ABAP Select data from SAP table PPEPDV_PRACTSEQ into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP PPEPDV_PRACTSEQ table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to PPEPDV_PRACTSEQ. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the PPEPDV_PRACTSEQ table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_PPEPDV_PRACTSEQ TYPE STANDARD TABLE OF PPEPDV_PRACTSEQ,
      WA_PPEPDV_PRACTSEQ TYPE PPEPDV_PRACTSEQ,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: <PPEPDV_PRACTSEQ> TYPE PPEPDV_PRACTSEQ.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_PPEPDV_PRACTSEQ.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM PPEPDV_PRACTSEQ
  INTO TABLE IT_PPEPDV_PRACTSEQ.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM PPEPDV_PRACTSEQ
*  INTO TABLE @DATA(IT_PPEPDV_PRACTSEQ2).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_PPEPDV_PRACTSEQ INDEX 1 INTO DATA(WA_PPEPDV_PRACTSEQ2).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_PPEPDV_PRACTSEQ ASSIGNING <PPEPDV_PRACTSEQ>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
<PPEPDV_PRACTSEQ>-MANDT = 1.
<PPEPDV_PRACTSEQ>-PRGUID = 1.
<PPEPDV_PRACTSEQ>-PRCNT = 1.
<PPEPDV_PRACTSEQ>-TIMSTMP = 1.
<PPEPDV_PRACTSEQ>-AENNR = 1.
ENDLOOP.

LOOP AT IT_PPEPDV_PRACTSEQ INTO WA_PPEPDV_PRACTSEQ.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_PPEPDV_PRACTSEQ-DELFLG, sy-vline,
WA_PPEPDV_PRACTSEQ-OTYPE1, sy-vline,
WA_PPEPDV_PRACTSEQ-GUID1, sy-vline,
WA_PPEPDV_PRACTSEQ-APPLOBJ_TYPE1, sy-vline,
WA_PPEPDV_PRACTSEQ-OTYPE2, sy-vline,
WA_PPEPDV_PRACTSEQ-GUID2, sy-vline.
ENDLOOP. *Add any further fields from structure WA_PPEPDV_PRACTSEQ you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_PPEPDV_PRACTSEQ TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_PPEPDV_PRACTSEQ INTO WA_PPEPDV_PRACTSEQ. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.

*Conversion exit ALPHA, internal->external for field AENNR CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_PPEPDV_PRACTSEQ-AENNR IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_PPEPDV_PRACTSEQ-AENNR.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field LOGSYS CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_PPEPDV_PRACTSEQ-LOGSYS IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_PPEPDV_PRACTSEQ-LOGSYS.
WRITE:/ 'New Value:', ld_input.

*Conversion exit CUNIT, internal->external for field TUNIT_MIN CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_PPEPDV_PRACTSEQ-TUNIT_MIN IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_PPEPDV_PRACTSEQ-TUNIT_MIN.
WRITE:/ 'New Value:', ld_input.

*Conversion exit CUNIT, internal->external for field TUNIT_MAX CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_PPEPDV_PRACTSEQ-TUNIT_MAX IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_PPEPDV_PRACTSEQ-TUNIT_MAX.
WRITE:/ 'New Value:', ld_input.

