ABAP Select data from SAP table PPH_MDPS_ABAP_EXT into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP PPH_MDPS_ABAP_EXT table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to PPH_MDPS_ABAP_EXT. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the PPH_MDPS_ABAP_EXT table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_PPH_MDPS_ABAP_EXT TYPE STANDARD TABLE OF PPH_MDPS_ABAP_EXT,
      WA_PPH_MDPS_ABAP_EXT TYPE PPH_MDPS_ABAP_EXT,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: <PPH_MDPS_ABAP_EXT> TYPE PPH_MDPS_ABAP_EXT.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_PPH_MDPS_ABAP_EXT.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM PPH_MDPS_ABAP_EXT
  INTO TABLE IT_PPH_MDPS_ABAP_EXT.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM PPH_MDPS_ABAP_EXT
*  INTO TABLE @DATA(IT_PPH_MDPS_ABAP_EXT2).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_PPH_MDPS_ABAP_EXT INDEX 1 INTO DATA(WA_PPH_MDPS_ABAP_EXT2).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_PPH_MDPS_ABAP_EXT ASSIGNING <PPH_MDPS_ABAP_EXT>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
<PPH_MDPS_ABAP_EXT>-MATNR = 1.
<PPH_MDPS_ABAP_EXT>-WERKS = 1.
<PPH_MDPS_ABAP_EXT>-BERID = 1.
<PPH_MDPS_ABAP_EXT>-PLAAB = 1.
<PPH_MDPS_ABAP_EXT>-PLANR = 1.
ENDLOOP.

LOOP AT IT_PPH_MDPS_ABAP_EXT INTO WA_PPH_MDPS_ABAP_EXT.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_PPH_MDPS_ABAP_EXT-DAT00, sy-vline,
WA_PPH_MDPS_ABAP_EXT-TAG00, sy-vline,
WA_PPH_MDPS_ABAP_EXT-SORT1, sy-vline,
WA_PPH_MDPS_ABAP_EXT-SORT2, sy-vline,
WA_PPH_MDPS_ABAP_EXT-DELKZ, sy-vline,
WA_PPH_MDPS_ABAP_EXT-VSTAT, sy-vline.
ENDLOOP. *Add any further fields from structure WA_PPH_MDPS_ABAP_EXT you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_PPH_MDPS_ABAP_EXT TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_PPH_MDPS_ABAP_EXT INTO WA_PPH_MDPS_ABAP_EXT. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.

*Conversion exit MATN1, internal->external for field MATNR CALL FUNCTION 'CONVERSION_EXIT_MATN1_OUTPUT' EXPORTING input = WA_PPH_MDPS_ABAP_EXT-MATNR IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_PPH_MDPS_ABAP_EXT-MATNR.
WRITE:/ 'New Value:', ld_input.

*Conversion exit NUMCV, internal->external for field REVLV CALL FUNCTION 'CONVERSION_EXIT_NUMCV_OUTPUT' EXPORTING input = WA_PPH_MDPS_ABAP_EXT-REVLV IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_PPH_MDPS_ABAP_EXT-REVLV.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field STALT CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_PPH_MDPS_ABAP_EXT-STALT IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_PPH_MDPS_ABAP_EXT-STALT.
WRITE:/ 'New Value:', ld_input.

*Conversion exit MATN1, internal->external for field NFMAT CALL FUNCTION 'CONVERSION_EXIT_MATN1_OUTPUT' EXPORTING input = WA_PPH_MDPS_ABAP_EXT-NFMAT IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_PPH_MDPS_ABAP_EXT-NFMAT.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field AENNR CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_PPH_MDPS_ABAP_EXT-AENNR IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_PPH_MDPS_ABAP_EXT-AENNR.
WRITE:/ 'New Value:', ld_input.

*Conversion exit MATN1, internal->external for field BAUGR CALL FUNCTION 'CONVERSION_EXIT_MATN1_OUTPUT' EXPORTING input = WA_PPH_MDPS_ABAP_EXT-BAUGR IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_PPH_MDPS_ABAP_EXT-BAUGR.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field KDAUF CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_PPH_MDPS_ABAP_EXT-KDAUF IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_PPH_MDPS_ABAP_EXT-KDAUF.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ABPSP, internal->external for field PSPEL CALL FUNCTION 'CONVERSION_EXIT_ABPSP_OUTPUT' EXPORTING input = WA_PPH_MDPS_ABAP_EXT-PSPEL IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_PPH_MDPS_ABAP_EXT-PSPEL.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field AUFNR CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_PPH_MDPS_ABAP_EXT-AUFNR IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_PPH_MDPS_ABAP_EXT-AUFNR.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field QUNUM CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_PPH_MDPS_ABAP_EXT-QUNUM IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_PPH_MDPS_ABAP_EXT-QUNUM.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field LIFNR CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_PPH_MDPS_ABAP_EXT-LIFNR IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_PPH_MDPS_ABAP_EXT-LIFNR.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field EBELN CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_PPH_MDPS_ABAP_EXT-EBELN IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_PPH_MDPS_ABAP_EXT-EBELN.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field KUNNR CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_PPH_MDPS_ABAP_EXT-KUNNR IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_PPH_MDPS_ABAP_EXT-KUNNR.
