ABAP Select data from SAP table PLMZD into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP PLMZD table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to PLMZD. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the PLMZD table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_PLMZD TYPE STANDARD TABLE OF PLMZD,
      WA_PLMZD TYPE PLMZD,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: <PLMZD> TYPE PLMZD.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_PLMZD.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM PLMZD
  INTO TABLE IT_PLMZD.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM PLMZD
*  INTO TABLE @DATA(IT_PLMZD2).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_PLMZD INDEX 1 INTO DATA(WA_PLMZD2).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_PLMZD ASSIGNING <PLMZD>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
<PLMZD>-MANDT = 1.
<PLMZD>-PLNTY = 1.
<PLMZD>-PLNNR = 1.
<PLMZD>-ZUONR = 1.
<PLMZD>-ZAEHL = 1.
ENDLOOP.

LOOP AT IT_PLMZD INTO WA_PLMZD.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_PLMZD-DATUV, sy-vline,
WA_PLMZD-TECHV, sy-vline,
WA_PLMZD-AENNR, sy-vline,
WA_PLMZD-LOEKZ, sy-vline,
WA_PLMZD-PARKZ, sy-vline,
WA_PLMZD-PLNAL, sy-vline.
ENDLOOP. *Add any further fields from structure WA_PLMZD you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_PLMZD TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_PLMZD INTO WA_PLMZD. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.

*Conversion exit ALPHA, internal->external for field PLNNR CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_PLMZD-PLNNR IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_PLMZD-PLNNR.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field AENNR CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_PLMZD-AENNR IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_PLMZD-AENNR.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field PLNAL CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_PLMZD-PLNAL IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_PLMZD-PLNAL.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field PLNFL CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_PLMZD-PLNFL IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_PLMZD-PLNFL.
WRITE:/ 'New Value:', ld_input.

*Conversion exit NUMCV, internal->external for field STLNR CALL FUNCTION 'CONVERSION_EXIT_NUMCV_OUTPUT' EXPORTING input = WA_PLMZD-STLNR IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_PLMZD-STLNR.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field STLAL CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_PLMZD-STLAL IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_PLMZD-STLAL.
WRITE:/ 'New Value:', ld_input.

*Conversion exit CUNIT, internal->external for field ZUMEI CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_PLMZD-ZUMEI IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_PLMZD-ZUMEI.
WRITE:/ 'New Value:', ld_input.

*Conversion exit CUNIT, internal->external for field IMEIN CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_PLMZD-IMEIN IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_PLMZD-IMEIN.
WRITE:/ 'New Value:', ld_input.

*Conversion exit MATN1, internal->external for field GP_MATNR CALL FUNCTION 'CONVERSION_EXIT_MATN1_OUTPUT' EXPORTING input = WA_PLMZD-GP_MATNR IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_PLMZD-GP_MATNR.
WRITE:/ 'New Value:', ld_input.

*Conversion exit NUMCV, internal->external for field GP_UVORN CALL FUNCTION 'CONVERSION_EXIT_NUMCV_OUTPUT' EXPORTING input = WA_PLMZD-GP_UVORN IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_PLMZD-GP_UVORN.
WRITE:/ 'New Value:', ld_input.

*Conversion exit AOBAR, internal->external for field AOBAR CALL FUNCTION 'CONVERSION_EXIT_AOBAR_OUTPUT' EXPORTING input = WA_PLMZD-AOBAR IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_PLMZD-AOBAR.
WRITE:/ 'New Value:', ld_input.

*Conversion exit CUNIT, internal->external for field ZEINH CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_PLMZD-ZEINH IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_PLMZD-ZEINH.
WRITE:/ 'New Value:', ld_input.

*Conversion exit NUMCV, internal->external for field STLNR_W CALL FUNCTION 'CONVERSION_EXIT_NUMCV_OUTPUT' EXPORTING input = WA_PLMZD-STLNR_W IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_PLMZD-STLNR_W.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field STLAL_W CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_PLMZD-STLAL_W IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_PLMZD-STLAL_W.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field VERSN CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_PLMZD-VERSN IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_PLMZD-VERSN.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field VERSN_SOURCE CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_PLMZD-VERSN_SOURCE IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_PLMZD-VERSN_SOURCE.
WRITE:/ 'New Value:', ld_input.