*Conversion exit CUNIT, internal->external for field TUNIT_AVG CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_PPEPDV_PRACTSEQ-TUNIT_AVG IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_PPEPDV_PRACTSEQ-TUNIT_AVG.
WRITE:/ 'New Value:', ld_input.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_PPEPDV_PRACTSEQ_STR,
MANDT TYPE STRING,
PRGUID TYPE STRING,
PRCNT TYPE STRING,
TIMSTMP TYPE STRING,
AENNR TYPE STRING,
DELFLG TYPE STRING,
OTYPE1 TYPE STRING,
GUID1 TYPE STRING,
APPLOBJ_TYPE1 TYPE STRING,
OTYPE2 TYPE STRING,
GUID2 TYPE STRING,
APPLOBJ_TYPE2 TYPE STRING,
PRTYPE TYPE STRING,
APPLREL_TYPE TYPE STRING,
CREADAT TYPE STRING,
CREABY TYPE STRING,
CHNGDAT TYPE STRING,
CHNGBY TYPE STRING,
LOGSYS TYPE STRING,
CRTYPE TYPE STRING,
COVER_FLG TYPE STRING,
COUPLE_TYPE TYPE STRING,
MATFLOW TYPE STRING,
TUNIT_MIN TYPE STRING,
TUNIT_MAX TYPE STRING,
TUNIT_AVG TYPE STRING,
TUSE_MIN TYPE STRING,
TUSE_MAX TYPE STRING,
SCHED_BY_SUCC TYPE STRING,
TRTIME_MIN TYPE STRING,
TRTIME_MAX TYPE STRING,
TRTIME_AVG TYPE STRING,
ADD_CONSTR TYPE STRING,
ACT_PNAME1 TYPE STRING,
ACT_PNAME2 TYPE STRING,END OF T_EKKO_STR. DATA: WA_PPEPDV_PRACTSEQ_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_PPEPDV_PRACTSEQ_STR-MANDT sy-vline
WA_PPEPDV_PRACTSEQ_STR-PRGUID sy-vline
WA_PPEPDV_PRACTSEQ_STR-PRCNT sy-vline
WA_PPEPDV_PRACTSEQ_STR-TIMSTMP sy-vline
WA_PPEPDV_PRACTSEQ_STR-AENNR sy-vline
WA_PPEPDV_PRACTSEQ_STR-DELFLG sy-vline
WA_PPEPDV_PRACTSEQ_STR-OTYPE1 sy-vline
WA_PPEPDV_PRACTSEQ_STR-GUID1 sy-vline
WA_PPEPDV_PRACTSEQ_STR-APPLOBJ_TYPE1 sy-vline
WA_PPEPDV_PRACTSEQ_STR-OTYPE2 sy-vline
WA_PPEPDV_PRACTSEQ_STR-GUID2 sy-vline
WA_PPEPDV_PRACTSEQ_STR-APPLOBJ_TYPE2 sy-vline
WA_PPEPDV_PRACTSEQ_STR-PRTYPE sy-vline
WA_PPEPDV_PRACTSEQ_STR-APPLREL_TYPE sy-vline
WA_PPEPDV_PRACTSEQ_STR-CREADAT sy-vline
WA_PPEPDV_PRACTSEQ_STR-CREABY sy-vline
WA_PPEPDV_PRACTSEQ_STR-CHNGDAT sy-vline
WA_PPEPDV_PRACTSEQ_STR-CHNGBY sy-vline
WA_PPEPDV_PRACTSEQ_STR-LOGSYS sy-vline
WA_PPEPDV_PRACTSEQ_STR-CRTYPE sy-vline
WA_PPEPDV_PRACTSEQ_STR-COVER_FLG sy-vline
WA_PPEPDV_PRACTSEQ_STR-COUPLE_TYPE sy-vline
WA_PPEPDV_PRACTSEQ_STR-MATFLOW sy-vline
WA_PPEPDV_PRACTSEQ_STR-TUNIT_MIN sy-vline
WA_PPEPDV_PRACTSEQ_STR-TUNIT_MAX sy-vline
WA_PPEPDV_PRACTSEQ_STR-TUNIT_AVG sy-vline
WA_PPEPDV_PRACTSEQ_STR-TUSE_MIN sy-vline
WA_PPEPDV_PRACTSEQ_STR-TUSE_MAX sy-vline
WA_PPEPDV_PRACTSEQ_STR-SCHED_BY_SUCC sy-vline
WA_PPEPDV_PRACTSEQ_STR-TRTIME_MIN sy-vline
WA_PPEPDV_PRACTSEQ_STR-TRTIME_MAX sy-vline
WA_PPEPDV_PRACTSEQ_STR-TRTIME_AVG sy-vline
WA_PPEPDV_PRACTSEQ_STR-ADD_CONSTR sy-vline
WA_PPEPDV_PRACTSEQ_STR-ACT_PNAME1 sy-vline
WA_PPEPDV_PRACTSEQ_STR-ACT_PNAME2 sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.