WRITE:/ 'New Value:', ld_input.

*Conversion exit MATN1, internal->external for field EMATN CALL FUNCTION 'CONVERSION_EXIT_MATN1_OUTPUT' EXPORTING input = WA_PPH_MDPS_ABAP_EXT-EMATN IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_PPH_MDPS_ABAP_EXT-EMATN.
WRITE:/ 'New Value:', ld_input.

*Conversion exit CUNIT, internal->external for field ERFME CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_PPH_MDPS_ABAP_EXT-ERFME IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_PPH_MDPS_ABAP_EXT-ERFME.
WRITE:/ 'New Value:', ld_input.

*Conversion exit NUMCV, internal->external for field STLNR CALL FUNCTION 'CONVERSION_EXIT_NUMCV_OUTPUT' EXPORTING input = WA_PPH_MDPS_ABAP_EXT-STLNR IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_PPH_MDPS_ABAP_EXT-STLNR.
WRITE:/ 'New Value:', ld_input.

*Conversion exit MATN1, internal->external for field MDMAT CALL FUNCTION 'CONVERSION_EXIT_MATN1_OUTPUT' EXPORTING input = WA_PPH_MDPS_ABAP_EXT-MDMAT IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_PPH_MDPS_ABAP_EXT-MDMAT.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field SRM_CONTRACT_ID CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_PPH_MDPS_ABAP_EXT-SRM_CONTRACT_ID IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_PPH_MDPS_ABAP_EXT-SRM_CONTRACT_ID.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field VBELN CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_PPH_MDPS_ABAP_EXT-VBELN IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_PPH_MDPS_ABAP_EXT-VBELN.
WRITE:/ 'New Value:', ld_input.

*Conversion exit MATN1, internal->external for field MPNMT CALL FUNCTION 'CONVERSION_EXIT_MATN1_OUTPUT' EXPORTING input = WA_PPH_MDPS_ABAP_EXT-MPNMT IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_PPH_MDPS_ABAP_EXT-MPNMT.
WRITE:/ 'New Value:', ld_input.

*Conversion exit CUNIT, internal->external for field MDBS_BSTME CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_PPH_MDPS_ABAP_EXT-MDBS_BSTME IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_PPH_MDPS_ABAP_EXT-MDBS_BSTME.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field EBAN_REVNO CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_PPH_MDPS_ABAP_EXT-EBAN_REVNO IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_PPH_MDPS_ABAP_EXT-EBAN_REVNO.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field XT_KONNR CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_PPH_MDPS_ABAP_EXT-XT_KONNR IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_PPH_MDPS_ABAP_EXT-XT_KONNR.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field XT_INFNR CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_PPH_MDPS_ABAP_EXT-XT_INFNR IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_PPH_MDPS_ABAP_EXT-XT_INFNR.