*Conversion exit MATN1, internal->external for field MATNR CALL FUNCTION 'CONVERSION_EXIT_MATN1_OUTPUT' EXPORTING input = WA_PLMZD-MATNR IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_PLMZD-MATNR.
WRITE:/ 'New Value:', ld_input.

*Conversion exit NUMCV, internal->external for field POSNR CALL FUNCTION 'CONVERSION_EXIT_NUMCV_OUTPUT' EXPORTING input = WA_PLMZD-POSNR IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_PLMZD-POSNR.
WRITE:/ 'New Value:', ld_input.

*Conversion exit CUNIT, internal->external for field MEINS CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_PLMZD-MEINS IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_PLMZD-MEINS.
WRITE:/ 'New Value:', ld_input.

*Conversion exit NUMCV, internal->external for field IUPOS CALL FUNCTION 'CONVERSION_EXIT_NUMCV_OUTPUT' EXPORTING input = WA_PLMZD-IUPOS IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_PLMZD-IUPOS.
WRITE:/ 'New Value:', ld_input.

*Conversion exit MATN1, internal->external for field BOMAT CALL FUNCTION 'CONVERSION_EXIT_MATN1_OUTPUT' EXPORTING input = WA_PLMZD-BOMAT IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_PLMZD-BOMAT.
WRITE:/ 'New Value:', ld_input.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_PLMZD_STR,
MANDT TYPE STRING,
PLNTY TYPE STRING,
PLNNR TYPE STRING,
ZUONR TYPE STRING,
ZAEHL TYPE STRING,
DATUV TYPE STRING,
TECHV TYPE STRING,
AENNR TYPE STRING,
LOEKZ TYPE STRING,
PARKZ TYPE STRING,
PLNAL TYPE STRING,
PLNFL TYPE STRING,
PLNKN TYPE STRING,
STLTY TYPE STRING,
STLNR TYPE STRING,
STLAL TYPE STRING,
STLKN TYPE STRING,
WERK_STL TYPE STRING,
ZUDIV TYPE STRING,
ZUMS1 TYPE STRING,
ZUMS2 TYPE STRING,
ZUMS3 TYPE STRING,
ZUMEI TYPE STRING,
IMENG TYPE STRING,
IMEIN TYPE STRING,
ANDAT TYPE STRING,
ANNAM TYPE STRING,
AEDAT TYPE STRING,
AENAM TYPE STRING,
RGEKZ TYPE STRING,
STLST TYPE STRING,
STLWG TYPE STRING,
REFKN TYPE STRING,
GP_MATNR TYPE STRING,
GP_WERKS TYPE STRING,
GP_UVORN TYPE STRING,
GP_KRIT1 TYPE STRING,
GP_FREET TYPE STRING,
AOBAR TYPE STRING,
ZEINH TYPE STRING,
DAUER TYPE STRING,
DMENG TYPE STRING,
KNTTP TYPE STRING,
FLGEX TYPE STRING,
VORAB TYPE STRING,
STRECKE TYPE STRING,
STLTY_W TYPE STRING,
STLNR_W TYPE STRING,
STLAL_W TYPE STRING,
KANTE TYPE STRING,
LGORT TYPE STRING,
DISP TYPE STRING,
PRODFLOWID TYPE STRING,
BEIKZ TYPE STRING,
ABLAD TYPE STRING,
WEMPF TYPE STRING,
VALID_TO TYPE STRING,
LOEKZ_INHERITED TYPE STRING,
VERSN TYPE STRING,
VERSN_SOURCE TYPE STRING,
VERSN_SOURCE_ZUONR TYPE STRING,
BOM_VERSN TYPE STRING,
BOM_VERSN_W TYPE STRING,
LOG_COMP TYPE STRING,
DATUB TYPE STRING,
MATNR TYPE STRING,
