ABAP Select data from SAP table PPE_CPRO_CKLITEM_DYNP into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP PPE_CPRO_CKLITEM_DYNP table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to PPE_CPRO_CKLITEM_DYNP. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the PPE_CPRO_CKLITEM_DYNP table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_PPE_CPRO_CKLITEM_DYNP TYPE STANDARD TABLE OF PPE_CPRO_CKLITEM_DYNP,
      WA_PPE_CPRO_CKLITEM_DYNP TYPE PPE_CPRO_CKLITEM_DYNP,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: <PPE_CPRO_CKLITEM_DYNP> TYPE PPE_CPRO_CKLITEM_DYNP.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_PPE_CPRO_CKLITEM_DYNP.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM PPE_CPRO_CKLITEM_DYNP
  INTO TABLE IT_PPE_CPRO_CKLITEM_DYNP.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM PPE_CPRO_CKLITEM_DYNP
*  INTO TABLE @DATA(IT_PPE_CPRO_CKLITEM_DYNP2).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_PPE_CPRO_CKLITEM_DYNP INDEX 1 INTO DATA(WA_PPE_CPRO_CKLITEM_DYNP2).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_PPE_CPRO_CKLITEM_DYNP ASSIGNING <PPE_CPRO_CKLITEM_DYNP>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
<PPE_CPRO_CKLITEM_DYNP>-OBJLNK_GUID = 1.
<PPE_CPRO_CKLITEM_DYNP>-OBJLNK_TYPE = 1.
<PPE_CPRO_CKLITEM_DYNP>-CHNG_FLG = 1.
<PPE_CPRO_CKLITEM_DYNP>-CPROOBJ_TYPE = 1.
<PPE_CPRO_CKLITEM_DYNP>-CKLITEM_GUID = 1.
ENDLOOP.

LOOP AT IT_PPE_CPRO_CKLITEM_DYNP INTO WA_PPE_CPRO_CKLITEM_DYNP.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_PPE_CPRO_CKLITEM_DYNP-CKLITEM_NUMBER, sy-vline,
WA_PPE_CPRO_CKLITEM_DYNP-CKLITEM_NAME, sy-vline,
WA_PPE_CPRO_CKLITEM_DYNP-PROJECT_GUID, sy-vline,
WA_PPE_CPRO_CKLITEM_DYNP-PROJECT_NUMBER, sy-vline,
WA_PPE_CPRO_CKLITEM_DYNP-PROJECT_NAME, sy-vline,
WA_PPE_CPRO_CKLITEM_DYNP-ARCHIVE_FLAG, sy-vline.
ENDLOOP. *Add any further fields from structure WA_PPE_CPRO_CKLITEM_DYNP you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_PPE_CPRO_CKLITEM_DYNP TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_PPE_CPRO_CKLITEM_DYNP INTO WA_PPE_CPRO_CKLITEM_DYNP. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.

*Conversion exit ALPHA, internal->external for field CKLITEM_NUMBER CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_PPE_CPRO_CKLITEM_DYNP-CKLITEM_NUMBER IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_PPE_CPRO_CKLITEM_DYNP-CKLITEM_NUMBER.
WRITE:/ 'New Value:', ld_input.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_PPE_CPRO_CKLITEM_DYNP_STR,
OBJLNK_GUID TYPE STRING,
OBJLNK_TYPE TYPE STRING,
CHNG_FLG TYPE STRING,
CPROOBJ_TYPE TYPE STRING,
CKLITEM_GUID TYPE STRING,
CKLITEM_NUMBER TYPE STRING,
CKLITEM_NAME TYPE STRING,
PROJECT_GUID TYPE STRING,
PROJECT_NUMBER TYPE STRING,
PROJECT_NAME TYPE STRING,
ARCHIVE_FLAG TYPE STRING,
CREABY TYPE STRING,
CREADAT TYPE STRING,
CHNGBY TYPE STRING,
CHNGDAT TYPE STRING,
PROCESS TYPE STRING,
PROCESS_TEXT TYPE STRING,
RESPONSIBILITY TYPE STRING,
STATUS TYPE STRING,
EARLY_FINISH TYPE STRING,
LATE_FINISH TYPE STRING,
FIXED_FINISH TYPE STRING,
APPROVAL_RELEVANT TYPE STRING,
MANDATORY TYPE STRING,END OF T_EKKO_STR. DATA: WA_PPE_CPRO_CKLITEM_DYNP_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_PPE_CPRO_CKLITEM_DYNP_STR-OBJLNK_GUID sy-vline
WA_PPE_CPRO_CKLITEM_DYNP_STR-OBJLNK_TYPE sy-vline
WA_PPE_CPRO_CKLITEM_DYNP_STR-CHNG_FLG sy-vline
WA_PPE_CPRO_CKLITEM_DYNP_STR-CPROOBJ_TYPE sy-vline
WA_PPE_CPRO_CKLITEM_DYNP_STR-CKLITEM_GUID sy-vline
WA_PPE_CPRO_CKLITEM_DYNP_STR-CKLITEM_NUMBER sy-vline
WA_PPE_CPRO_CKLITEM_DYNP_STR-CKLITEM_NAME sy-vline
WA_PPE_CPRO_CKLITEM_DYNP_STR-PROJECT_GUID sy-vline
WA_PPE_CPRO_CKLITEM_DYNP_STR-PROJECT_NUMBER sy-vline
WA_PPE_CPRO_CKLITEM_DYNP_STR-PROJECT_NAME sy-vline
WA_PPE_CPRO_CKLITEM_DYNP_STR-ARCHIVE_FLAG sy-vline
WA_PPE_CPRO_CKLITEM_DYNP_STR-CREABY sy-vline
WA_PPE_CPRO_CKLITEM_DYNP_STR-CREADAT sy-vline
WA_PPE_CPRO_CKLITEM_DYNP_STR-CHNGBY sy-vline
WA_PPE_CPRO_CKLITEM_DYNP_STR-CHNGDAT sy-vline
WA_PPE_CPRO_CKLITEM_DYNP_STR-PROCESS sy-vline
WA_PPE_CPRO_CKLITEM_DYNP_STR-PROCESS_TEXT sy-vline
WA_PPE_CPRO_CKLITEM_DYNP_STR-RESPONSIBILITY sy-vline
WA_PPE_CPRO_CKLITEM_DYNP_STR-STATUS sy-vline
WA_PPE_CPRO_CKLITEM_DYNP_STR-EARLY_FINISH sy-vline
WA_PPE_CPRO_CKLITEM_DYNP_STR-LATE_FINISH sy-vline
WA_PPE_CPRO_CKLITEM_DYNP_STR-FIXED_FINISH sy-vline
WA_PPE_CPRO_CKLITEM_DYNP_STR-APPROVAL_RELEVANT sy-vline
WA_PPE_CPRO_CKLITEM_DYNP_STR-MANDATORY sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.