WRITE:/ 'New Value:', ld_input.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_PPH_MDPS_ABAP_EXT_STR,
MATNR TYPE STRING,
WERKS TYPE STRING,
BERID TYPE STRING,
PLAAB TYPE STRING,
PLANR TYPE STRING,
DAT00 TYPE STRING,
TAG00 TYPE STRING,
SORT1 TYPE STRING,
SORT2 TYPE STRING,
DELKZ TYPE STRING,
VSTAT TYPE STRING,
VRFKZ TYPE STRING,
PLUMI TYPE STRING,
MNG01 TYPE STRING,
MNG02 TYPE STRING,
MNG03 TYPE STRING,
MNG04 TYPE STRING,
DAT01 TYPE STRING,
DAT02 TYPE STRING,
DAT03 TYPE STRING,
PERKZ TYPE STRING,
PRPER TYPE STRING,
WEBAZ TYPE STRING,
UKZ01 TYPE STRING,
UMDAT TYPE STRING,
UMDA2 TYPE STRING,
RDMNG TYPE STRING,
FIX01 TYPE STRING,
FIX02 TYPE STRING,
BAART TYPE STRING,
PLART TYPE STRING,
BESKZ TYPE STRING,
SOBES TYPE STRING,
ESOBS TYPE STRING,
UMSKZ TYPE STRING,
AUSSL TYPE STRING,
OLDSL TYPE STRING,
ABEKZ TYPE STRING,
WRK01 TYPE STRING,
WRK02 TYPE STRING,
LGORT TYPE STRING,
CHARG TYPE STRING,
LSOBS TYPE STRING,
DELNR TYPE STRING,
DEL12 TYPE STRING,
DELPS TYPE STRING,
DELET TYPE STRING,
VPZUO TYPE STRING,
ZUVKZ TYPE STRING,
VERVP TYPE STRING,
VERSB TYPE STRING,
AKTAL TYPE STRING,
RSNUM TYPE STRING,
SERNR TYPE STRING,
PALTR TYPE STRING,
TECHS TYPE STRING,
REVLV TYPE STRING,
VERID TYPE STRING,
STLAN TYPE STRING,
STALT TYPE STRING,
STSTA TYPE STRING,
NFPKZ TYPE STRING,
KZAUS TYPE STRING,
NFEAG TYPE STRING,
NFGRP TYPE STRING,
NAFKZ TYPE STRING,
NFMNG TYPE STRING,
NFMAT TYPE STRING,
AENNR TYPE STRING,
DELVR TYPE STRING,
AUFVR TYPE STRING,
POSVR TYPE STRING,
EINVR TYPE STRING,
BAUGR TYPE STRING,
KNTTP TYPE STRING,
KZVBR TYPE STRING,
SOBKZ TYPE STRING,
KDAUF TYPE STRING,
KDPOS TYPE STRING,
PSPEL TYPE STRING,
CUOBJ TYPE STRING,
AUFNR TYPE STRING,
VERTO TYPE STRING,
QUNUM TYPE STRING,
QUPOS TYPE STRING,
LIFNR TYPE STRING,
EKORG TYPE STRING,
EBELN TYPE STRING,
EBELP TYPE STRING,
VRTYP TYPE STRING,
AUTET TYPE STRING,
BEDAT TYPE STRING,
ETMEN TYPE STRING,
GLMNG TYPE STRING,
FRTHW TYPE STRING,
AKTFT TYPE STRING,
BEDID TYPE STRING,
TRMER TYPE STRING,
AKTRT TYPE STRING,
RATID TYPE STRING,
RATER TYPE STRING,
AKTGT TYPE STRING,
GROID TYPE STRING,
GROER TYPE STRING,
AUFTM TYPE STRING,
ARSNR TYPE STRING,
ARSPS TYPE STRING,
PRNKZ TYPE STRING,
KAPFX TYPE STRING,
PSTTI TYPE STRING,
PEDTI TYPE STRING,
RSART TYPE STRING,
XFEHL TYPE STRING,
MONKZ TYPE STRING,
