ABAP Select data from SAP table PMPEEXECHISTOP into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP PMPEEXECHISTOP table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to PMPEEXECHISTOP. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the PMPEEXECHISTOP table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_PMPEEXECHISTOP TYPE STANDARD TABLE OF PMPEEXECHISTOP,
      WA_PMPEEXECHISTOP TYPE PMPEEXECHISTOP,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: <PMPEEXECHISTOP> TYPE PMPEEXECHISTOP.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_PMPEEXECHISTOP.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM PMPEEXECHISTOP
  INTO TABLE IT_PMPEEXECHISTOP.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM PMPEEXECHISTOP
*  INTO TABLE @DATA(IT_PMPEEXECHISTOP2).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_PMPEEXECHISTOP INDEX 1 INTO DATA(WA_PMPEEXECHISTOP2).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_PMPEEXECHISTOP ASSIGNING <PMPEEXECHISTOP>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
<PMPEEXECHISTOP>-MANDT = 1.
<PMPEEXECHISTOP>-MFGEXECDOCUMENTCATEGORY = 1.
<PMPEEXECHISTOP>-MANUFACTURINGEXECUTIONDOCUMENT = 1.
<PMPEEXECHISTOP>-MFGEXECUTIONDOCUMENTITEM = 1.
<PMPEEXECHISTOP>-MFGPROCGEXECACTION = 1.
ENDLOOP.

LOOP AT IT_PMPEEXECHISTOP INTO WA_PMPEEXECHISTOP.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_PMPEEXECHISTOP-MANUFACTURINGORDER, sy-vline,
WA_PMPEEXECHISTOP-MFGBUYOFFACTION, sy-vline,
WA_PMPEEXECHISTOP-MFGOBJECTLOGEVENTTYPE, sy-vline,
WA_PMPEEXECHISTOP-EVENTDATETIME, sy-vline,
WA_PMPEEXECHISTOP-SHOPFLOOREXECUTIONUSER, sy-vline,
WA_PMPEEXECHISTOP-CREATEDBYUSER, sy-vline.
ENDLOOP. *Add any further fields from structure WA_PMPEEXECHISTOP you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_PMPEEXECHISTOP TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_PMPEEXECHISTOP INTO WA_PMPEEXECHISTOP. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.

*Conversion exit ALPHA, internal->external for field MANUFACTURINGORDER CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_PMPEEXECHISTOP-MANUFACTURINGORDER IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_PMPEEXECHISTOP-MANUFACTURINGORDER.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field MANUFACTURINGORDERSEQUENCE CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_PMPEEXECHISTOP-MANUFACTURINGORDERSEQUENCE IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_PMPEEXECHISTOP-MANUFACTURINGORDERSEQUENCE.
WRITE:/ 'New Value:', ld_input.

*Conversion exit NUMCV, internal->external for field MANUFACTURINGORDEROPERATION CALL FUNCTION 'CONVERSION_EXIT_NUMCV_OUTPUT' EXPORTING input = WA_PMPEEXECHISTOP-MANUFACTURINGORDEROPERATION IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_PMPEEXECHISTOP-MANUFACTURINGORDEROPERATION.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field OPACTYNTWKELEMENTEXTERNALID CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_PMPEEXECHISTOP-OPACTYNTWKELEMENTEXTERNALID IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_PMPEEXECHISTOP-OPACTYNTWKELEMENTEXTERNALID.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field NOTIFICATION CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_PMPEEXECHISTOP-NOTIFICATION IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_PMPEEXECHISTOP-NOTIFICATION.
WRITE:/ 'New Value:', ld_input.

*Conversion exit MATN1, internal->external for field MATERIALCOMPONENT CALL FUNCTION 'CONVERSION_EXIT_MATN1_OUTPUT' EXPORTING input = WA_PMPEEXECHISTOP-MATERIALCOMPONENT IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_PMPEEXECHISTOP-MATERIALCOMPONENT.
WRITE:/ 'New Value:', ld_input.

