ABAP Select data from SAP table PMPEASSRLTDINST into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP PMPEASSRLTDINST table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to PMPEASSRLTDINST. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the PMPEASSRLTDINST table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_PMPEASSRLTDINST TYPE STANDARD TABLE OF PMPEASSRLTDINST,
      WA_PMPEASSRLTDINST TYPE PMPEASSRLTDINST,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: <PMPEASSRLTDINST> TYPE PMPEASSRLTDINST.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_PMPEASSRLTDINST.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM PMPEASSRLTDINST
  INTO TABLE IT_PMPEASSRLTDINST.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM PMPEASSRLTDINST
*  INTO TABLE @DATA(IT_PMPEASSRLTDINST2).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_PMPEASSRLTDINST INDEX 1 INTO DATA(WA_PMPEASSRLTDINST2).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_PMPEASSRLTDINST ASSIGNING <PMPEASSRLTDINST>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
<PMPEASSRLTDINST>-MANDT = 1.
<PMPEASSRLTDINST>-RESERVATION = 1.
<PMPEASSRLTDINST>-RESERVATIONITEM = 1.
<PMPEASSRLTDINST>-RECORDTYPE = 1.
<PMPEASSRLTDINST>-OPACTYNTWKINSTANCE = 1.
ENDLOOP.

LOOP AT IT_PMPEASSRLTDINST INTO WA_PMPEASSRLTDINST.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_PMPEASSRLTDINST-OPACTYNTWKELEMENT, sy-vline,
WA_PMPEASSRLTDINST-ASSEMBLYSHOPFLOORITEM, sy-vline,
WA_PMPEASSRLTDINST-ORIGLDGTLMOCKUPCHARCSUUID, sy-vline,
WA_PMPEASSRLTDINST-RELTDORIGLDGTLMOCKUPCHARCSUUID, sy-vline,
WA_PMPEASSRLTDINST-MATERIAL, sy-vline,
WA_PMPEASSRLTDINST-PLANT, sy-vline.
ENDLOOP. *Add any further fields from structure WA_PMPEASSRLTDINST you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_PMPEASSRLTDINST TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_PMPEASSRLTDINST INTO WA_PMPEASSRLTDINST. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.

*Conversion exit MATN1, internal->external for field MATERIAL CALL FUNCTION 'CONVERSION_EXIT_MATN1_OUTPUT' EXPORTING input = WA_PMPEASSRLTDINST-MATERIAL IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_PMPEASSRLTDINST-MATERIAL.
WRITE:/ 'New Value:', ld_input.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_PMPEASSRLTDINST_STR,
MANDT TYPE STRING,
RESERVATION TYPE STRING,
RESERVATIONITEM TYPE STRING,
RECORDTYPE TYPE STRING,
OPACTYNTWKINSTANCE TYPE STRING,
OPACTYNTWKELEMENT TYPE STRING,
ASSEMBLYSHOPFLOORITEM TYPE STRING,
ORIGLDGTLMOCKUPCHARCSUUID TYPE STRING,
RELTDORIGLDGTLMOCKUPCHARCSUUID TYPE STRING,
MATERIAL TYPE STRING,
PLANT TYPE STRING,
REFERENCEDESIGNATORVALUE TYPE STRING,
BATCH TYPE STRING,
SHOPFLOORITEM TYPE STRING,
RELATEDRESERVATION TYPE STRING,
RELATEDRESERVATIONITEM TYPE STRING,
RELATEDRECORDTYPE TYPE STRING,
RELATEDOPACTYNTWKINSTANCE TYPE STRING,
RELATEDOPACTYNTWKELEMENT TYPE STRING,END OF T_EKKO_STR. DATA: WA_PMPEASSRLTDINST_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_PMPEASSRLTDINST_STR-MANDT sy-vline
WA_PMPEASSRLTDINST_STR-RESERVATION sy-vline
WA_PMPEASSRLTDINST_STR-RESERVATIONITEM sy-vline
WA_PMPEASSRLTDINST_STR-RECORDTYPE sy-vline
WA_PMPEASSRLTDINST_STR-OPACTYNTWKINSTANCE sy-vline
WA_PMPEASSRLTDINST_STR-OPACTYNTWKELEMENT sy-vline
WA_PMPEASSRLTDINST_STR-ASSEMBLYSHOPFLOORITEM sy-vline
WA_PMPEASSRLTDINST_STR-ORIGLDGTLMOCKUPCHARCSUUID sy-vline
WA_PMPEASSRLTDINST_STR-RELTDORIGLDGTLMOCKUPCHARCSUUID sy-vline
WA_PMPEASSRLTDINST_STR-MATERIAL sy-vline
WA_PMPEASSRLTDINST_STR-PLANT sy-vline
WA_PMPEASSRLTDINST_STR-REFERENCEDESIGNATORVALUE sy-vline
WA_PMPEASSRLTDINST_STR-BATCH sy-vline
WA_PMPEASSRLTDINST_STR-SHOPFLOORITEM sy-vline
WA_PMPEASSRLTDINST_STR-RELATEDRESERVATION sy-vline
WA_PMPEASSRLTDINST_STR-RELATEDRESERVATIONITEM sy-vline
WA_PMPEASSRLTDINST_STR-RELATEDRECORDTYPE sy-vline
WA_PMPEASSRLTDINST_STR-RELATEDOPACTYNTWKINSTANCE sy-vline
WA_PMPEASSRLTDINST_STR-RELATEDOPACTYNTWKELEMENT sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.