MDFST TYPE STRING,
VRPLA TYPE STRING,
PBDNR TYPE STRING,
KUNNR TYPE STRING,
KZBWS TYPE STRING,
MDMNG TYPE STRING,
WAMNG TYPE STRING,
EDGNO TYPE STRING,
TPMNG TYPE STRING,
EMATN TYPE STRING,
UMREZ TYPE STRING,
UMREN TYPE STRING,
ERFME TYPE STRING,
ERFMG TYPE STRING,
PRSCH TYPE STRING,
LVSCH TYPE STRING,
DBSKZ TYPE STRING,
STLTY TYPE STRING,
STLNR TYPE STRING,
STLKN TYPE STRING,
STPOZ TYPE STRING,
EKGRP TYPE STRING,
MATKL TYPE STRING,
PLIFZ TYPE STRING,
PSTMP TYPE STRING,
EXTNL TYPE STRING,
ADINF TYPE STRING,
STAEX TYPE STRING,
RESLO TYPE STRING,
PRIO_URG TYPE STRING,
PRIO_REQ TYPE STRING,
MDMAT TYPE STRING,
MDLOC TYPE STRING,
MDWRK TYPE STRING,
MDBER TYPE STRING,
SRM_CONTRACT_ID TYPE STRING,
SRM_CONTRACT_ITM TYPE STRING,
SGT_CATV TYPE STRING,
SGT_RCAT TYPE STRING,
SGT_SCAT TYPE STRING,
BOM_VERSN TYPE STRING,
DISUB_SOBKZ TYPE STRING,
IMWERK TYPE STRING,
VBELN TYPE STRING,
ATRKZ TYPE STRING,
M_MRP TYPE STRING,
MPNMT TYPE STRING,
PCMNG TYPE STRING,
PVGUID TYPE STRING,
RESB_UMWRK TYPE STRING,
RESB_SHKZG TYPE STRING,
RESB_DUMPS TYPE STRING,
RESB_BWART TYPE STRING,
XT_RSSTA TYPE STRING,
RESB_SCHGT TYPE STRING,
XT_UMSOK TYPE STRING,
MDUB_BSTYP TYPE STRING,
XT_RETPO TYPE STRING,
XT_LBLKZ TYPE STRING,
XT_LOEKZ TYPE STRING,
XT_AKTNR TYPE STRING,
MDUA_FRGDT TYPE STRING,
MDUA_LBLKZ TYPE STRING,
XT_EMLIF TYPE STRING,
XT_INSMK TYPE STRING,
XT_ITCONS TYPE STRING,
XT_STATU TYPE STRING,
EBAN_PSTYP TYPE STRING,
MDBS_BSTME TYPE STRING,
EBAN_ESTKZ TYPE STRING,
EBAN_FRGKZ TYPE STRING,
EBAN_REVNO TYPE STRING,
EBAN_EXTAPPROVALSTATUS TYPE STRING,
XT_NO_DISP TYPE STRING,
MDPB_PLNKZ TYPE STRING,
MDPB_OPLKZ TYPE STRING,
XT_WEPOS TYPE STRING,
MARD_DISKZ TYPE STRING,
MARD_IS_CONSI TYPE STRING,
MARD_BSKFL TYPE STRING,
XT_STOCK_CAT TYPE STRING,
XT_MENGE_DB TYPE STRING,
XT_WEMNG_DB TYPE STRING,
MDBS_WAMNG_DB TYPE STRING,
MDBS_DABMG_DB TYPE STRING,
MDBS_AMENG TYPE STRING,
MDBS_FIXMG TYPE STRING,
MDBS_EGLKZ TYPE STRING,
MDBS_AMNG01 TYPE STRING,
MDBS_ETDRK TYPE STRING,
AFPO_KRSNR TYPE STRING,
AFPO_KRSPS TYPE STRING,
XT_FLS_RSTO TYPE STRING,
XT_KONNR TYPE STRING,
XT_KTPNR TYPE STRING,
XT_INFNR TYPE STRING,
XT_KZFIX TYPE STRING,
XT_ETFZ1 TYPE STRING,
XT_ETFZ2 TYPE STRING,
DISTR_DONE TYPE STRING,
KNTTP_DB TYPE STRING,
KZVBR_DB TYPE STRING,
