ABAP Select data from SAP table PNWTYV_D into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP PNWTYV_D table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to PNWTYV_D. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the PNWTYV_D table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_PNWTYV_D TYPE STANDARD TABLE OF PNWTYV_D,
      WA_PNWTYV_D TYPE PNWTYV_D,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: <PNWTYV_D> TYPE PNWTYV_D.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_PNWTYV_D.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM PNWTYV_D
  INTO TABLE IT_PNWTYV_D.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM PNWTYV_D
*  INTO TABLE @DATA(IT_PNWTYV_D2).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_PNWTYV_D INDEX 1 INTO DATA(WA_PNWTYV_D2).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_PNWTYV_D ASSIGNING <PNWTYV_D>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
<PNWTYV_D>-MANDT = 1.
<PNWTYV_D>-WRNTYVERSIONUUID = 1.
<PNWTYV_D>-WRNTYCLAIMHEADERUUID = 1.
<PNWTYV_D>-WRNTYVERSIONNUMBER = 1.
<PNWTYV_D>-WRNTYCLAIMCATEGORY = 1.
ENDLOOP.

LOOP AT IT_PNWTYV_D INTO WA_PNWTYV_D.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_PNWTYV_D-WRNTYDECISIONCODE, sy-vline,
WA_PNWTYV_D-WRNTYPARTNUMBER, sy-vline,
WA_PNWTYV_D-WRNTYPARTROLE, sy-vline,
WA_PNWTYV_D-WRNTYACTIVEVERSION, sy-vline,
WA_PNWTYV_D-WRNTYBILLINGDOCUMENTDATE, sy-vline,
WA_PNWTYV_D-WRNTYDOCUMENTCONDITION, sy-vline.
ENDLOOP. *Add any further fields from structure WA_PNWTYV_D you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_PNWTYV_D TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_PNWTYV_D INTO WA_PNWTYV_D. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.

*Conversion exit ALPHA, internal->external for field WRNTYPARTNUMBER CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_PNWTYV_D-WRNTYPARTNUMBER IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_PNWTYV_D-WRNTYPARTNUMBER.
WRITE:/ 'New Value:', ld_input.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_PNWTYV_D_STR,
MANDT TYPE STRING,
WRNTYVERSIONUUID TYPE STRING,
WRNTYCLAIMHEADERUUID TYPE STRING,
WRNTYVERSIONNUMBER TYPE STRING,
WRNTYCLAIMCATEGORY TYPE STRING,
WRNTYDECISIONCODE TYPE STRING,
WRNTYPARTNUMBER TYPE STRING,
WRNTYPARTROLE TYPE STRING,
WRNTYACTIVEVERSION TYPE STRING,
WRNTYBILLINGDOCUMENTDATE TYPE STRING,
WRNTYDOCUMENTCONDITION TYPE STRING,
WRNTYCURRENCYCODE TYPE STRING,
WRNTYPRICEEXCHANGERATEDATE TYPE STRING,
WRNTYEXCHANGERATEFORPRICE TYPE STRING,
WRNTYNUMBERPRECEDINGVERSION TYPE STRING,
