ABAP Select data from SAP table PPFSINFXTE into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP PPFSINFXTE table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to PPFSINFXTE. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the PPFSINFXTE table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_PPFSINFXTE TYPE STANDARD TABLE OF PPFSINFXTE,
      WA_PPFSINFXTE TYPE PPFSINFXTE,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: <PPFSINFXTE> TYPE PPFSINFXTE.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_PPFSINFXTE.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM PPFSINFXTE
  INTO TABLE IT_PPFSINFXTE.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM PPFSINFXTE
*  INTO TABLE @DATA(IT_PPFSINFXTE2).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_PPFSINFXTE INDEX 1 INTO DATA(WA_PPFSINFXTE2).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_PPFSINFXTE ASSIGNING <PPFSINFXTE>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
<PPFSINFXTE>-ARCHVMODE = 1.
<PPFSINFXTE>-SMARTFORM = 1.
<PPFSINFXTE>-PROCCLS = 1.
<PPFSINFXTE>-PROCMETH = 1.
<PPFSINFXTE>-CUSTOB_CLS = 1.
ENDLOOP.

LOOP AT IT_PPFSINFXTE INTO WA_PPFSINFXTE.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_PPFSINFXTE-CUSTOB_OID, sy-vline,
WA_PPFSINFXTE-RP_LOGSYST, sy-vline,
WA_PPFSINFXTE-RP_OBJTYPE, sy-vline,
WA_PPFSINFXTE-RP_OBJKEY, sy-vline,
WA_PPFSINFXTE-RP_DESCRIB, sy-vline,
WA_PPFSINFXTE-FAXNO, sy-vline.
ENDLOOP. *Add any further fields from structure WA_PPFSINFXTE you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_PPFSINFXTE TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_PPFSINFXTE INTO WA_PPFSINFXTE. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.

*Conversion exit ALPHA, internal->external for field RP_LOGSYST CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_PPFSINFXTE-RP_LOGSYST IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_PPFSINFXTE-RP_LOGSYST.
WRITE:/ 'New Value:', ld_input.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_PPFSINFXTE_STR,
ARCHVMODE TYPE STRING,
SMARTFORM TYPE STRING,
PROCCLS TYPE STRING,
PROCMETH TYPE STRING,
CUSTOB_CLS TYPE STRING,
CUSTOB_OID TYPE STRING,
RP_LOGSYST TYPE STRING,
RP_OBJTYPE TYPE STRING,
RP_OBJKEY TYPE STRING,
RP_DESCRIB TYPE STRING,
FAXNO TYPE STRING,
FAXCOUNTRY TYPE STRING,
NEXT_CLS TYPE STRING,
NEXT_OID TYPE STRING,
USECUSTDAT TYPE STRING,
INVALID TYPE STRING,END OF T_EKKO_STR. DATA: WA_PPFSINFXTE_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_PPFSINFXTE_STR-ARCHVMODE sy-vline
WA_PPFSINFXTE_STR-SMARTFORM sy-vline
WA_PPFSINFXTE_STR-PROCCLS sy-vline
WA_PPFSINFXTE_STR-PROCMETH sy-vline
WA_PPFSINFXTE_STR-CUSTOB_CLS sy-vline
WA_PPFSINFXTE_STR-CUSTOB_OID sy-vline
WA_PPFSINFXTE_STR-RP_LOGSYST sy-vline
WA_PPFSINFXTE_STR-RP_OBJTYPE sy-vline
WA_PPFSINFXTE_STR-RP_OBJKEY sy-vline
WA_PPFSINFXTE_STR-RP_DESCRIB sy-vline
WA_PPFSINFXTE_STR-FAXNO sy-vline
WA_PPFSINFXTE_STR-FAXCOUNTRY sy-vline
WA_PPFSINFXTE_STR-NEXT_CLS sy-vline
WA_PPFSINFXTE_STR-NEXT_OID sy-vline
WA_PPFSINFXTE_STR-USECUSTDAT sy-vline
WA_PPFSINFXTE_STR-INVALID sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.