ABAP Select data from SAP table PPEHDR_DYNP into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP PPEHDR_DYNP table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to PPEHDR_DYNP. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the PPEHDR_DYNP table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_PPEHDR_DYNP TYPE STANDARD TABLE OF PPEHDR_DYNP,
      WA_PPEHDR_DYNP TYPE PPEHDR_DYNP,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: <PPEHDR_DYNP> TYPE PPEHDR_DYNP.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_PPEHDR_DYNP.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM PPEHDR_DYNP
  INTO TABLE IT_PPEHDR_DYNP.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM PPEHDR_DYNP
*  INTO TABLE @DATA(IT_PPEHDR_DYNP2).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_PPEHDR_DYNP INDEX 1 INTO DATA(WA_PPEHDR_DYNP2).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_PPEHDR_DYNP ASSIGNING <PPEHDR_DYNP>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
<PPEHDR_DYNP>-MARK = 1.
<PPEHDR_DYNP>-PPEGUID = 1.
<PPEHDR_DYNP>-PVGUID = 1.
<PPEHDR_DYNP>-OBJTYPE = 1.
<PPEHDR_DYNP>-OBJCNT = 1.
ENDLOOP.

LOOP AT IT_PPEHDR_DYNP INTO WA_PPEHDR_DYNP.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_PPEHDR_DYNP-PVNAME, sy-vline,
WA_PPEHDR_DYNP-CMPID, sy-vline,
WA_PPEHDR_DYNP-CMPEXT, sy-vline,
WA_PPEHDR_DYNP-PGUID, sy-vline,
WA_PPEHDR_DYNP-OTYPE, sy-vline,
WA_PPEHDR_DYNP-ALTNUM, sy-vline.
ENDLOOP. *Add any further fields from structure WA_PPEHDR_DYNP you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_PPEHDR_DYNP TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_PPEHDR_DYNP INTO WA_PPEHDR_DYNP. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.

*Conversion exit ALPHA, internal->external for field PVNAME CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_PPEHDR_DYNP-PVNAME IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_PPEHDR_DYNP-PVNAME.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field ALTNUM CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_PPEHDR_DYNP-ALTNUM IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_PPEHDR_DYNP-ALTNUM.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field CONCEPT CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_PPEHDR_DYNP-CONCEPT IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_PPEHDR_DYNP-CONCEPT.
WRITE:/ 'New Value:', ld_input.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_PPEHDR_DYNP_STR,
MARK TYPE STRING,
PPEGUID TYPE STRING,
PVGUID TYPE STRING,
OBJTYPE TYPE STRING,
OBJCNT TYPE STRING,
PVNAME TYPE STRING,
CMPID TYPE STRING,
CMPEXT TYPE STRING,
PGUID TYPE STRING,
OTYPE TYPE STRING,
ALTNUM TYPE STRING,
LOCID TYPE STRING,
LOCEXT TYPE STRING,
PPEUSE TYPE STRING,
PPENAME TYPE STRING,
PPETYPE TYPE STRING,
PDVTYPE TYPE STRING,
TEMPLATE_FLAG TYPE STRING,
CONCEPT TYPE STRING,
DATEFR TYPE STRING,
DATETO TYPE STRING,
BUTTON TYPE STRING,
VEREXT TYPE STRING,
RTO_BUTTON TYPE STRING,
RTO_STATUS TYPE STRING,END OF T_EKKO_STR. DATA: WA_PPEHDR_DYNP_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_PPEHDR_DYNP_STR-MARK sy-vline
WA_PPEHDR_DYNP_STR-PPEGUID sy-vline
WA_PPEHDR_DYNP_STR-PVGUID sy-vline
WA_PPEHDR_DYNP_STR-OBJTYPE sy-vline
WA_PPEHDR_DYNP_STR-OBJCNT sy-vline
WA_PPEHDR_DYNP_STR-PVNAME sy-vline
WA_PPEHDR_DYNP_STR-CMPID sy-vline
WA_PPEHDR_DYNP_STR-CMPEXT sy-vline
WA_PPEHDR_DYNP_STR-PGUID sy-vline
WA_PPEHDR_DYNP_STR-OTYPE sy-vline
WA_PPEHDR_DYNP_STR-ALTNUM sy-vline
WA_PPEHDR_DYNP_STR-LOCID sy-vline
WA_PPEHDR_DYNP_STR-LOCEXT sy-vline
WA_PPEHDR_DYNP_STR-PPEUSE sy-vline
WA_PPEHDR_DYNP_STR-PPENAME sy-vline
WA_PPEHDR_DYNP_STR-PPETYPE sy-vline
WA_PPEHDR_DYNP_STR-PDVTYPE sy-vline
WA_PPEHDR_DYNP_STR-TEMPLATE_FLAG sy-vline
WA_PPEHDR_DYNP_STR-CONCEPT sy-vline
WA_PPEHDR_DYNP_STR-DATEFR sy-vline
WA_PPEHDR_DYNP_STR-DATETO sy-vline
WA_PPEHDR_DYNP_STR-BUTTON sy-vline
WA_PPEHDR_DYNP_STR-VEREXT sy-vline
WA_PPEHDR_DYNP_STR-RTO_BUTTON sy-vline
WA_PPEHDR_DYNP_STR-RTO_STATUS sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.