO>-DAT00 = 1.
ENDLOOP.

LOOP AT IT_PPH_MDPS_EXT_TWO INTO WA_PPH_MDPS_EXT_TWO.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_PPH_MDPS_EXT_TWO-SORT1, sy-vline,
WA_PPH_MDPS_EXT_TWO-SORT2, sy-vline,
WA_PPH_MDPS_EXT_TWO-DELKZ, sy-vline,
WA_PPH_MDPS_EXT_TWO-VRFKZ, sy-vline,
WA_PPH_MDPS_EXT_TWO-PLUMI, sy-vline,
WA_PPH_MDPS_EXT_TWO-MNG01, sy-vline.
ENDLOOP. *Add any further fields from structure WA_PPH_MDPS_EXT_TWO you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_PPH_MDPS_EXT_TWO TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_PPH_MDPS_EXT_TWO INTO WA_PPH_MDPS_EXT_TWO. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.

*Conversion exit MATN1, internal->external for field MATNR CALL FUNCTION 'CONVERSION_EXIT_MATN1_OUTPUT' EXPORTING input = WA_PPH_MDPS_EXT_TWO-MATNR IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_PPH_MDPS_EXT_TWO-MATNR.
WRITE:/ 'New Value:', ld_input.

*Conversion exit NUMCV, internal->external for field REVLV CALL FUNCTION 'CONVERSION_EXIT_NUMCV_OUTPUT' EXPORTING input = WA_PPH_MDPS_EXT_TWO-REVLV IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_PPH_MDPS_EXT_TWO-REVLV.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field STALT CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_PPH_MDPS_EXT_TWO-STALT IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_PPH_MDPS_EXT_TWO-STALT.
WRITE:/ 'New Value:', ld_input.

*Conversion exit MATN1, internal->external for field NFMAT CALL FUNCTION 'CONVERSION_EXIT_MATN1_OUTPUT' EXPORTING input = WA_PPH_MDPS_EXT_TWO-NFMAT IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_PPH_MDPS_EXT_TWO-NFMAT.
WRITE:/ 'New Value:', ld_input.

*Conversion exit MATN1, internal->external for field BAUGR CALL FUNCTION 'CONVERSION_EXIT_MATN1_OUTPUT' EXPORTING input = WA_PPH_MDPS_EXT_TWO-BAUGR IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_PPH_MDPS_EXT_TWO-BAUGR.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field KDAUF CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_PPH_MDPS_EXT_TWO-KDAUF IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_PPH_MDPS_EXT_TWO-KDAUF.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ABPSP, internal->external for field PSPEL CALL FUNCTION 'CONVERSION_EXIT_ABPSP_OUTPUT' EXPORTING input = WA_PPH_MDPS_EXT_TWO-PSPEL IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_PPH_MDPS_EXT_TWO-PSPEL.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field AUFNR CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_PPH_MDPS_EXT_TWO-AUFNR IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_PPH_MDPS_EXT_TWO-AUFNR.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field QUNUM CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_PPH_MDPS_EXT_TWO-QUNUM IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_PPH_MDPS_EXT_TWO-QUNUM.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field LIFNR CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_PPH_MDPS_EXT_TWO-LIFNR IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_PPH_MDPS_EXT_TWO-LIFNR.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field EBELN CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_PPH_MDPS_EXT_TWO-EBELN IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_PPH_MDPS_EXT_TWO-EBELN.
WRITE:/ 'New Value:', ld_input.

*Conversion exit MATN1, internal->external for field EMATN CALL FUNCTION 'CONVERSION_EXIT_MATN1_OUTPUT' EXPORTING input = WA_PPH_MDPS_EXT_TWO-EMATN IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_PPH_MDPS_EXT_TWO-EMATN.
WRITE:/ 'New Value:', ld_input.

*Conversion exit NUMCV, internal->external for field STLNR CALL FUNCTION 'CONVERSION_EXIT_NUMCV_OUTPUT' EXPORTING input = WA_PPH_MDPS_EXT_TWO-STLNR IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_PPH_MDPS_EXT_TWO-STLNR.
WRITE:/ 'New Value:', ld_input.

