ABAP Select data from SAP table PMCO_OP into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP PMCO_OP table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to PMCO_OP. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the PMCO_OP table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_PMCO_OP TYPE STANDARD TABLE OF PMCO_OP,
      WA_PMCO_OP TYPE PMCO_OP,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: <PMCO_OP> TYPE PMCO_OP.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_PMCO_OP.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM PMCO_OP
  INTO TABLE IT_PMCO_OP.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM PMCO_OP
*  INTO TABLE @DATA(IT_PMCO_OP2).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_PMCO_OP INDEX 1 INTO DATA(WA_PMCO_OP2).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_PMCO_OP ASSIGNING <PMCO_OP>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
<PMCO_OP>-MANDT = 1.
<PMCO_OP>-OBJNR = 1.
<PMCO_OP>-COCUR = 1.
<PMCO_OP>-BELTP = 1.
<PMCO_OP>-WRTTP = 1.
ENDLOOP.

LOOP AT IT_PMCO_OP INTO WA_PMCO_OP.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_PMCO_OP-GJAHR, sy-vline,
WA_PMCO_OP-ACPOS, sy-vline,
WA_PMCO_OP-VERSN, sy-vline,
WA_PMCO_OP-PERBL, sy-vline,
WA_PMCO_OP-VORGA, sy-vline,
WA_PMCO_OP-BEMOT, sy-vline.
ENDLOOP. *Add any further fields from structure WA_PMCO_OP you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_PMCO_OP TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_PMCO_OP INTO WA_PMCO_OP. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.

*Conversion exit ALPHA, internal->external for field WRTTP CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_PMCO_OP-WRTTP IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_PMCO_OP-WRTTP.
WRITE:/ 'New Value:', ld_input.

*Conversion exit GJAHR, internal->external for field GJAHR CALL FUNCTION 'CONVERSION_EXIT_GJAHR_OUTPUT' EXPORTING input = WA_PMCO_OP-GJAHR IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_PMCO_OP-GJAHR.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field VERSN CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_PMCO_OP-VERSN IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_PMCO_OP-VERSN.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ABKAT, internal->external for field ABKAT CALL FUNCTION 'CONVERSION_EXIT_ABKAT_OUTPUT' EXPORTING input = WA_PMCO_OP-ABKAT IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_PMCO_OP-ABKAT.
WRITE:/ 'New Value:', ld_input.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_PMCO_OP_STR,
MANDT TYPE STRING,
OBJNR TYPE STRING,
COCUR TYPE STRING,
BELTP TYPE STRING,
WRTTP TYPE STRING,
GJAHR TYPE STRING,
ACPOS TYPE STRING,
VERSN TYPE STRING,
PERBL TYPE STRING,
VORGA TYPE STRING,
BEMOT TYPE STRING,
ABKAT TYPE STRING,
WRT00 TYPE STRING,
WRT01 TYPE STRING,
WRT02 TYPE STRING,
WRT03 TYPE STRING,
WRT04 TYPE STRING,
WRT05 TYPE STRING,
WRT06 TYPE STRING,
WRT07 TYPE STRING,
WRT08 TYPE STRING,
WRT09 TYPE STRING,
WRT10 TYPE STRING,
WRT11 TYPE STRING,
WRT12 TYPE STRING,
WRT13 TYPE STRING,
WRT14 TYPE STRING,
WRT15 TYPE STRING,
WRT16 TYPE STRING,END OF T_EKKO_STR. DATA: WA_PMCO_OP_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_PMCO_OP_STR-MANDT sy-vline
WA_PMCO_OP_STR-OBJNR sy-vline
WA_PMCO_OP_STR-COCUR sy-vline
WA_PMCO_OP_STR-BELTP sy-vline
WA_PMCO_OP_STR-WRTTP sy-vline
WA_PMCO_OP_STR-GJAHR sy-vline
WA_PMCO_OP_STR-ACPOS sy-vline
WA_PMCO_OP_STR-VERSN sy-vline
WA_PMCO_OP_STR-PERBL sy-vline
WA_PMCO_OP_STR-VORGA sy-vline
WA_PMCO_OP_STR-BEMOT sy-vline
WA_PMCO_OP_STR-ABKAT sy-vline
WA_PMCO_OP_STR-WRT00 sy-vline
WA_PMCO_OP_STR-WRT01 sy-vline
WA_PMCO_OP_STR-WRT02 sy-vline
WA_PMCO_OP_STR-WRT03 sy-vline
WA_PMCO_OP_STR-WRT04 sy-vline
WA_PMCO_OP_STR-WRT05 sy-vline
WA_PMCO_OP_STR-WRT06 sy-vline
WA_PMCO_OP_STR-WRT07 sy-vline
WA_PMCO_OP_STR-WRT08 sy-vline
WA_PMCO_OP_STR-WRT09 sy-vline
WA_PMCO_OP_STR-WRT10 sy-vline
WA_PMCO_OP_STR-WRT11 sy-vline
WA_PMCO_OP_STR-WRT12 sy-vline
WA_PMCO_OP_STR-WRT13 sy-vline
WA_PMCO_OP_STR-WRT14 sy-vline
WA_PMCO_OP_STR-WRT15 sy-vline
WA_PMCO_OP_STR-WRT16 sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.