WERKS TYPE STRING,
MAKTX TYPE STRING,
POSNR TYPE STRING,
MENGE TYPE STRING,
MEINS TYPE STRING,
IUPOS TYPE STRING,
IEBOR TYPE STRING,
BOMAT TYPE STRING,
DBSKZ TYPE STRING,
ARBPL TYPE STRING,
DUMPS TYPE STRING,END OF T_EKKO_STR. DATA: WA_PLMZD_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_PLMZD_STR-MANDT sy-vline
WA_PLMZD_STR-PLNTY sy-vline
WA_PLMZD_STR-PLNNR sy-vline
WA_PLMZD_STR-ZUONR sy-vline
WA_PLMZD_STR-ZAEHL sy-vline
WA_PLMZD_STR-DATUV sy-vline
WA_PLMZD_STR-TECHV sy-vline
WA_PLMZD_STR-AENNR sy-vline
WA_PLMZD_STR-LOEKZ sy-vline
WA_PLMZD_STR-PARKZ sy-vline
WA_PLMZD_STR-PLNAL sy-vline
WA_PLMZD_STR-PLNFL sy-vline
WA_PLMZD_STR-PLNKN sy-vline
WA_PLMZD_STR-STLTY sy-vline
WA_PLMZD_STR-STLNR sy-vline
WA_PLMZD_STR-STLAL sy-vline
WA_PLMZD_STR-STLKN sy-vline
WA_PLMZD_STR-WERK_STL sy-vline
WA_PLMZD_STR-ZUDIV sy-vline
WA_PLMZD_STR-ZUMS1 sy-vline
WA_PLMZD_STR-ZUMS2 sy-vline
WA_PLMZD_STR-ZUMS3 sy-vline
WA_PLMZD_STR-ZUMEI sy-vline
WA_PLMZD_STR-IMENG sy-vline
WA_PLMZD_STR-IMEIN sy-vline
WA_PLMZD_STR-ANDAT sy-vline
WA_PLMZD_STR-ANNAM sy-vline
WA_PLMZD_STR-AEDAT sy-vline
WA_PLMZD_STR-AENAM sy-vline
WA_PLMZD_STR-RGEKZ sy-vline
WA_PLMZD_STR-STLST sy-vline
WA_PLMZD_STR-STLWG sy-vline
WA_PLMZD_STR-REFKN sy-vline
WA_PLMZD_STR-GP_MATNR sy-vline
WA_PLMZD_STR-GP_WERKS sy-vline
WA_PLMZD_STR-GP_UVORN sy-vline
WA_PLMZD_STR-GP_KRIT1 sy-vline
WA_PLMZD_STR-GP_FREET sy-vline
WA_PLMZD_STR-AOBAR sy-vline
WA_PLMZD_STR-ZEINH sy-vline
WA_PLMZD_STR-DAUER sy-vline
WA_PLMZD_STR-DMENG sy-vline
WA_PLMZD_STR-KNTTP sy-vline
WA_PLMZD_STR-FLGEX sy-vline
WA_PLMZD_STR-VORAB sy-vline
WA_PLMZD_STR-STRECKE sy-vline
WA_PLMZD_STR-STLTY_W sy-vline
WA_PLMZD_STR-STLNR_W sy-vline
WA_PLMZD_STR-STLAL_W sy-vline
WA_PLMZD_STR-KANTE sy-vline
WA_PLMZD_STR-LGORT sy-vline
WA_PLMZD_STR-DISP sy-vline
WA_PLMZD_STR-PRODFLOWID sy-vline
WA_PLMZD_STR-BEIKZ sy-vline
WA_PLMZD_STR-ABLAD sy-vline
WA_PLMZD_STR-WEMPF sy-vline
WA_PLMZD_STR-VALID_TO sy-vline
WA_PLMZD_STR-LOEKZ_INHERITED sy-vline
WA_PLMZD_STR-VERSN sy-vline
WA_PLMZD_STR-VERSN_SOURCE sy-vline
WA_PLMZD_STR-VERSN_SOURCE_ZUONR sy-vline
WA_PLMZD_STR-BOM_VERSN sy-vline
WA_PLMZD_STR-BOM_VERSN_W sy-vline
WA_PLMZD_STR-LOG_COMP sy-vline
WA_PLMZD_STR-DATUB sy-vline
WA_PLMZD_STR-MATNR sy-vline
WA_PLMZD_STR-WERKS sy-vline
WA_PLMZD_STR-MAKTX sy-vline
WA_PLMZD_STR-POSNR sy-vline
WA_PLMZD_STR-MENGE sy-vline
WA_PLMZD_STR-MEINS sy-vline
WA_PLMZD_STR-IUPOS sy-vline
WA_PLMZD_STR-IEBOR sy-vline
WA_PLMZD_STR-BOMAT sy-vline
WA_PLMZD_STR-DBSKZ sy-vline
WA_PLMZD_STR-ARBPL sy-vline
WA_PLMZD_STR-DUMPS sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.