*Conversion exit GERNR, internal->external for field ASSEMBLEDSERIALNUMBER CALL FUNCTION 'CONVERSION_EXIT_GERNR_OUTPUT' EXPORTING input = WA_PMPEEXECHISTOP-ASSEMBLEDSERIALNUMBER IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_PMPEEXECHISTOP-ASSEMBLEDSERIALNUMBER.
WRITE:/ 'New Value:', ld_input.

*Conversion exit CUNIT, internal->external for field PRODUCTIONUNIT CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_PMPEEXECHISTOP-PRODUCTIONUNIT IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_PMPEEXECHISTOP-PRODUCTIONUNIT.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field EQUIPMENT CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_PMPEEXECHISTOP-EQUIPMENT IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_PMPEEXECHISTOP-EQUIPMENT.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field DEFECT CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_PMPEEXECHISTOP-DEFECT IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_PMPEEXECHISTOP-DEFECT.
WRITE:/ 'New Value:', ld_input.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_PMPEEXECHISTOP_STR,
MANDT TYPE STRING,
MFGEXECDOCUMENTCATEGORY TYPE STRING,
MANUFACTURINGEXECUTIONDOCUMENT TYPE STRING,
MFGEXECUTIONDOCUMENTITEM TYPE STRING,
MFGPROCGEXECACTION TYPE STRING,
MANUFACTURINGORDER TYPE STRING,
MFGBUYOFFACTION TYPE STRING,
MFGOBJECTLOGEVENTTYPE TYPE STRING,
EVENTDATETIME TYPE STRING,
SHOPFLOOREXECUTIONUSER TYPE STRING,
CREATEDBYUSER TYPE STRING,
CREATIONDATETIME TYPE STRING,
SORTFIELD TYPE STRING,
ORDERINTERNALID TYPE STRING,
ORDEROPERATIONINTERNALID TYPE STRING,
MANUFACTURINGORDERSEQUENCE TYPE STRING,
MANUFACTURINGORDEROPERATION TYPE STRING,
MFGORDEROPERATIONTEXT TYPE STRING,
WORKCENTERINTERNALID TYPE STRING,
WORKCENTERTYPECODE TYPE STRING,
WORKCENTERPLANT TYPE STRING,
SHOPFLOORITEM TYPE STRING,
OPACTYNTWKINSTANCE TYPE STRING,
OPACTYNTWKELEMENT TYPE STRING,
OPACTYNTWKSEGMENTTYPE TYPE STRING,
OPERATIONACTIVITYNETWORK TYPE STRING,
OPACTYNTWKVERSIONCOUNTER TYPE STRING,
OPACTYNTWKELEMENTEXTERNALID TYPE STRING,
OPERATIONACTIVITY TYPE STRING,
OPERATIONACTYVERSIONCOUNTER TYPE STRING,
STATUSANDACTIONSCHEMA TYPE STRING,
DEFECTINTERNALID TYPE STRING,
NOTIFICATION TYPE STRING,
NOTIFICATIONITEM TYPE STRING,
MATERIALCOMPONENT TYPE STRING,
ASSEMBLEDSHOPFLOORITEM TYPE STRING,
ASSEMBLEDSERIALNUMBER TYPE STRING,
