ABAP Select data from SAP table PPE_PVCOL_EXPL into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP PPE_PVCOL_EXPL table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to PPE_PVCOL_EXPL. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the PPE_PVCOL_EXPL table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_PPE_PVCOL_EXPL TYPE STANDARD TABLE OF PPE_PVCOL_EXPL,
      WA_PPE_PVCOL_EXPL TYPE PPE_PVCOL_EXPL,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: <PPE_PVCOL_EXPL> TYPE PPE_PVCOL_EXPL.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_PPE_PVCOL_EXPL.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM PPE_PVCOL_EXPL
  INTO TABLE IT_PPE_PVCOL_EXPL.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM PPE_PVCOL_EXPL
*  INTO TABLE @DATA(IT_PPE_PVCOL_EXPL2).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_PPE_PVCOL_EXPL INDEX 1 INTO DATA(WA_PPE_PVCOL_EXPL2).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_PPE_PVCOL_EXPL ASSIGNING <PPE_PVCOL_EXPL>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
<PPE_PVCOL_EXPL>-MANDT = 1.
<PPE_PVCOL_EXPL>-PVGUID = 1.
<PPE_PVCOL_EXPL>-PVCNT = 1.
<PPE_PVCOL_EXPL>-AENNR = 1.
<PPE_PVCOL_EXPL>-DELFLG = 1.
ENDLOOP.

LOOP AT IT_PPE_PVCOL_EXPL INTO WA_PPE_PVCOL_EXPL.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_PPE_PVCOL_EXPL-CCODE, sy-vline,
WA_PPE_PVCOL_EXPL-PRIO, sy-vline,
WA_PPE_PVCOL_EXPL-KNOBJ, sy-vline,
WA_PPE_PVCOL_EXPL-CUOBJ, sy-vline,
WA_PPE_PVCOL_EXPL-STDVAR, sy-vline,
WA_PPE_PVCOL_EXPL-VALID, sy-vline.
ENDLOOP. *Add any further fields from structure WA_PPE_PVCOL_EXPL you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_PPE_PVCOL_EXPL TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_PPE_PVCOL_EXPL INTO WA_PPE_PVCOL_EXPL. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.

*Conversion exit ALPHA, internal->external for field AENNR CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_PPE_PVCOL_EXPL-AENNR IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_PPE_PVCOL_EXPL-AENNR.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field PVNAME CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_PPE_PVCOL_EXPL-PVNAME IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_PPE_PVCOL_EXPL-PVNAME.
WRITE:/ 'New Value:', ld_input.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_PPE_PVCOL_EXPL_STR,
MANDT TYPE STRING,
PVGUID TYPE STRING,
PVCNT TYPE STRING,
AENNR TYPE STRING,
DELFLG TYPE STRING,
CCODE TYPE STRING,
PRIO TYPE STRING,
KNOBJ TYPE STRING,
CUOBJ TYPE STRING,
STDVAR TYPE STRING,
VALID TYPE STRING,
DATUV TYPE STRING,
KNNUM TYPE STRING,
PVNAME TYPE STRING,
DATE_FROM TYPE STRING,
DATE_TO TYPE STRING,
T_PROPCODE TYPE STRING,
AENNRDATE TYPE STRING,END OF T_EKKO_STR. DATA: WA_PPE_PVCOL_EXPL_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_PPE_PVCOL_EXPL_STR-MANDT sy-vline
WA_PPE_PVCOL_EXPL_STR-PVGUID sy-vline
WA_PPE_PVCOL_EXPL_STR-PVCNT sy-vline
WA_PPE_PVCOL_EXPL_STR-AENNR sy-vline
WA_PPE_PVCOL_EXPL_STR-DELFLG sy-vline
WA_PPE_PVCOL_EXPL_STR-CCODE sy-vline
WA_PPE_PVCOL_EXPL_STR-PRIO sy-vline
WA_PPE_PVCOL_EXPL_STR-KNOBJ sy-vline
WA_PPE_PVCOL_EXPL_STR-CUOBJ sy-vline
WA_PPE_PVCOL_EXPL_STR-STDVAR sy-vline
WA_PPE_PVCOL_EXPL_STR-VALID sy-vline
WA_PPE_PVCOL_EXPL_STR-DATUV sy-vline
WA_PPE_PVCOL_EXPL_STR-KNNUM sy-vline
WA_PPE_PVCOL_EXPL_STR-PVNAME sy-vline
WA_PPE_PVCOL_EXPL_STR-DATE_FROM sy-vline
WA_PPE_PVCOL_EXPL_STR-DATE_TO sy-vline
WA_PPE_PVCOL_EXPL_STR-T_PROPCODE sy-vline
WA_PPE_PVCOL_EXPL_STR-AENNRDATE sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.