KZBWS_DB TYPE STRING,END OF T_EKKO_STR. DATA: WA_PPH_MDPS_ABAP_EXT_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_PPH_MDPS_ABAP_EXT_STR-MATNR sy-vline
WA_PPH_MDPS_ABAP_EXT_STR-WERKS sy-vline
WA_PPH_MDPS_ABAP_EXT_STR-BERID sy-vline
WA_PPH_MDPS_ABAP_EXT_STR-PLAAB sy-vline
WA_PPH_MDPS_ABAP_EXT_STR-PLANR sy-vline
WA_PPH_MDPS_ABAP_EXT_STR-DAT00 sy-vline
WA_PPH_MDPS_ABAP_EXT_STR-TAG00 sy-vline
WA_PPH_MDPS_ABAP_EXT_STR-SORT1 sy-vline
WA_PPH_MDPS_ABAP_EXT_STR-SORT2 sy-vline
WA_PPH_MDPS_ABAP_EXT_STR-DELKZ sy-vline
WA_PPH_MDPS_ABAP_EXT_STR-VSTAT sy-vline
WA_PPH_MDPS_ABAP_EXT_STR-VRFKZ sy-vline
WA_PPH_MDPS_ABAP_EXT_STR-PLUMI sy-vline
WA_PPH_MDPS_ABAP_EXT_STR-MNG01 sy-vline
WA_PPH_MDPS_ABAP_EXT_STR-MNG02 sy-vline
WA_PPH_MDPS_ABAP_EXT_STR-MNG03 sy-vline
WA_PPH_MDPS_ABAP_EXT_STR-MNG04 sy-vline
WA_PPH_MDPS_ABAP_EXT_STR-DAT01 sy-vline
WA_PPH_MDPS_ABAP_EXT_STR-DAT02 sy-vline
WA_PPH_MDPS_ABAP_EXT_STR-DAT03 sy-vline
WA_PPH_MDPS_ABAP_EXT_STR-PERKZ sy-vline
WA_PPH_MDPS_ABAP_EXT_STR-PRPER sy-vline
WA_PPH_MDPS_ABAP_EXT_STR-WEBAZ sy-vline
WA_PPH_MDPS_ABAP_EXT_STR-UKZ01 sy-vline
WA_PPH_MDPS_ABAP_EXT_STR-UMDAT sy-vline
WA_PPH_MDPS_ABAP_EXT_STR-UMDA2 sy-vline
WA_PPH_MDPS_ABAP_EXT_STR-RDMNG sy-vline
WA_PPH_MDPS_ABAP_EXT_STR-FIX01 sy-vline
WA_PPH_MDPS_ABAP_EXT_STR-FIX02 sy-vline
WA_PPH_MDPS_ABAP_EXT_STR-BAART sy-vline
WA_PPH_MDPS_ABAP_EXT_STR-PLART sy-vline
WA_PPH_MDPS_ABAP_EXT_STR-BESKZ sy-vline
WA_PPH_MDPS_ABAP_EXT_STR-SOBES sy-vline
WA_PPH_MDPS_ABAP_EXT_STR-ESOBS sy-vline
WA_PPH_MDPS_ABAP_EXT_STR-UMSKZ sy-vline
WA_PPH_MDPS_ABAP_EXT_STR-AUSSL sy-vline
WA_PPH_MDPS_ABAP_EXT_STR-OLDSL sy-vline
WA_PPH_MDPS_ABAP_EXT_STR-ABEKZ sy-vline
WA_PPH_MDPS_ABAP_EXT_STR-WRK01 sy-vline
WA_PPH_MDPS_ABAP_EXT_STR-WRK02 sy-vline
WA_PPH_MDPS_ABAP_EXT_STR-LGORT sy-vline
WA_PPH_MDPS_ABAP_EXT_STR-CHARG sy-vline
WA_PPH_MDPS_ABAP_EXT_STR-LSOBS sy-vline
WA_PPH_MDPS_ABAP_EXT_STR-DELNR sy-vline
WA_PPH_MDPS_ABAP_EXT_STR-DEL12 sy-vline
WA_PPH_MDPS_ABAP_EXT_STR-DELPS sy-vline
WA_PPH_MDPS_ABAP_EXT_STR-DELET sy-vline
WA_PPH_MDPS_ABAP_EXT_STR-VPZUO sy-vline
WA_PPH_MDPS_ABAP_EXT_STR-ZUVKZ sy-vline
WA_PPH_MDPS_ABAP_EXT_STR-VERVP sy-vline
WA_PPH_MDPS_ABAP_EXT_STR-VERSB sy-vline
WA_PPH_MDPS_ABAP_EXT_STR-AKTAL sy-vline
WA_PPH_MDPS_ABAP_EXT_STR-RSNUM sy-vline
WA_PPH_MDPS_ABAP_EXT_STR-SERNR sy-vline
WA_PPH_MDPS_ABAP_EXT_STR-PALTR sy-vline