ASSEMBLEDMFRSERIALNUMBER TYPE STRING,
ASSEMBLEDBATCH TYPE STRING,
REFERENCEDESIGNATORVALUE TYPE STRING,
STORAGELOCATION TYPE STRING,
INVENTORYUSABILITYCODE TYPE STRING,
COMPDISASSEMBLYPERMANENCE TYPE STRING,
MATERIALCOMPONENTHASRELTDCOMP TYPE STRING,
MFGBUYOFFINTERNALID TYPE STRING,
MFGBUYOFFREFERENCEDSTEP TYPE STRING,
MFGBUYOFFADHOCSTEPDESCRIPTION TYPE STRING,
MFGBUYOFFCYCLE TYPE STRING,
RESPYMGMTTEAMID TYPE STRING,
RESPYMGMTFUNCTION TYPE STRING,
BUSINESSPROCESSCONFIRMEDQTY TYPE STRING,
PRODUCTIONUNIT TYPE STRING,
OPACTYACTUALDURNINSECONDS TYPE STRING,
POSTINGISRETROACTIVE TYPE STRING,
MFGACTIONREASONCODEGROUPCTLG TYPE STRING,
MFGACTIONREASONCODEGROUP TYPE STRING,
MANUFACTURINGACTIONREASONCODE TYPE STRING,
MFGEXECUTIONDOCUMENTNOTE TYPE STRING,
EQUIPMENT TYPE STRING,
SYSTEMMESSAGENUMBER TYPE STRING,
SYSTEMMESSAGEIDENTIFICATION TYPE STRING,
MFGEXECHISTMSGVARBLFIELD1 TYPE STRING,
MFGEXECHISTMSGVARBLFIELD2 TYPE STRING,
MFGEXECHISTMSGVARBLFIELD3 TYPE STRING,
MFGEXECHISTMSGVARBLFIELD4 TYPE STRING,
DEFECT TYPE STRING,END OF T_EKKO_STR. DATA: WA_PMPEEXECHISTOP_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_PMPEEXECHISTOP_STR-MANDT sy-vline
WA_PMPEEXECHISTOP_STR-MFGEXECDOCUMENTCATEGORY sy-vline
WA_PMPEEXECHISTOP_STR-MANUFACTURINGEXECUTIONDOCUMENT sy-vline
WA_PMPEEXECHISTOP_STR-MFGEXECUTIONDOCUMENTITEM sy-vline
WA_PMPEEXECHISTOP_STR-MFGPROCGEXECACTION sy-vline
WA_PMPEEXECHISTOP_STR-MANUFACTURINGORDER sy-vline
WA_PMPEEXECHISTOP_STR-MFGBUYOFFACTION sy-vline
WA_PMPEEXECHISTOP_STR-MFGOBJECTLOGEVENTTYPE sy-vline
WA_PMPEEXECHISTOP_STR-EVENTDATETIME sy-vline
WA_PMPEEXECHISTOP_STR-SHOPFLOOREXECUTIONUSER sy-vline
WA_PMPEEXECHISTOP_STR-CREATEDBYUSER sy-vline
WA_PMPEEXECHISTOP_STR-CREATIONDATETIME sy-vline
WA_PMPEEXECHISTOP_STR-SORTFIELD sy-vline
WA_PMPEEXECHISTOP_STR-ORDERINTERNALID sy-vline
WA_PMPEEXECHISTOP_STR-ORDEROPERATIONINTERNALID sy-vline
WA_PMPEEXECHISTOP_STR-MANUFACTURINGORDERSEQUENCE sy-vline
WA_PMPEEXECHISTOP_STR-MANUFACTURINGORDEROPERATION sy-vline
WA_PMPEEXECHISTOP_STR-MFGORDEROPERATIONTEXT sy-vline
WA_PMPEEXECHISTOP_STR-WORKCENTERINTERNALID sy-vline
WA_PMPEEXECHISTOP_STR-WORKCENTERTYPECODE sy-vline
WA_PMPEEXECHISTOP_STR-WORKCENTERPLANT sy-vline
WA_PMPEEXECHISTOP_STR-SHOPFLOORITEM sy-vline
WA_PMPEEXECHISTOP_STR-OPACTYNTWKINSTANCE sy-vline
