ABAP Select data from SAP table PMD_S_PRD_PLNT_ESPP into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP PMD_S_PRD_PLNT_ESPP table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to PMD_S_PRD_PLNT_ESPP. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the PMD_S_PRD_PLNT_ESPP table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_PMD_S_PRD_PLNT_ESPP TYPE STANDARD TABLE OF PMD_S_PRD_PLNT_ESPP,
      WA_PMD_S_PRD_PLNT_ESPP TYPE PMD_S_PRD_PLNT_ESPP,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: <PMD_S_PRD_PLNT_ESPP> TYPE PMD_S_PRD_PLNT_ESPP.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_PMD_S_PRD_PLNT_ESPP.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM PMD_S_PRD_PLNT_ESPP
  INTO TABLE IT_PMD_S_PRD_PLNT_ESPP.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM PMD_S_PRD_PLNT_ESPP
*  INTO TABLE @DATA(IT_PMD_S_PRD_PLNT_ESPP2).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_PMD_S_PRD_PLNT_ESPP INDEX 1 INTO DATA(WA_PMD_S_PRD_PLNT_ESPP2).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_PMD_S_PRD_PLNT_ESPP ASSIGNING <PMD_S_PRD_PLNT_ESPP>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
<PMD_S_PRD_PLNT_ESPP>-PRODUCT = 1.
<PMD_S_PRD_PLNT_ESPP>-PLANT = 1.
<PMD_S_PRD_PLNT_ESPP>-ESPPISUSED = 1.
<PMD_S_PRD_PLNT_ESPP>-PRODUCTALERTRELEVANCECODE = 1.
<PMD_S_PRD_PLNT_ESPP>-LOCPRODGOODSRECEIPTPROCHOURS = 1.
ENDLOOP.

LOOP AT IT_PMD_S_PRD_PLNT_ESPP INTO WA_PMD_S_PRD_PLNT_ESPP.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_PMD_S_PRD_PLNT_ESPP-LOCPRODGOODSISSUEPROCHOURS, sy-vline,
WA_PMD_S_PRD_PLNT_ESPP-PARLOCSAFETYSTOCKQUANTITY, sy-vline,
WA_PMD_S_PRD_PLNT_ESPP-REPAIRSAFETYSTOCKQUANTITY, sy-vline,
WA_PMD_S_PRD_PLNT_ESPP-VCLSAFETYSTOCKQUANTITY, sy-vline,
WA_PMD_S_PRD_PLNT_ESPP-VCLPARLOCSAFETYSTOCKQUANTITY, sy-vline,
WA_PMD_S_PRD_PLNT_ESPP-VCLREPAIRSAFETYSTOCKQUANTITY, sy-vline.
ENDLOOP. *Add any further fields from structure WA_PMD_S_PRD_PLNT_ESPP you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_PMD_S_PRD_PLNT_ESPP TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_PMD_S_PRD_PLNT_ESPP INTO WA_PMD_S_PRD_PLNT_ESPP. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.

*Conversion exit MATN1, internal->external for field PRODUCT CALL FUNCTION 'CONVERSION_EXIT_MATN1_OUTPUT' EXPORTING input = WA_PMD_S_PRD_PLNT_ESPP-PRODUCT IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_PMD_S_PRD_PLNT_ESPP-PRODUCT.
WRITE:/ 'New Value:', ld_input.

*Conversion exit TSTRG, internal->external for field LOCPRODGOODSRECEIPTPROCHOURS CALL FUNCTION 'CONVERSION_EXIT_TSTRG_OUTPUT' EXPORTING input = WA_PMD_S_PRD_PLNT_ESPP-LOCPRODGOODSRECEIPTPROCHOURS IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_PMD_S_PRD_PLNT_ESPP-LOCPRODGOODSRECEIPTPROCHOURS.
WRITE:/ 'New Value:', ld_input.

*Conversion exit TSTRG, internal->external for field LOCPRODGOODSISSUEPROCHOURS CALL FUNCTION 'CONVERSION_EXIT_TSTRG_OUTPUT' EXPORTING input = WA_PMD_S_PRD_PLNT_ESPP-LOCPRODGOODSISSUEPROCHOURS IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_PMD_S_PRD_PLNT_ESPP-LOCPRODGOODSISSUEPROCHOURS.
WRITE:/ 'New Value:', ld_input.