SALESORGANIZATION TYPE STRING,
DISTRIBUTIONCHANNEL TYPE STRING,
DIVISION TYPE STRING,
WRNTYVERSIONFORREVERSEPOSTING TYPE STRING,
PURCHASINGORGANIZATION TYPE STRING,
WRNTYRESULTOBJCHECKCUSTOMER TYPE STRING,
WRNTYSUPPLIERCHECKRESULT TYPE STRING,
WRNTYPRICINGSTATUS TYPE STRING,
WRNTYRELVERSIONSHIPPARTNER TYPE STRING,
VALIDTODATETIME TYPE STRING,
WRNTYCLAIMCREATIONDATE TYPE STRING,
CREATEDBYUSER TYPE STRING,
WRNTYCLAIMCHANGEDDATE TYPE STRING,
LASTCHANGEDBYUSER TYPE STRING,
WRNTYOFVERSIONTEXT TYPE STRING,
DRAFTENTITYCREATIONDATETIME TYPE STRING,
DRAFTENTITYLASTCHANGEDATETIME TYPE STRING,
DRAFTADMINISTRATIVEDATAUUID TYPE STRING,
DRAFTENTITYOPERATIONCODE TYPE STRING,
HASACTIVEENTITY TYPE STRING,
DRAFTFIELDCHANGES TYPE STRING,END OF T_EKKO_STR. DATA: WA_PNWTYV_D_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_PNWTYV_D_STR-MANDT sy-vline
WA_PNWTYV_D_STR-WRNTYVERSIONUUID sy-vline
WA_PNWTYV_D_STR-WRNTYCLAIMHEADERUUID sy-vline
WA_PNWTYV_D_STR-WRNTYVERSIONNUMBER sy-vline
WA_PNWTYV_D_STR-WRNTYCLAIMCATEGORY sy-vline
WA_PNWTYV_D_STR-WRNTYDECISIONCODE sy-vline
WA_PNWTYV_D_STR-WRNTYPARTNUMBER sy-vline
WA_PNWTYV_D_STR-WRNTYPARTROLE sy-vline
WA_PNWTYV_D_STR-WRNTYACTIVEVERSION sy-vline
WA_PNWTYV_D_STR-WRNTYBILLINGDOCUMENTDATE sy-vline
WA_PNWTYV_D_STR-WRNTYDOCUMENTCONDITION sy-vline
WA_PNWTYV_D_STR-WRNTYCURRENCYCODE sy-vline
WA_PNWTYV_D_STR-WRNTYPRICEEXCHANGERATEDATE sy-vline
WA_PNWTYV_D_STR-WRNTYEXCHANGERATEFORPRICE sy-vline
WA_PNWTYV_D_STR-WRNTYNUMBERPRECEDINGVERSION sy-vline
WA_PNWTYV_D_STR-SALESORGANIZATION sy-vline
WA_PNWTYV_D_STR-DISTRIBUTIONCHANNEL sy-vline
WA_PNWTYV_D_STR-DIVISION sy-vline
WA_PNWTYV_D_STR-WRNTYVERSIONFORREVERSEPOSTING sy-vline
WA_PNWTYV_D_STR-PURCHASINGORGANIZATION sy-vline
WA_PNWTYV_D_STR-WRNTYRESULTOBJCHECKCUSTOMER sy-vline
WA_PNWTYV_D_STR-WRNTYSUPPLIERCHECKRESULT sy-vline
WA_PNWTYV_D_STR-WRNTYPRICINGSTATUS sy-vline
WA_PNWTYV_D_STR-WRNTYRELVERSIONSHIPPARTNER sy-vline
WA_PNWTYV_D_STR-VALIDTODATETIME sy-vline
WA_PNWTYV_D_STR-WRNTYCLAIMCREATIONDATE sy-vline
WA_PNWTYV_D_STR-CREATEDBYUSER sy-vline
WA_PNWTYV_D_STR-WRNTYCLAIMCHANGEDDATE sy-vline
WA_PNWTYV_D_STR-LASTCHANGEDBYUSER sy-vline
WA_PNWTYV_D_STR-WRNTYOFVERSIONTEXT sy-vline
WA_PNWTYV_D_STR-DRAFTENTITYCREATIONDATETIME sy-vline
WA_PNWTYV_D_STR-DRAFTENTITYLASTCHANGEDATETIME sy-vline
WA_PNWTYV_D_STR-DRAFTADMINISTRATIVEDATAUUID sy-vline
WA_PNWTYV_D_STR-DRAFTENTITYOPERATIONCODE sy-vline
WA_PNWTYV_D_STR-HASACTIVEENTITY sy-vline
WA_PNWTYV_D_STR-DRAFTFIELDCHANGES sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.