WA_PMPEEXECHISTOP_STR-OPACTYNTWKELEMENT sy-vline
WA_PMPEEXECHISTOP_STR-OPACTYNTWKSEGMENTTYPE sy-vline
WA_PMPEEXECHISTOP_STR-OPERATIONACTIVITYNETWORK sy-vline
WA_PMPEEXECHISTOP_STR-OPACTYNTWKVERSIONCOUNTER sy-vline
WA_PMPEEXECHISTOP_STR-OPACTYNTWKELEMENTEXTERNALID sy-vline
WA_PMPEEXECHISTOP_STR-OPERATIONACTIVITY sy-vline
WA_PMPEEXECHISTOP_STR-OPERATIONACTYVERSIONCOUNTER sy-vline
WA_PMPEEXECHISTOP_STR-STATUSANDACTIONSCHEMA sy-vline
WA_PMPEEXECHISTOP_STR-DEFECTINTERNALID sy-vline
WA_PMPEEXECHISTOP_STR-NOTIFICATION sy-vline
WA_PMPEEXECHISTOP_STR-NOTIFICATIONITEM sy-vline
WA_PMPEEXECHISTOP_STR-MATERIALCOMPONENT sy-vline
WA_PMPEEXECHISTOP_STR-ASSEMBLEDSHOPFLOORITEM sy-vline
WA_PMPEEXECHISTOP_STR-ASSEMBLEDSERIALNUMBER sy-vline
WA_PMPEEXECHISTOP_STR-ASSEMBLEDMFRSERIALNUMBER sy-vline
WA_PMPEEXECHISTOP_STR-ASSEMBLEDBATCH sy-vline
WA_PMPEEXECHISTOP_STR-REFERENCEDESIGNATORVALUE sy-vline
WA_PMPEEXECHISTOP_STR-STORAGELOCATION sy-vline
WA_PMPEEXECHISTOP_STR-INVENTORYUSABILITYCODE sy-vline
WA_PMPEEXECHISTOP_STR-COMPDISASSEMBLYPERMANENCE sy-vline
WA_PMPEEXECHISTOP_STR-MATERIALCOMPONENTHASRELTDCOMP sy-vline
WA_PMPEEXECHISTOP_STR-MFGBUYOFFINTERNALID sy-vline
WA_PMPEEXECHISTOP_STR-MFGBUYOFFREFERENCEDSTEP sy-vline
WA_PMPEEXECHISTOP_STR-MFGBUYOFFADHOCSTEPDESCRIPTION sy-vline
WA_PMPEEXECHISTOP_STR-MFGBUYOFFCYCLE sy-vline
WA_PMPEEXECHISTOP_STR-RESPYMGMTTEAMID sy-vline
WA_PMPEEXECHISTOP_STR-RESPYMGMTFUNCTION sy-vline
WA_PMPEEXECHISTOP_STR-BUSINESSPROCESSCONFIRMEDQTY sy-vline
WA_PMPEEXECHISTOP_STR-PRODUCTIONUNIT sy-vline
WA_PMPEEXECHISTOP_STR-OPACTYACTUALDURNINSECONDS sy-vline
WA_PMPEEXECHISTOP_STR-POSTINGISRETROACTIVE sy-vline
WA_PMPEEXECHISTOP_STR-MFGACTIONREASONCODEGROUPCTLG sy-vline
WA_PMPEEXECHISTOP_STR-MFGACTIONREASONCODEGROUP sy-vline
WA_PMPEEXECHISTOP_STR-MANUFACTURINGACTIONREASONCODE sy-vline
WA_PMPEEXECHISTOP_STR-MFGEXECUTIONDOCUMENTNOTE sy-vline
WA_PMPEEXECHISTOP_STR-EQUIPMENT sy-vline
WA_PMPEEXECHISTOP_STR-SYSTEMMESSAGENUMBER sy-vline
WA_PMPEEXECHISTOP_STR-SYSTEMMESSAGEIDENTIFICATION sy-vline
WA_PMPEEXECHISTOP_STR-MFGEXECHISTMSGVARBLFIELD1 sy-vline
WA_PMPEEXECHISTOP_STR-MFGEXECHISTMSGVARBLFIELD2 sy-vline
WA_PMPEEXECHISTOP_STR-MFGEXECHISTMSGVARBLFIELD3 sy-vline
WA_PMPEEXECHISTOP_STR-MFGEXECHISTMSGVARBLFIELD4 sy-vline
WA_PMPEEXECHISTOP_STR-DEFECT sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.