WA_PPH_MDPS_ABAP_EXT_STR-TECHS sy-vline
WA_PPH_MDPS_ABAP_EXT_STR-REVLV sy-vline
WA_PPH_MDPS_ABAP_EXT_STR-VERID sy-vline
WA_PPH_MDPS_ABAP_EXT_STR-STLAN sy-vline
WA_PPH_MDPS_ABAP_EXT_STR-STALT sy-vline
WA_PPH_MDPS_ABAP_EXT_STR-STSTA sy-vline
WA_PPH_MDPS_ABAP_EXT_STR-NFPKZ sy-vline
WA_PPH_MDPS_ABAP_EXT_STR-KZAUS sy-vline
WA_PPH_MDPS_ABAP_EXT_STR-NFEAG sy-vline
WA_PPH_MDPS_ABAP_EXT_STR-NFGRP sy-vline
WA_PPH_MDPS_ABAP_EXT_STR-NAFKZ sy-vline
WA_PPH_MDPS_ABAP_EXT_STR-NFMNG sy-vline
WA_PPH_MDPS_ABAP_EXT_STR-NFMAT sy-vline
WA_PPH_MDPS_ABAP_EXT_STR-AENNR sy-vline
WA_PPH_MDPS_ABAP_EXT_STR-DELVR sy-vline
WA_PPH_MDPS_ABAP_EXT_STR-AUFVR sy-vline
WA_PPH_MDPS_ABAP_EXT_STR-POSVR sy-vline
WA_PPH_MDPS_ABAP_EXT_STR-EINVR sy-vline
WA_PPH_MDPS_ABAP_EXT_STR-BAUGR sy-vline
WA_PPH_MDPS_ABAP_EXT_STR-KNTTP sy-vline
WA_PPH_MDPS_ABAP_EXT_STR-KZVBR sy-vline
WA_PPH_MDPS_ABAP_EXT_STR-SOBKZ sy-vline
WA_PPH_MDPS_ABAP_EXT_STR-KDAUF sy-vline
WA_PPH_MDPS_ABAP_EXT_STR-KDPOS sy-vline
WA_PPH_MDPS_ABAP_EXT_STR-PSPEL sy-vline
WA_PPH_MDPS_ABAP_EXT_STR-CUOBJ sy-vline
WA_PPH_MDPS_ABAP_EXT_STR-AUFNR sy-vline
WA_PPH_MDPS_ABAP_EXT_STR-VERTO sy-vline
WA_PPH_MDPS_ABAP_EXT_STR-QUNUM sy-vline
WA_PPH_MDPS_ABAP_EXT_STR-QUPOS sy-vline
WA_PPH_MDPS_ABAP_EXT_STR-LIFNR sy-vline
WA_PPH_MDPS_ABAP_EXT_STR-EKORG sy-vline
WA_PPH_MDPS_ABAP_EXT_STR-EBELN sy-vline
WA_PPH_MDPS_ABAP_EXT_STR-EBELP sy-vline
WA_PPH_MDPS_ABAP_EXT_STR-VRTYP sy-vline
WA_PPH_MDPS_ABAP_EXT_STR-AUTET sy-vline
WA_PPH_MDPS_ABAP_EXT_STR-BEDAT sy-vline
WA_PPH_MDPS_ABAP_EXT_STR-ETMEN sy-vline
WA_PPH_MDPS_ABAP_EXT_STR-GLMNG sy-vline
WA_PPH_MDPS_ABAP_EXT_STR-FRTHW sy-vline
WA_PPH_MDPS_ABAP_EXT_STR-AKTFT sy-vline
WA_PPH_MDPS_ABAP_EXT_STR-BEDID sy-vline
WA_PPH_MDPS_ABAP_EXT_STR-TRMER sy-vline
WA_PPH_MDPS_ABAP_EXT_STR-AKTRT sy-vline
WA_PPH_MDPS_ABAP_EXT_STR-RATID sy-vline
WA_PPH_MDPS_ABAP_EXT_STR-RATER sy-vline
WA_PPH_MDPS_ABAP_EXT_STR-AKTGT sy-vline
WA_PPH_MDPS_ABAP_EXT_STR-GROID sy-vline
WA_PPH_MDPS_ABAP_EXT_STR-GROER sy-vline
WA_PPH_MDPS_ABAP_EXT_STR-AUFTM sy-vline
WA_PPH_MDPS_ABAP_EXT_STR-ARSNR sy-vline
WA_PPH_MDPS_ABAP_EXT_STR-ARSPS sy-vline
WA_PPH_MDPS_ABAP_EXT_STR-PRNKZ sy-vline
WA_PPH_MDPS_ABAP_EXT_STR-KAPFX sy-vline
WA_PPH_MDPS_ABAP_EXT_STR-PSTTI sy-vline
WA_PPH_MDPS_ABAP_EXT_STR-PEDTI sy-vline
WA_PPH_MDPS_ABAP_EXT_STR-RSART sy-vline
