ABAP Select data from SAP table PNOSAFTGLBAL2 into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP PNOSAFTGLBAL2 table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to PNOSAFTGLBAL2. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the PNOSAFTGLBAL2 table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_PNOSAFTGLBAL2 TYPE STANDARD TABLE OF PNOSAFTGLBAL2,
      WA_PNOSAFTGLBAL2 TYPE PNOSAFTGLBAL2,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: <PNOSAFTGLBAL2> TYPE PNOSAFTGLBAL2.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_PNOSAFTGLBAL2.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM PNOSAFTGLBAL2
  INTO TABLE IT_PNOSAFTGLBAL2.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM PNOSAFTGLBAL2
*  INTO TABLE @DATA(IT_PNOSAFTGLBAL22).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_PNOSAFTGLBAL2 INDEX 1 INTO DATA(WA_PNOSAFTGLBAL22).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_PNOSAFTGLBAL2 ASSIGNING <PNOSAFTGLBAL2>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
<PNOSAFTGLBAL2>-MANDT = 1.
<PNOSAFTGLBAL2>-LEDGER = 1.
<PNOSAFTGLBAL2>-COMPANYCODE = 1.
<PNOSAFTGLBAL2>-CUSTOMER = 1.
<PNOSAFTGLBAL2>-SUPPLIER = 1.
ENDLOOP.

LOOP AT IT_PNOSAFTGLBAL2 INTO WA_PNOSAFTGLBAL2.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_PNOSAFTGLBAL2-COMPANYCODECURRENCY, sy-vline,
WA_PNOSAFTGLBAL2-STARTINGBALANCEAMTINCOCODECRCY, sy-vline,
WA_PNOSAFTGLBAL2-DEBITAMOUNTINCOCODECRCY, sy-vline,
WA_PNOSAFTGLBAL2-CREDITAMOUNTINCOCODECRCY, sy-vline,
WA_PNOSAFTGLBAL2-ENDINGBALANCEAMTINCOCODECRCY, sy-vline,
ENDLOOP. *Add any further fields from structure WA_PNOSAFTGLBAL2 you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_PNOSAFTGLBAL2 TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_PNOSAFTGLBAL2 INTO WA_PNOSAFTGLBAL2. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.

*Conversion exit ALPHA, internal->external for field LEDGER CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_PNOSAFTGLBAL2-LEDGER IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_PNOSAFTGLBAL2-LEDGER.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field CUSTOMER CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_PNOSAFTGLBAL2-CUSTOMER IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_PNOSAFTGLBAL2-CUSTOMER.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field SUPPLIER CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_PNOSAFTGLBAL2-SUPPLIER IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_PNOSAFTGLBAL2-SUPPLIER.
WRITE:/ 'New Value:', ld_input.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_PNOSAFTGLBAL2_STR,
MANDT TYPE STRING,
LEDGER TYPE STRING,
COMPANYCODE TYPE STRING,
CUSTOMER TYPE STRING,
SUPPLIER TYPE STRING,
COMPANYCODECURRENCY TYPE STRING,
STARTINGBALANCEAMTINCOCODECRCY TYPE STRING,
DEBITAMOUNTINCOCODECRCY TYPE STRING,
CREDITAMOUNTINCOCODECRCY TYPE STRING,
ENDINGBALANCEAMTINCOCODECRCY TYPE STRING,END OF T_EKKO_STR. DATA: WA_PNOSAFTGLBAL2_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_PNOSAFTGLBAL2_STR-MANDT sy-vline
WA_PNOSAFTGLBAL2_STR-LEDGER sy-vline
WA_PNOSAFTGLBAL2_STR-COMPANYCODE sy-vline
WA_PNOSAFTGLBAL2_STR-CUSTOMER sy-vline
WA_PNOSAFTGLBAL2_STR-SUPPLIER sy-vline
WA_PNOSAFTGLBAL2_STR-COMPANYCODECURRENCY sy-vline
WA_PNOSAFTGLBAL2_STR-STARTINGBALANCEAMTINCOCODECRCY sy-vline
WA_PNOSAFTGLBAL2_STR-DEBITAMOUNTINCOCODECRCY sy-vline
WA_PNOSAFTGLBAL2_STR-CREDITAMOUNTINCOCODECRCY sy-vline
WA_PNOSAFTGLBAL2_STR-ENDINGBALANCEAMTINCOCODECRCY sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.