ABAP Select data from SAP table PPEPDV_HDR into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP PPEPDV_HDR table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to PPEPDV_HDR. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the PPEPDV_HDR table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_PPEPDV_HDR TYPE STANDARD TABLE OF PPEPDV_HDR,
      WA_PPEPDV_HDR TYPE PPEPDV_HDR,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: <PPEPDV_HDR> TYPE PPEPDV_HDR.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_PPEPDV_HDR.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM PPEPDV_HDR
  INTO TABLE IT_PPEPDV_HDR.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM PPEPDV_HDR
*  INTO TABLE @DATA(IT_PPEPDV_HDR2).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_PPEPDV_HDR INDEX 1 INTO DATA(WA_PPEPDV_HDR2).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_PPEPDV_HDR ASSIGNING <PPEPDV_HDR>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
<PPEPDV_HDR>-MANDT = 1.
<PPEPDV_HDR>-PPEGUID = 1.
<PPEPDV_HDR>-OBJID = 1.
<PPEPDV_HDR>-LOCID = 1.
<PPEPDV_HDR>-PPEUSE = 1.
ENDLOOP.

LOOP AT IT_PPEPDV_HDR INTO WA_PPEPDV_HDR.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_PPEPDV_HDR-PPENAME, sy-vline,
WA_PPEPDV_HDR-OBJTYPE, sy-vline,
WA_PPEPDV_HDR-PPETYPE, sy-vline,
WA_PPEPDV_HDR-PPEMATCOOUT, sy-vline,
WA_PPEPDV_HDR-ASSEMBLY_SCRAP, sy-vline,
WA_PPEPDV_HDR-PCOST_MULTI_VAR, sy-vline.
ENDLOOP. *Add any further fields from structure WA_PPEPDV_HDR you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_PPEPDV_HDR TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_PPEPDV_HDR INTO WA_PPEPDV_HDR. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.

*Conversion exit ALPHA, internal->external for field LOGSYS CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_PPEPDV_HDR-LOGSYS IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_PPEPDV_HDR-LOGSYS.
WRITE:/ 'New Value:', ld_input.

