ABAP Select data from SAP table PPE_CIF_ACT_RELATION_APO30 into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP PPE_CIF_ACT_RELATION_APO30 table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to PPE_CIF_ACT_RELATION_APO30. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the PPE_CIF_ACT_RELATION_APO30 table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_PPE_CIF_ACT_RELATION_APO30 TYPE STANDARD TABLE OF PPE_CIF_ACT_RELATION_APO30,
      WA_PPE_CIF_ACT_RELATION_APO30 TYPE PPE_CIF_ACT_RELATION_APO30,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: <PPE_CIF_ACT_RELATION_APO30> TYPE PPE_CIF_ACT_RELATION_APO30.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_PPE_CIF_ACT_RELATION_APO30.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM PPE_CIF_ACT_RELATION_APO30
  INTO TABLE IT_PPE_CIF_ACT_RELATION_APO30.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM PPE_CIF_ACT_RELATION_APO30
*  INTO TABLE @DATA(IT_PPE_CIF_ACT_RELATION_APO302).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_PPE_CIF_ACT_RELATION_APO30 INDEX 1 INTO DATA(WA_PPE_CIF_ACT_RELATION_APO302).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_PPE_CIF_ACT_RELATION_APO30 ASSIGNING <PPE_CIF_ACT_RELATION_APO30>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
<PPE_CIF_ACT_RELATION_APO30>-RELATION_ID = 1.
<PPE_CIF_ACT_RELATION_APO30>-OBJECT_ID_START = 1.
<PPE_CIF_ACT_RELATION_APO30>-OBJECT_TYPE_START = 1.
<PPE_CIF_ACT_RELATION_APO30>-OBJECT_ID_TARGET = 1.
<PPE_CIF_ACT_RELATION_APO30>-OBJECT_TYPE_TARGET = 1.
ENDLOOP.

LOOP AT IT_PPE_CIF_ACT_RELATION_APO30 INTO WA_PPE_CIF_ACT_RELATION_APO30.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_PPE_CIF_ACT_RELATION_APO30-RELATION_TYPE, sy-vline,
WA_PPE_CIF_ACT_RELATION_APO30-APPLICATION_TYPE, sy-vline,
WA_PPE_CIF_ACT_RELATION_APO30-CONSTRAINT_TYPE, sy-vline,
WA_PPE_CIF_ACT_RELATION_APO30-SEQTIME_MIN, sy-vline,
WA_PPE_CIF_ACT_RELATION_APO30-SEQTIME_MAX, sy-vline,
WA_PPE_CIF_ACT_RELATION_APO30-TIME_UNIT, sy-vline.
ENDLOOP. *Add any further fields from structure WA_PPE_CIF_ACT_RELATION_APO30 you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_PPE_CIF_ACT_RELATION_APO30 TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_PPE_CIF_ACT_RELATION_APO30 INTO WA_PPE_CIF_ACT_RELATION_APO30. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.

*Conversion exit CUNIT, internal->external for field TIME_UNIT CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_PPE_CIF_ACT_RELATION_APO30-TIME_UNIT IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_PPE_CIF_ACT_RELATION_APO30-TIME_UNIT.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field LOG_SYSTEM CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_PPE_CIF_ACT_RELATION_APO30-LOG_SYSTEM IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_PPE_CIF_ACT_RELATION_APO30-LOG_SYSTEM.
WRITE:/ 'New Value:', ld_input.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_PPE_CIF_ACT_RELATION_APO30_STR,
RELATION_ID TYPE STRING,
OBJECT_ID_START TYPE STRING,
OBJECT_TYPE_START TYPE STRING,
OBJECT_ID_TARGET TYPE STRING,
OBJECT_TYPE_TARGET TYPE STRING,
RELATION_TYPE TYPE STRING,
APPLICATION_TYPE TYPE STRING,
CONSTRAINT_TYPE TYPE STRING,
SEQTIME_MIN TYPE STRING,
SEQTIME_MAX TYPE STRING,
TIME_UNIT TYPE STRING,
TIME_UNIT_ISO TYPE STRING,
MATCONSUMPTION_FLG TYPE STRING,
DELETE_FLG TYPE STRING,
LOG_SYSTEM TYPE STRING,END OF T_EKKO_STR. DATA: WA_PPE_CIF_ACT_RELATION_APO30_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_PPE_CIF_ACT_RELATION_APO30_STR-RELATION_ID sy-vline
WA_PPE_CIF_ACT_RELATION_APO30_STR-OBJECT_ID_START sy-vline
WA_PPE_CIF_ACT_RELATION_APO30_STR-OBJECT_TYPE_START sy-vline
WA_PPE_CIF_ACT_RELATION_APO30_STR-OBJECT_ID_TARGET sy-vline
WA_PPE_CIF_ACT_RELATION_APO30_STR-OBJECT_TYPE_TARGET sy-vline
WA_PPE_CIF_ACT_RELATION_APO30_STR-RELATION_TYPE sy-vline
WA_PPE_CIF_ACT_RELATION_APO30_STR-APPLICATION_TYPE sy-vline
WA_PPE_CIF_ACT_RELATION_APO30_STR-CONSTRAINT_TYPE sy-vline
WA_PPE_CIF_ACT_RELATION_APO30_STR-SEQTIME_MIN sy-vline
WA_PPE_CIF_ACT_RELATION_APO30_STR-SEQTIME_MAX sy-vline
WA_PPE_CIF_ACT_RELATION_APO30_STR-TIME_UNIT sy-vline
WA_PPE_CIF_ACT_RELATION_APO30_STR-TIME_UNIT_ISO sy-vline
WA_PPE_CIF_ACT_RELATION_APO30_STR-MATCONSUMPTION_FLG sy-vline
WA_PPE_CIF_ACT_RELATION_APO30_STR-DELETE_FLG sy-vline
WA_PPE_CIF_ACT_RELATION_APO30_STR-LOG_SYSTEM sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.