ABAP Select data from SAP table PNWTYH_RCLOBJ_V into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP PNWTYH_RCLOBJ_V table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to PNWTYH_RCLOBJ_V. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the PNWTYH_RCLOBJ_V table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_PNWTYH_RCLOBJ_V TYPE STANDARD TABLE OF PNWTYH_RCLOBJ_V,
      WA_PNWTYH_RCLOBJ_V TYPE PNWTYH_RCLOBJ_V,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: <PNWTYH_RCLOBJ_V> TYPE PNWTYH_RCLOBJ_V.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_PNWTYH_RCLOBJ_V.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM PNWTYH_RCLOBJ_V
  INTO TABLE IT_PNWTYH_RCLOBJ_V.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM PNWTYH_RCLOBJ_V
*  INTO TABLE @DATA(IT_PNWTYH_RCLOBJ_V2).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_PNWTYH_RCLOBJ_V INDEX 1 INTO DATA(WA_PNWTYH_RCLOBJ_V2).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_PNWTYH_RCLOBJ_V ASSIGNING <PNWTYH_RCLOBJ_V>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
<PNWTYH_RCLOBJ_V>-MANDT = 1.
<PNWTYH_RCLOBJ_V>-PNGUID_RCL = 1.
<PNWTYH_RCLOBJ_V>-ID = 1.
<PNWTYH_RCLOBJ_V>-RCLOBJ_TYPE = 1.
<PNWTYH_RCLOBJ_V>-RCLOBJ_SUBTYPE = 1.
ENDLOOP.

LOOP AT IT_PNWTYH_RCLOBJ_V INTO WA_PNWTYH_RCLOBJ_V.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_PNWTYH_RCLOBJ_V-RCLOBJ_SIGN, sy-vline,
WA_PNWTYH_RCLOBJ_V-RCLOBJ_OPTION, sy-vline,
WA_PNWTYH_RCLOBJ_V-RCLOBJ_LOW, sy-vline,
WA_PNWTYH_RCLOBJ_V-RCLOBJ_HIGH, sy-vline,
WA_PNWTYH_RCLOBJ_V-CLMNO, sy-vline,
WA_PNWTYH_RCLOBJ_V-CLMTY, sy-vline.
ENDLOOP. *Add any further fields from structure WA_PNWTYH_RCLOBJ_V you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_PNWTYH_RCLOBJ_V TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_PNWTYH_RCLOBJ_V INTO WA_PNWTYH_RCLOBJ_V. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.

*Conversion exit ALPHA, internal->external for field CLMNO CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_PNWTYH_RCLOBJ_V-CLMNO IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_PNWTYH_RCLOBJ_V-CLMNO.
WRITE:/ 'New Value:', ld_input.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_PNWTYH_RCLOBJ_V_STR,
MANDT TYPE STRING,
PNGUID_RCL TYPE STRING,
ID TYPE STRING,
RCLOBJ_TYPE TYPE STRING,
RCLOBJ_SUBTYPE TYPE STRING,
RCLOBJ_SIGN TYPE STRING,
RCLOBJ_OPTION TYPE STRING,
RCLOBJ_LOW TYPE STRING,
RCLOBJ_HIGH TYPE STRING,
CLMNO TYPE STRING,
CLMTY TYPE STRING,
REFNO TYPE STRING,
CREADAT TYPE STRING,
CREABY TYPE STRING,
EQUNR_LOW_FORMATTED TYPE STRING,
EQUNR_HIGH_FORMATTED TYPE STRING,END OF T_EKKO_STR. DATA: WA_PNWTYH_RCLOBJ_V_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_PNWTYH_RCLOBJ_V_STR-MANDT sy-vline
WA_PNWTYH_RCLOBJ_V_STR-PNGUID_RCL sy-vline
WA_PNWTYH_RCLOBJ_V_STR-ID sy-vline
WA_PNWTYH_RCLOBJ_V_STR-RCLOBJ_TYPE sy-vline
WA_PNWTYH_RCLOBJ_V_STR-RCLOBJ_SUBTYPE sy-vline
WA_PNWTYH_RCLOBJ_V_STR-RCLOBJ_SIGN sy-vline
WA_PNWTYH_RCLOBJ_V_STR-RCLOBJ_OPTION sy-vline
WA_PNWTYH_RCLOBJ_V_STR-RCLOBJ_LOW sy-vline
WA_PNWTYH_RCLOBJ_V_STR-RCLOBJ_HIGH sy-vline
WA_PNWTYH_RCLOBJ_V_STR-CLMNO sy-vline
WA_PNWTYH_RCLOBJ_V_STR-CLMTY sy-vline
WA_PNWTYH_RCLOBJ_V_STR-REFNO sy-vline
WA_PNWTYH_RCLOBJ_V_STR-CREADAT sy-vline
WA_PNWTYH_RCLOBJ_V_STR-CREABY sy-vline
WA_PNWTYH_RCLOBJ_V_STR-EQUNR_LOW_FORMATTED sy-vline
WA_PNWTYH_RCLOBJ_V_STR-EQUNR_HIGH_FORMATTED sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.