*Conversion exit CUNIT, internal->external for field MDBS_BSTME CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_PPH_MDPS_EXT_TWO-MDBS_BSTME IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_PPH_MDPS_EXT_TWO-MDBS_BSTME.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field EBAN_REVNO CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_PPH_MDPS_EXT_TWO-EBAN_REVNO IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_PPH_MDPS_EXT_TWO-EBAN_REVNO.
WRITE:/ 'New Value:', ld_input.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_PPH_MDPS_EXT_TWO_STR,
MANDT TYPE STRING,
MATNR TYPE STRING,
WERKS TYPE STRING,
BERID TYPE STRING,
DAT00 TYPE STRING,
SORT1 TYPE STRING,
SORT2 TYPE STRING,
DELKZ TYPE STRING,
VRFKZ TYPE STRING,
PLUMI TYPE STRING,
MNG01 TYPE STRING,
MNG02 TYPE STRING,
MNG03 TYPE STRING,
MNG04 TYPE STRING,
DAT01 TYPE STRING,
DAT02 TYPE STRING,
DAT03 TYPE STRING,
PERKZ TYPE STRING,
WEBAZ TYPE STRING,
FIX01 TYPE STRING,
FIX02 TYPE STRING,
BAART TYPE STRING,
PLART TYPE STRING,
BESKZ TYPE STRING,
SOBES TYPE STRING,
UMSKZ TYPE STRING,
WRK01 TYPE STRING,
WRK02 TYPE STRING,
LGORT TYPE STRING,
CHARG TYPE STRING,
LSOBS TYPE STRING,
DELNR TYPE STRING,
DEL12 TYPE STRING,
DELPS TYPE STRING,
DELET TYPE STRING,
VPZUO TYPE STRING,
ZUVKZ TYPE STRING,
VERVP TYPE STRING,
VERSB TYPE STRING,
RSNUM TYPE STRING,
SERNR TYPE STRING,
PALTR TYPE STRING,
TECHS TYPE STRING,
REVLV TYPE STRING,
VERID TYPE STRING,
STLAN TYPE STRING,
STALT TYPE STRING,
STSTA TYPE STRING,
NFPKZ TYPE STRING,
KZAUS TYPE STRING,
NFEAG TYPE STRING,
NFGRP TYPE STRING,
NAFKZ TYPE STRING,
NFMNG TYPE STRING,
NFMAT TYPE STRING,
DELVR TYPE STRING,
AUFVR TYPE STRING,
POSVR TYPE STRING,
EINVR TYPE STRING,
BAUGR TYPE STRING,
KNTTP TYPE STRING,
KZVBR TYPE STRING,
SOBKZ TYPE STRING,
KDAUF TYPE STRING,
KDPOS TYPE STRING,
PSPEL TYPE STRING,
CUOBJ TYPE STRING,
AUFNR TYPE STRING,
VERTO TYPE STRING,
QUNUM TYPE STRING,
QUPOS TYPE STRING,
LIFNR TYPE STRING,
EKORG TYPE STRING,
EBELN TYPE STRING,
EBELP TYPE STRING,
VRTYP TYPE STRING,
BEDAT TYPE STRING,
ETMEN TYPE STRING,
GLMNG TYPE STRING,
FRTHW TYPE STRING,
BEDID TYPE STRING,
TRMER TYPE STRING,
RATID TYPE STRING,
RATER TYPE STRING,