WA_PPH_MDPS_ABAP_EXT_STR-XFEHL sy-vline
WA_PPH_MDPS_ABAP_EXT_STR-MONKZ sy-vline
WA_PPH_MDPS_ABAP_EXT_STR-MDFST sy-vline
WA_PPH_MDPS_ABAP_EXT_STR-VRPLA sy-vline
WA_PPH_MDPS_ABAP_EXT_STR-PBDNR sy-vline
WA_PPH_MDPS_ABAP_EXT_STR-KUNNR sy-vline
WA_PPH_MDPS_ABAP_EXT_STR-KZBWS sy-vline
WA_PPH_MDPS_ABAP_EXT_STR-MDMNG sy-vline
WA_PPH_MDPS_ABAP_EXT_STR-WAMNG sy-vline
WA_PPH_MDPS_ABAP_EXT_STR-EDGNO sy-vline
WA_PPH_MDPS_ABAP_EXT_STR-TPMNG sy-vline
WA_PPH_MDPS_ABAP_EXT_STR-EMATN sy-vline
WA_PPH_MDPS_ABAP_EXT_STR-UMREZ sy-vline
WA_PPH_MDPS_ABAP_EXT_STR-UMREN sy-vline
WA_PPH_MDPS_ABAP_EXT_STR-ERFME sy-vline
WA_PPH_MDPS_ABAP_EXT_STR-ERFMG sy-vline
WA_PPH_MDPS_ABAP_EXT_STR-PRSCH sy-vline
WA_PPH_MDPS_ABAP_EXT_STR-LVSCH sy-vline
WA_PPH_MDPS_ABAP_EXT_STR-DBSKZ sy-vline
WA_PPH_MDPS_ABAP_EXT_STR-STLTY sy-vline
WA_PPH_MDPS_ABAP_EXT_STR-STLNR sy-vline
WA_PPH_MDPS_ABAP_EXT_STR-STLKN sy-vline
WA_PPH_MDPS_ABAP_EXT_STR-STPOZ sy-vline
WA_PPH_MDPS_ABAP_EXT_STR-EKGRP sy-vline
WA_PPH_MDPS_ABAP_EXT_STR-MATKL sy-vline
WA_PPH_MDPS_ABAP_EXT_STR-PLIFZ sy-vline
WA_PPH_MDPS_ABAP_EXT_STR-PSTMP sy-vline
WA_PPH_MDPS_ABAP_EXT_STR-EXTNL sy-vline
WA_PPH_MDPS_ABAP_EXT_STR-ADINF sy-vline
WA_PPH_MDPS_ABAP_EXT_STR-STAEX sy-vline
WA_PPH_MDPS_ABAP_EXT_STR-RESLO sy-vline
WA_PPH_MDPS_ABAP_EXT_STR-PRIO_URG sy-vline
WA_PPH_MDPS_ABAP_EXT_STR-PRIO_REQ sy-vline
WA_PPH_MDPS_ABAP_EXT_STR-MDMAT sy-vline
WA_PPH_MDPS_ABAP_EXT_STR-MDLOC sy-vline
WA_PPH_MDPS_ABAP_EXT_STR-MDWRK sy-vline
WA_PPH_MDPS_ABAP_EXT_STR-MDBER sy-vline
WA_PPH_MDPS_ABAP_EXT_STR-SRM_CONTRACT_ID sy-vline
WA_PPH_MDPS_ABAP_EXT_STR-SRM_CONTRACT_ITM sy-vline
WA_PPH_MDPS_ABAP_EXT_STR-SGT_CATV sy-vline
WA_PPH_MDPS_ABAP_EXT_STR-SGT_RCAT sy-vline
WA_PPH_MDPS_ABAP_EXT_STR-SGT_SCAT sy-vline
WA_PPH_MDPS_ABAP_EXT_STR-BOM_VERSN sy-vline
WA_PPH_MDPS_ABAP_EXT_STR-DISUB_SOBKZ sy-vline
WA_PPH_MDPS_ABAP_EXT_STR-IMWERK sy-vline
WA_PPH_MDPS_ABAP_EXT_STR-VBELN sy-vline
WA_PPH_MDPS_ABAP_EXT_STR-ATRKZ sy-vline
WA_PPH_MDPS_ABAP_EXT_STR-M_MRP sy-vline
WA_PPH_MDPS_ABAP_EXT_STR-MPNMT sy-vline
WA_PPH_MDPS_ABAP_EXT_STR-PCMNG sy-vline
WA_PPH_MDPS_ABAP_EXT_STR-PVGUID sy-vline
WA_PPH_MDPS_ABAP_EXT_STR-RESB_UMWRK sy-vline
WA_PPH_MDPS_ABAP_EXT_STR-RESB_SHKZG sy-vline
WA_PPH_MDPS_ABAP_EXT_STR-RESB_DUMPS sy-vline
WA_PPH_MDPS_ABAP_EXT_STR-RESB_BWART sy-vline