*Conversion exit CUNIT, internal->external for field QUNIT CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_PPEPDV_HDR-QUNIT IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_PPEPDV_HDR-QUNIT.
WRITE:/ 'New Value:', ld_input.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_PPEPDV_HDR_STR,
MANDT TYPE STRING,
PPEGUID TYPE STRING,
OBJID TYPE STRING,
LOCID TYPE STRING,
PPEUSE TYPE STRING,
PPENAME TYPE STRING,
OBJTYPE TYPE STRING,
PPETYPE TYPE STRING,
PPEMATCOOUT TYPE STRING,
ASSEMBLY_SCRAP TYPE STRING,
PCOST_MULTI_VAR TYPE STRING,
PCOST_MULTI_FIX TYPE STRING,
PCOST_SINGL_VAR TYPE STRING,
PCOST_PROFILE TYPE STRING,
REL_PDV_INT TYPE STRING,
PDVTYPE TYPE STRING,
TIMSTMP TYPE STRING,
CREADAT TYPE STRING,
CREABY TYPE STRING,
CHNGDAT TYPE STRING,
CHNGBY TYPE STRING,
LOGSYS TYPE STRING,
DELFLG TYPE STRING,
LOCID_PLN TYPE STRING,
VERSION_INT TYPE STRING,
VERSION_TXT TYPE STRING,
DATE_LO TYPE STRING,
DATE_HIGH TYPE STRING,
TIME_LO TYPE STRING,
TIME_HIGH TYPE STRING,
LOCK_MODE TYPE STRING,
QUANT_LO TYPE STRING,
QUANT_HIGH TYPE STRING,
QUNIT TYPE STRING,
PROCPRIO TYPE STRING,
REPEDITIVE_MANU TYPE STRING,
CMPID_CHANGE TYPE STRING,
DISTRIBUTION_KEY TYPE STRING,
PROPOSED_SUBLOC TYPE STRING,
RECEIVING_SUBLOC TYPE STRING,
SUPPLY_AREA TYPE STRING,
CMP_PGUID TYPE STRING,
CMP_OTYPE TYPE STRING,
CMP_PVGUID TYPE STRING,
ACT_PGUID TYPE STRING,
ACT_OTYPE TYPE STRING,
COPTYPE TYPE STRING,
LOCEXT TYPE STRING,
CMPEXT_PD TYPE STRING,
CMPID_TEXT_PD TYPE STRING,
CMPID_TYPE_PD TYPE STRING,
LOCEXT_PD TYPE STRING,
COSTPROF_DUMMY TYPE STRING,
COSTPROF_EXT TYPE STRING,END OF T_EKKO_STR. DATA: WA_PPEPDV_HDR_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_PPEPDV_HDR_STR-MANDT sy-vline
WA_PPEPDV_HDR_STR-PPEGUID sy-vline
WA_PPEPDV_HDR_STR-OBJID sy-vline
WA_PPEPDV_HDR_STR-LOCID sy-vline
WA_PPEPDV_HDR_STR-PPEUSE sy-vline
WA_PPEPDV_HDR_STR-PPENAME sy-vline
WA_PPEPDV_HDR_STR-OBJTYPE sy-vline
WA_PPEPDV_HDR_STR-PPETYPE sy-vline
WA_PPEPDV_HDR_STR-PPEMATCOOUT sy-vline
WA_PPEPDV_HDR_STR-ASSEMBLY_SCRAP sy-vline
WA_PPEPDV_HDR_STR-PCOST_MULTI_VAR sy-vline
WA_PPEPDV_HDR_STR-PCOST_MULTI_FIX sy-vline
WA_PPEPDV_HDR_STR-PCOST_SINGL_VAR sy-vline
WA_PPEPDV_HDR_STR-PCOST_PROFILE sy-vline
WA_PPEPDV_HDR_STR-REL_PDV_INT sy-vline
WA_PPEPDV_HDR_STR-PDVTYPE sy-vline
WA_PPEPDV_HDR_STR-TIMSTMP sy-vline
WA_PPEPDV_HDR_STR-CREADAT sy-vline
WA_PPEPDV_HDR_STR-CREABY sy-vline
WA_PPEPDV_HDR_STR-CHNGDAT sy-vline
WA_PPEPDV_HDR_STR-CHNGBY sy-vline
WA_PPEPDV_HDR_STR-LOGSYS sy-vline
WA_PPEPDV_HDR_STR-DELFLG sy-vline
WA_PPEPDV_HDR_STR-LOCID_PLN sy-vline
WA_PPEPDV_HDR_STR-VERSION_INT sy-vline
WA_PPEPDV_HDR_STR-VERSION_TXT sy-vline
WA_PPEPDV_HDR_STR-DATE_LO sy-vline
WA_PPEPDV_HDR_STR-DATE_HIGH sy-vline
WA_PPEPDV_HDR_STR-TIME_LO sy-vline
WA_PPEPDV_HDR_STR-TIME_HIGH sy-vline
WA_PPEPDV_HDR_STR-LOCK_MODE sy-vline
WA_PPEPDV_HDR_STR-QUANT_LO sy-vline
WA_PPEPDV_HDR_STR-QUANT_HIGH sy-vline
WA_PPEPDV_HDR_STR-QUNIT sy-vline
WA_PPEPDV_HDR_STR-PROCPRIO sy-vline
WA_PPEPDV_HDR_STR-REPEDITIVE_MANU sy-vline
WA_PPEPDV_HDR_STR-CMPID_CHANGE sy-vline
WA_PPEPDV_HDR_STR-DISTRIBUTION_KEY sy-vline
WA_PPEPDV_HDR_STR-PROPOSED_SUBLOC sy-vline
WA_PPEPDV_HDR_STR-RECEIVING_SUBLOC sy-vline
WA_PPEPDV_HDR_STR-SUPPLY_AREA sy-vline
WA_PPEPDV_HDR_STR-CMP_PGUID sy-vline
WA_PPEPDV_HDR_STR-CMP_OTYPE sy-vline
WA_PPEPDV_HDR_STR-CMP_PVGUID sy-vline
WA_PPEPDV_HDR_STR-ACT_PGUID sy-vline
WA_PPEPDV_HDR_STR-ACT_OTYPE sy-vline
WA_PPEPDV_HDR_STR-COPTYPE sy-vline
WA_PPEPDV_HDR_STR-LOCEXT sy-vline
WA_PPEPDV_HDR_STR-CMPEXT_PD sy-vline
WA_PPEPDV_HDR_STR-CMPID_TEXT_PD sy-vline
WA_PPEPDV_HDR_STR-CMPID_TYPE_PD sy-vline
WA_PPEPDV_HDR_STR-LOCEXT_PD sy-vline
WA_PPEPDV_HDR_STR-COSTPROF_DUMMY sy-vline
WA_PPEPDV_HDR_STR-COSTPROF_EXT sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.