GROID TYPE STRING,
GROER TYPE STRING,
AUFTM TYPE STRING,
ARSNR TYPE STRING,
ARSPS TYPE STRING,
PRNKZ TYPE STRING,
KAPFX TYPE STRING,
PSTTI TYPE STRING,
PEDTI TYPE STRING,
XFEHL TYPE STRING,
MONKZ TYPE STRING,
MDFST TYPE STRING,
VRPLA TYPE STRING,
PBDNR TYPE STRING,
KZBWS TYPE STRING,
MDMNG TYPE STRING,
WAMNG TYPE STRING,
EDGNO TYPE STRING,
TPMNG TYPE STRING,
EMATN TYPE STRING,
PRSCH TYPE STRING,
LVSCH TYPE STRING,
DBSKZ TYPE STRING,
STLTY TYPE STRING,
STLNR TYPE STRING,
STLKN TYPE STRING,
STPOZ TYPE STRING,
PLIFZ TYPE STRING,
PSTMP TYPE STRING,
EXTNL TYPE STRING,
STAEX TYPE STRING,
RESLO TYPE STRING,
PRIO_URG TYPE STRING,
PRIO_REQ TYPE STRING,
XT_RSSTA TYPE STRING,
XT_UMSOK TYPE STRING,
XT_STATU TYPE STRING,
MDBS_BSTME TYPE STRING,
EBAN_ESTKZ TYPE STRING,
EBAN_FRGKZ TYPE STRING,
EBAN_REVNO TYPE STRING,
MARD_DISKZ TYPE STRING,
MARD_BSKFL TYPE STRING,
XT_MENGE_DB TYPE STRING,
XT_WEMNG_DB TYPE STRING,
MDBS_DABMG_DB TYPE STRING,
AFPO_KRSNR TYPE STRING,
AFPO_KRSPS TYPE STRING,
XT_KZFIX TYPE STRING,
XT_ETFZ1 TYPE STRING,
XT_ETFZ2 TYPE STRING,END OF T_EKKO_STR. DATA: WA_PPH_MDPS_EXT_TWO_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_PPH_MDPS_EXT_TWO_STR-MANDT sy-vline
WA_PPH_MDPS_EXT_TWO_STR-MATNR sy-vline
WA_PPH_MDPS_EXT_TWO_STR-WERKS sy-vline
WA_PPH_MDPS_EXT_TWO_STR-BERID sy-vline
WA_PPH_MDPS_EXT_TWO_STR-DAT00 sy-vline
WA_PPH_MDPS_EXT_TWO_STR-SORT1 sy-vline
WA_PPH_MDPS_EXT_TWO_STR-SORT2 sy-vline
WA_PPH_MDPS_EXT_TWO_STR-DELKZ sy-vline
WA_PPH_MDPS_EXT_TWO_STR-VRFKZ sy-vline
WA_PPH_MDPS_EXT_TWO_STR-PLUMI sy-vline
WA_PPH_MDPS_EXT_TWO_STR-MNG01 sy-vline
WA_PPH_MDPS_EXT_TWO_STR-MNG02 sy-vline
WA_PPH_MDPS_EXT_TWO_STR-MNG03 sy-vline
WA_PPH_MDPS_EXT_TWO_STR-MNG04 sy-vline
WA_PPH_MDPS_EXT_TWO_STR-DAT01 sy-vline
WA_PPH_MDPS_EXT_TWO_STR-DAT02 sy-vline
WA_PPH_MDPS_EXT_TWO_STR-DAT03 sy-vline
WA_PPH_MDPS_EXT_TWO_STR-PERKZ sy-vline
WA_PPH_MDPS_EXT_TWO_STR-WEBAZ sy-vline
WA_PPH_MDPS_EXT_TWO_STR-FIX01 sy-vline
WA_PPH_MDPS_EXT_TWO_STR-FIX02 sy-vline
WA_PPH_MDPS_EXT_TWO_STR-BAART sy-vline
WA_PPH_MDPS_EXT_TWO_STR-PLART sy-vline
WA_PPH_MDPS_EXT_TWO_STR-BESKZ sy-vline
WA_PPH_MDPS_EXT_TWO_STR-SOBES sy-vline
WA_PPH_MDPS_EXT_TWO_STR-UMSKZ sy-vline
WA_PPH_MDPS_EXT_TWO_STR-WRK01 sy-vline
