ABAP Select data from SAP table POC_S_PRC_IN into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP POC_S_PRC_IN table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to POC_S_PRC_IN. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the POC_S_PRC_IN table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_POC_S_PRC_IN TYPE STANDARD TABLE OF POC_S_PRC_IN,
      WA_POC_S_PRC_IN TYPE POC_S_PRC_IN,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: <POC_S_PRC_IN> TYPE POC_S_PRC_IN.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_POC_S_PRC_IN.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM POC_S_PRC_IN
  INTO TABLE IT_POC_S_PRC_IN.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM POC_S_PRC_IN
*  INTO TABLE @DATA(IT_POC_S_PRC_IN2).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_POC_S_PRC_IN INDEX 1 INTO DATA(WA_POC_S_PRC_IN2).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_POC_S_PRC_IN ASSIGNING <POC_S_PRC_IN>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
<POC_S_PRC_IN>-PROCESS_ID = 1.
<POC_S_PRC_IN>-PROCESS_TYPE_ID = 1.
<POC_S_PRC_IN>-PROCESS_VERSION = 1.
<POC_S_PRC_IN>-PROCESS_STATUS = 1.
<POC_S_PRC_IN>-PRC_SYS_STATUS = 1.
ENDLOOP.

LOOP AT IT_POC_S_PRC_IN INTO WA_POC_S_PRC_IN.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_POC_S_PRC_IN-PRC_END_DATE_TIM, sy-vline,
WA_POC_S_PRC_IN-CHANGED_AT, sy-vline,
WA_POC_S_PRC_IN-START_BO_ID, sy-vline,
WA_POC_S_PRC_IN-START_ITEM_ID, sy-vline,
WA_POC_S_PRC_IN-START_BO_TYPE, sy-vline,
WA_POC_S_PRC_IN-START_BA_ID, sy-vline.
ENDLOOP. *Add any further fields from structure WA_POC_S_PRC_IN you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_POC_S_PRC_IN TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_POC_S_PRC_IN INTO WA_POC_S_PRC_IN. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.

*Conversion exit POCTS, internal->external for field PRC_END_DATE_TIM CALL FUNCTION 'CONVERSION_EXIT_POCTS_OUTPUT' EXPORTING input = WA_POC_S_PRC_IN-PRC_END_DATE_TIM IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_POC_S_PRC_IN-PRC_END_DATE_TIM.
WRITE:/ 'New Value:', ld_input.

*Conversion exit POCTS, internal->external for field CHANGED_AT CALL FUNCTION 'CONVERSION_EXIT_POCTS_OUTPUT' EXPORTING input = WA_POC_S_PRC_IN-CHANGED_AT IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_POC_S_PRC_IN-CHANGED_AT.
WRITE:/ 'New Value:', ld_input.

*Conversion exit POCTS, internal->external for field START_DATE_TIME CALL FUNCTION 'CONVERSION_EXIT_POCTS_OUTPUT' EXPORTING input = WA_POC_S_PRC_IN-START_DATE_TIME IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_POC_S_PRC_IN-START_DATE_TIME.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field START_SRC_LOGSYS CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_POC_S_PRC_IN-START_SRC_LOGSYS IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_POC_S_PRC_IN-START_SRC_LOGSYS.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field LOG_SYS_ID CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_POC_S_PRC_IN-LOG_SYS_ID IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_POC_S_PRC_IN-LOG_SYS_ID.
WRITE:/ 'New Value:', ld_input.

*Conversion exit POCTS, internal->external for field END_DATE_TIME CALL FUNCTION 'CONVERSION_EXIT_POCTS_OUTPUT' EXPORTING input = WA_POC_S_PRC_IN-END_DATE_TIME IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_POC_S_PRC_IN-END_DATE_TIME.
WRITE:/ 'New Value:', ld_input.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_POC_S_PRC_IN_STR,
PROCESS_ID TYPE STRING,
PROCESS_TYPE_ID TYPE STRING,
PROCESS_VERSION TYPE STRING,
PROCESS_STATUS TYPE STRING,
PRC_SYS_STATUS TYPE STRING,
PRC_END_DATE_TIM TYPE STRING,
CHANGED_AT TYPE STRING,
START_BO_ID TYPE STRING,
START_ITEM_ID TYPE STRING,
START_BO_TYPE TYPE STRING,
START_BA_ID TYPE STRING,
START_BA_TYPE TYPE STRING,
START_DATE_TIME TYPE STRING,
PROCESS_START TYPE STRING,
UNAME TYPE STRING,
START_SRC_LOGSYS TYPE STRING,
THR_NOTIF_TIME TYPE STRING,
LOG_SYS_ID TYPE STRING,
TIME_ZONE TYPE STRING,
END_DATE_TIME TYPE STRING,END OF T_EKKO_STR. DATA: WA_POC_S_PRC_IN_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_POC_S_PRC_IN_STR-PROCESS_ID sy-vline
WA_POC_S_PRC_IN_STR-PROCESS_TYPE_ID sy-vline
WA_POC_S_PRC_IN_STR-PROCESS_VERSION sy-vline
WA_POC_S_PRC_IN_STR-PROCESS_STATUS sy-vline
WA_POC_S_PRC_IN_STR-PRC_SYS_STATUS sy-vline
WA_POC_S_PRC_IN_STR-PRC_END_DATE_TIM sy-vline
WA_POC_S_PRC_IN_STR-CHANGED_AT sy-vline
WA_POC_S_PRC_IN_STR-START_BO_ID sy-vline
WA_POC_S_PRC_IN_STR-START_ITEM_ID sy-vline
WA_POC_S_PRC_IN_STR-START_BO_TYPE sy-vline
WA_POC_S_PRC_IN_STR-START_BA_ID sy-vline
WA_POC_S_PRC_IN_STR-START_BA_TYPE sy-vline
WA_POC_S_PRC_IN_STR-START_DATE_TIME sy-vline
WA_POC_S_PRC_IN_STR-PROCESS_START sy-vline
WA_POC_S_PRC_IN_STR-UNAME sy-vline
WA_POC_S_PRC_IN_STR-START_SRC_LOGSYS sy-vline
WA_POC_S_PRC_IN_STR-THR_NOTIF_TIME sy-vline
WA_POC_S_PRC_IN_STR-LOG_SYS_ID sy-vline
WA_POC_S_PRC_IN_STR-TIME_ZONE sy-vline
WA_POC_S_PRC_IN_STR-END_DATE_TIME sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.