WA_PPH_MDPS_ABAP_EXT_STR-XT_RSSTA sy-vline
WA_PPH_MDPS_ABAP_EXT_STR-RESB_SCHGT sy-vline
WA_PPH_MDPS_ABAP_EXT_STR-XT_UMSOK sy-vline
WA_PPH_MDPS_ABAP_EXT_STR-MDUB_BSTYP sy-vline
WA_PPH_MDPS_ABAP_EXT_STR-XT_RETPO sy-vline
WA_PPH_MDPS_ABAP_EXT_STR-XT_LBLKZ sy-vline
WA_PPH_MDPS_ABAP_EXT_STR-XT_LOEKZ sy-vline
WA_PPH_MDPS_ABAP_EXT_STR-XT_AKTNR sy-vline
WA_PPH_MDPS_ABAP_EXT_STR-MDUA_FRGDT sy-vline
WA_PPH_MDPS_ABAP_EXT_STR-MDUA_LBLKZ sy-vline
WA_PPH_MDPS_ABAP_EXT_STR-XT_EMLIF sy-vline
WA_PPH_MDPS_ABAP_EXT_STR-XT_INSMK sy-vline
WA_PPH_MDPS_ABAP_EXT_STR-XT_ITCONS sy-vline
WA_PPH_MDPS_ABAP_EXT_STR-XT_STATU sy-vline
WA_PPH_MDPS_ABAP_EXT_STR-EBAN_PSTYP sy-vline
WA_PPH_MDPS_ABAP_EXT_STR-MDBS_BSTME sy-vline
WA_PPH_MDPS_ABAP_EXT_STR-EBAN_ESTKZ sy-vline
WA_PPH_MDPS_ABAP_EXT_STR-EBAN_FRGKZ sy-vline
WA_PPH_MDPS_ABAP_EXT_STR-EBAN_REVNO sy-vline
WA_PPH_MDPS_ABAP_EXT_STR-EBAN_EXTAPPROVALSTATUS sy-vline
WA_PPH_MDPS_ABAP_EXT_STR-XT_NO_DISP sy-vline
WA_PPH_MDPS_ABAP_EXT_STR-MDPB_PLNKZ sy-vline
WA_PPH_MDPS_ABAP_EXT_STR-MDPB_OPLKZ sy-vline
WA_PPH_MDPS_ABAP_EXT_STR-XT_WEPOS sy-vline
WA_PPH_MDPS_ABAP_EXT_STR-MARD_DISKZ sy-vline
WA_PPH_MDPS_ABAP_EXT_STR-MARD_IS_CONSI sy-vline
WA_PPH_MDPS_ABAP_EXT_STR-MARD_BSKFL sy-vline
WA_PPH_MDPS_ABAP_EXT_STR-XT_STOCK_CAT sy-vline
WA_PPH_MDPS_ABAP_EXT_STR-XT_MENGE_DB sy-vline
WA_PPH_MDPS_ABAP_EXT_STR-XT_WEMNG_DB sy-vline
WA_PPH_MDPS_ABAP_EXT_STR-MDBS_WAMNG_DB sy-vline
WA_PPH_MDPS_ABAP_EXT_STR-MDBS_DABMG_DB sy-vline
WA_PPH_MDPS_ABAP_EXT_STR-MDBS_AMENG sy-vline
WA_PPH_MDPS_ABAP_EXT_STR-MDBS_FIXMG sy-vline
WA_PPH_MDPS_ABAP_EXT_STR-MDBS_EGLKZ sy-vline
WA_PPH_MDPS_ABAP_EXT_STR-MDBS_AMNG01 sy-vline
WA_PPH_MDPS_ABAP_EXT_STR-MDBS_ETDRK sy-vline
WA_PPH_MDPS_ABAP_EXT_STR-AFPO_KRSNR sy-vline
WA_PPH_MDPS_ABAP_EXT_STR-AFPO_KRSPS sy-vline
WA_PPH_MDPS_ABAP_EXT_STR-XT_FLS_RSTO sy-vline
WA_PPH_MDPS_ABAP_EXT_STR-XT_KONNR sy-vline
WA_PPH_MDPS_ABAP_EXT_STR-XT_KTPNR sy-vline
WA_PPH_MDPS_ABAP_EXT_STR-XT_INFNR sy-vline
WA_PPH_MDPS_ABAP_EXT_STR-XT_KZFIX sy-vline
WA_PPH_MDPS_ABAP_EXT_STR-XT_ETFZ1 sy-vline
WA_PPH_MDPS_ABAP_EXT_STR-XT_ETFZ2 sy-vline
WA_PPH_MDPS_ABAP_EXT_STR-DISTR_DONE sy-vline
WA_PPH_MDPS_ABAP_EXT_STR-KNTTP_DB sy-vline
WA_PPH_MDPS_ABAP_EXT_STR-KZVBR_DB sy-vline
WA_PPH_MDPS_ABAP_EXT_STR-KZBWS_DB sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.