WA_PPH_MDPS_EXT_TWO_STR-WRK02 sy-vline
WA_PPH_MDPS_EXT_TWO_STR-LGORT sy-vline
WA_PPH_MDPS_EXT_TWO_STR-CHARG sy-vline
WA_PPH_MDPS_EXT_TWO_STR-LSOBS sy-vline
WA_PPH_MDPS_EXT_TWO_STR-DELNR sy-vline
WA_PPH_MDPS_EXT_TWO_STR-DEL12 sy-vline
WA_PPH_MDPS_EXT_TWO_STR-DELPS sy-vline
WA_PPH_MDPS_EXT_TWO_STR-DELET sy-vline
WA_PPH_MDPS_EXT_TWO_STR-VPZUO sy-vline
WA_PPH_MDPS_EXT_TWO_STR-ZUVKZ sy-vline
WA_PPH_MDPS_EXT_TWO_STR-VERVP sy-vline
WA_PPH_MDPS_EXT_TWO_STR-VERSB sy-vline
WA_PPH_MDPS_EXT_TWO_STR-RSNUM sy-vline
WA_PPH_MDPS_EXT_TWO_STR-SERNR sy-vline
WA_PPH_MDPS_EXT_TWO_STR-PALTR sy-vline
WA_PPH_MDPS_EXT_TWO_STR-TECHS sy-vline
WA_PPH_MDPS_EXT_TWO_STR-REVLV sy-vline
WA_PPH_MDPS_EXT_TWO_STR-VERID sy-vline
WA_PPH_MDPS_EXT_TWO_STR-STLAN sy-vline
WA_PPH_MDPS_EXT_TWO_STR-STALT sy-vline
WA_PPH_MDPS_EXT_TWO_STR-STSTA sy-vline
WA_PPH_MDPS_EXT_TWO_STR-NFPKZ sy-vline
WA_PPH_MDPS_EXT_TWO_STR-KZAUS sy-vline
WA_PPH_MDPS_EXT_TWO_STR-NFEAG sy-vline
WA_PPH_MDPS_EXT_TWO_STR-NFGRP sy-vline
WA_PPH_MDPS_EXT_TWO_STR-NAFKZ sy-vline
WA_PPH_MDPS_EXT_TWO_STR-NFMNG sy-vline
WA_PPH_MDPS_EXT_TWO_STR-NFMAT sy-vline
WA_PPH_MDPS_EXT_TWO_STR-DELVR sy-vline
WA_PPH_MDPS_EXT_TWO_STR-AUFVR sy-vline
WA_PPH_MDPS_EXT_TWO_STR-POSVR sy-vline
WA_PPH_MDPS_EXT_TWO_STR-EINVR sy-vline
WA_PPH_MDPS_EXT_TWO_STR-BAUGR sy-vline
WA_PPH_MDPS_EXT_TWO_STR-KNTTP sy-vline
WA_PPH_MDPS_EXT_TWO_STR-KZVBR sy-vline
WA_PPH_MDPS_EXT_TWO_STR-SOBKZ sy-vline
WA_PPH_MDPS_EXT_TWO_STR-KDAUF sy-vline
WA_PPH_MDPS_EXT_TWO_STR-KDPOS sy-vline
WA_PPH_MDPS_EXT_TWO_STR-PSPEL sy-vline
WA_PPH_MDPS_EXT_TWO_STR-CUOBJ sy-vline
WA_PPH_MDPS_EXT_TWO_STR-AUFNR sy-vline
WA_PPH_MDPS_EXT_TWO_STR-VERTO sy-vline
WA_PPH_MDPS_EXT_TWO_STR-QUNUM sy-vline
WA_PPH_MDPS_EXT_TWO_STR-QUPOS sy-vline
WA_PPH_MDPS_EXT_TWO_STR-LIFNR sy-vline
WA_PPH_MDPS_EXT_TWO_STR-EKORG sy-vline
WA_PPH_MDPS_EXT_TWO_STR-EBELN sy-vline
WA_PPH_MDPS_EXT_TWO_STR-EBELP sy-vline
WA_PPH_MDPS_EXT_TWO_STR-VRTYP sy-vline
WA_PPH_MDPS_EXT_TWO_STR-BEDAT sy-vline
WA_PPH_MDPS_EXT_TWO_STR-ETMEN sy-vline
WA_PPH_MDPS_EXT_TWO_STR-GLMNG sy-vline
WA_PPH_MDPS_EXT_TWO_STR-FRTHW sy-vline
WA_PPH_MDPS_EXT_TWO_STR-BEDID sy-vline
WA_PPH_MDPS_EXT_TWO_STR-TRMER sy-vline