*Conversion exit TSTRG, internal->external for field SRVCPARTSTHROUGHPUTTIMEDURN CALL FUNCTION 'CONVERSION_EXIT_TSTRG_OUTPUT' EXPORTING input = WA_PMD_S_PRD_PLNT_ESPP-SRVCPARTSTHROUGHPUTTIMEDURN IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_PMD_S_PRD_PLNT_ESPP-SRVCPARTSTHROUGHPUTTIMEDURN.
WRITE:/ 'New Value:', ld_input.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_PMD_S_PRD_PLNT_ESPP_STR,
PRODUCT TYPE STRING,
PLANT TYPE STRING,
ESPPISUSED TYPE STRING,
PRODUCTALERTRELEVANCECODE TYPE STRING,
LOCPRODGOODSRECEIPTPROCHOURS TYPE STRING,
LOCPRODGOODSISSUEPROCHOURS TYPE STRING,
PARLOCSAFETYSTOCKQUANTITY TYPE STRING,
REPAIRSAFETYSTOCKQUANTITY TYPE STRING,
VCLSAFETYSTOCKQUANTITY TYPE STRING,
VCLPARLOCSAFETYSTOCKQUANTITY TYPE STRING,
VCLREPAIRSAFETYSTOCKQUANTITY TYPE STRING,
VCLREORDERPOINTQUANTITY TYPE STRING,
VCLMAXIMUMSTOCKQUANTITY TYPE STRING,
PRODUCTPROCUREMENTCOSTSVAL TYPE STRING,
GOODSRECEIPTHANDLINGCOST TYPE STRING,
GOODSISSUEHANDLINGCOST TYPE STRING,
COSTFACTORFORSTOCKHOLDINGVAL TYPE STRING,
THIRDPARTYORDERPROCESSING TYPE STRING,
SRVCPARTSTHROUGHPUTTIMEDURN TYPE STRING,
INIT_ATTR TYPE STRING,END OF T_EKKO_STR. DATA: WA_PMD_S_PRD_PLNT_ESPP_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_PMD_S_PRD_PLNT_ESPP_STR-PRODUCT sy-vline
WA_PMD_S_PRD_PLNT_ESPP_STR-PLANT sy-vline
WA_PMD_S_PRD_PLNT_ESPP_STR-ESPPISUSED sy-vline
WA_PMD_S_PRD_PLNT_ESPP_STR-PRODUCTALERTRELEVANCECODE sy-vline
WA_PMD_S_PRD_PLNT_ESPP_STR-LOCPRODGOODSRECEIPTPROCHOURS sy-vline
WA_PMD_S_PRD_PLNT_ESPP_STR-LOCPRODGOODSISSUEPROCHOURS sy-vline
WA_PMD_S_PRD_PLNT_ESPP_STR-PARLOCSAFETYSTOCKQUANTITY sy-vline
WA_PMD_S_PRD_PLNT_ESPP_STR-REPAIRSAFETYSTOCKQUANTITY sy-vline
WA_PMD_S_PRD_PLNT_ESPP_STR-VCLSAFETYSTOCKQUANTITY sy-vline
WA_PMD_S_PRD_PLNT_ESPP_STR-VCLPARLOCSAFETYSTOCKQUANTITY sy-vline
WA_PMD_S_PRD_PLNT_ESPP_STR-VCLREPAIRSAFETYSTOCKQUANTITY sy-vline
WA_PMD_S_PRD_PLNT_ESPP_STR-VCLREORDERPOINTQUANTITY sy-vline
WA_PMD_S_PRD_PLNT_ESPP_STR-VCLMAXIMUMSTOCKQUANTITY sy-vline
WA_PMD_S_PRD_PLNT_ESPP_STR-PRODUCTPROCUREMENTCOSTSVAL sy-vline
WA_PMD_S_PRD_PLNT_ESPP_STR-GOODSRECEIPTHANDLINGCOST sy-vline
WA_PMD_S_PRD_PLNT_ESPP_STR-GOODSISSUEHANDLINGCOST sy-vline
WA_PMD_S_PRD_PLNT_ESPP_STR-COSTFACTORFORSTOCKHOLDINGVAL sy-vline
WA_PMD_S_PRD_PLNT_ESPP_STR-THIRDPARTYORDERPROCESSING sy-vline
WA_PMD_S_PRD_PLNT_ESPP_STR-SRVCPARTSTHROUGHPUTTIMEDURN sy-vline
WA_PMD_S_PRD_PLNT_ESPP_STR-INIT_ATTR sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.