WA_PPH_MDPS_EXT_TWO_STR-RATID sy-vline
WA_PPH_MDPS_EXT_TWO_STR-RATER sy-vline
WA_PPH_MDPS_EXT_TWO_STR-GROID sy-vline
WA_PPH_MDPS_EXT_TWO_STR-GROER sy-vline
WA_PPH_MDPS_EXT_TWO_STR-AUFTM sy-vline
WA_PPH_MDPS_EXT_TWO_STR-ARSNR sy-vline
WA_PPH_MDPS_EXT_TWO_STR-ARSPS sy-vline
WA_PPH_MDPS_EXT_TWO_STR-PRNKZ sy-vline
WA_PPH_MDPS_EXT_TWO_STR-KAPFX sy-vline
WA_PPH_MDPS_EXT_TWO_STR-PSTTI sy-vline
WA_PPH_MDPS_EXT_TWO_STR-PEDTI sy-vline
WA_PPH_MDPS_EXT_TWO_STR-XFEHL sy-vline
WA_PPH_MDPS_EXT_TWO_STR-MONKZ sy-vline
WA_PPH_MDPS_EXT_TWO_STR-MDFST sy-vline
WA_PPH_MDPS_EXT_TWO_STR-VRPLA sy-vline
WA_PPH_MDPS_EXT_TWO_STR-PBDNR sy-vline
WA_PPH_MDPS_EXT_TWO_STR-KZBWS sy-vline
WA_PPH_MDPS_EXT_TWO_STR-MDMNG sy-vline
WA_PPH_MDPS_EXT_TWO_STR-WAMNG sy-vline
WA_PPH_MDPS_EXT_TWO_STR-EDGNO sy-vline
WA_PPH_MDPS_EXT_TWO_STR-TPMNG sy-vline
WA_PPH_MDPS_EXT_TWO_STR-EMATN sy-vline
WA_PPH_MDPS_EXT_TWO_STR-PRSCH sy-vline
WA_PPH_MDPS_EXT_TWO_STR-LVSCH sy-vline
WA_PPH_MDPS_EXT_TWO_STR-DBSKZ sy-vline
WA_PPH_MDPS_EXT_TWO_STR-STLTY sy-vline
WA_PPH_MDPS_EXT_TWO_STR-STLNR sy-vline
WA_PPH_MDPS_EXT_TWO_STR-STLKN sy-vline
WA_PPH_MDPS_EXT_TWO_STR-STPOZ sy-vline
WA_PPH_MDPS_EXT_TWO_STR-PLIFZ sy-vline
WA_PPH_MDPS_EXT_TWO_STR-PSTMP sy-vline
WA_PPH_MDPS_EXT_TWO_STR-EXTNL sy-vline
WA_PPH_MDPS_EXT_TWO_STR-STAEX sy-vline
WA_PPH_MDPS_EXT_TWO_STR-RESLO sy-vline
WA_PPH_MDPS_EXT_TWO_STR-PRIO_URG sy-vline
WA_PPH_MDPS_EXT_TWO_STR-PRIO_REQ sy-vline
WA_PPH_MDPS_EXT_TWO_STR-XT_RSSTA sy-vline
WA_PPH_MDPS_EXT_TWO_STR-XT_UMSOK sy-vline
WA_PPH_MDPS_EXT_TWO_STR-XT_STATU sy-vline
WA_PPH_MDPS_EXT_TWO_STR-MDBS_BSTME sy-vline
WA_PPH_MDPS_EXT_TWO_STR-EBAN_ESTKZ sy-vline
WA_PPH_MDPS_EXT_TWO_STR-EBAN_FRGKZ sy-vline
WA_PPH_MDPS_EXT_TWO_STR-EBAN_REVNO sy-vline
WA_PPH_MDPS_EXT_TWO_STR-MARD_DISKZ sy-vline
WA_PPH_MDPS_EXT_TWO_STR-MARD_BSKFL sy-vline
WA_PPH_MDPS_EXT_TWO_STR-XT_MENGE_DB sy-vline
WA_PPH_MDPS_EXT_TWO_STR-XT_WEMNG_DB sy-vline
WA_PPH_MDPS_EXT_TWO_STR-MDBS_DABMG_DB sy-vline
WA_PPH_MDPS_EXT_TWO_STR-AFPO_KRSNR sy-vline
WA_PPH_MDPS_EXT_TWO_STR-AFPO_KRSPS sy-vline
WA_PPH_MDPS_EXT_TWO_STR-XT_KZFIX sy-vline
WA_PPH_MDPS_EXT_TWO_STR-XT_ETFZ1 sy-vline
WA_PPH_MDPS_EXT_TWO_STR-XT_ETFZ2 sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.