ABAP Select data from SAP table PLMT_AUDIT_AUO_DB_WRK into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP PLMT_AUDIT_AUO_DB_WRK table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to PLMT_AUDIT_AUO_DB_WRK. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the PLMT_AUDIT_AUO_DB_WRK table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_PLMT_AUDIT_AUO_DB_WRK TYPE STANDARD TABLE OF PLMT_AUDIT_AUO_DB_WRK,
      WA_PLMT_AUDIT_AUO_DB_WRK TYPE PLMT_AUDIT_AUO_DB_WRK,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: <PLMT_AUDIT_AUO_DB_WRK> TYPE PLMT_AUDIT_AUO_DB_WRK.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_PLMT_AUDIT_AUO_DB_WRK.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM PLMT_AUDIT_AUO_DB_WRK
  INTO TABLE IT_PLMT_AUDIT_AUO_DB_WRK.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM PLMT_AUDIT_AUO_DB_WRK
*  INTO TABLE @DATA(IT_PLMT_AUDIT_AUO_DB_WRK2).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_PLMT_AUDIT_AUO_DB_WRK INDEX 1 INTO DATA(WA_PLMT_AUDIT_AUO_DB_WRK2).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_PLMT_AUDIT_AUO_DB_WRK ASSIGNING <PLMT_AUDIT_AUO_DB_WRK>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
<PLMT_AUDIT_AUO_DB_WRK>-CLIENT = 1.
<PLMT_AUDIT_AUO_DB_WRK>-GUID = 1.
<PLMT_AUDIT_AUO_DB_WRK>-ORIGINAL_LANGU = 1.
<PLMT_AUDIT_AUO_DB_WRK>-AUDIT_TYPE = 1.
<PLMT_AUDIT_AUO_DB_WRK>-AUTH_GROUP = 1.
ENDLOOP.

LOOP AT IT_PLMT_AUDIT_AUO_DB_WRK INTO WA_PLMT_AUDIT_AUO_DB_WRK.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_PLMT_AUDIT_AUO_DB_WRK-GROUPING, sy-vline,
WA_PLMT_AUDIT_AUO_DB_WRK-SEARCH_FIELD, sy-vline,
WA_PLMT_AUDIT_AUO_DB_WRK-CAUSE, sy-vline,
WA_PLMT_AUDIT_AUO_DB_WRK-UNPLANNED, sy-vline,
WA_PLMT_AUDIT_AUO_DB_WRK-NEXT_AUDIT_DATE, sy-vline,
WA_PLMT_AUDIT_AUO_DB_WRK-NEXT_AUDIT_OBLIG, sy-vline.
ENDLOOP. *Add any further fields from structure WA_PLMT_AUDIT_AUO_DB_WRK you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_PLMT_AUDIT_AUO_DB_WRK TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_PLMT_AUDIT_AUO_DB_WRK INTO WA_PLMT_AUDIT_AUO_DB_WRK. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.

*Conversion exit PLMAM, internal->external for field GUID CALL FUNCTION 'CONVERSION_EXIT_PLMAM_OUTPUT' EXPORTING input = WA_PLMT_AUDIT_AUO_DB_WRK-GUID IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_PLMT_AUDIT_AUO_DB_WRK-GUID.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ISOLA, internal->external for field ORIGINAL_LANGU CALL FUNCTION 'CONVERSION_EXIT_ISOLA_OUTPUT' EXPORTING input = WA_PLMT_AUDIT_AUO_DB_WRK-ORIGINAL_LANGU IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_PLMT_AUDIT_AUO_DB_WRK-ORIGINAL_LANGU.
WRITE:/ 'New Value:', ld_input.

*Conversion exit TSTPS, internal->external for field RELEASED_ON CALL FUNCTION 'CONVERSION_EXIT_TSTPS_OUTPUT' EXPORTING input = WA_PLMT_AUDIT_AUO_DB_WRK-RELEASED_ON IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_PLMT_AUDIT_AUO_DB_WRK-RELEASED_ON.
WRITE:/ 'New Value:', ld_input.

*Conversion exit PLMAM, internal->external for field TEMPLATE_GUID CALL FUNCTION 'CONVERSION_EXIT_PLMAM_OUTPUT' EXPORTING input = WA_PLMT_AUDIT_AUO_DB_WRK-TEMPLATE_GUID IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_PLMT_AUDIT_AUO_DB_WRK-TEMPLATE_GUID.
WRITE:/ 'New Value:', ld_input.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_PLMT_AUDIT_AUO_DB_WRK_STR,
CLIENT TYPE STRING,
GUID TYPE STRING,
ORIGINAL_LANGU TYPE STRING,
AUDIT_TYPE TYPE STRING,
AUTH_GROUP TYPE STRING,
GROUPING TYPE STRING,
SEARCH_FIELD TYPE STRING,
CAUSE TYPE STRING,
UNPLANNED TYPE STRING,
NEXT_AUDIT_DATE TYPE STRING,
NEXT_AUDIT_OBLIG TYPE STRING,
SCORE_RES TYPE STRING,
SCORE_MANUAL TYPE STRING,
SCORE_MAX TYPE STRING,
AUDIT_CALCULATE TYPE STRING,
RESULT_PERCENT TYPE STRING,
MIN_RESULT TYPE STRING,
CLASSIFICATION TYPE STRING,
CLASSIFI_CODE TYPE STRING,
CLASSIFI_MAN TYPE STRING,
OK_NOK TYPE STRING,
CONFIDENTIAL TYPE STRING,
RELEASED_ON TYPE STRING,
RELEASED_BY TYPE STRING,
PROC_STATUS TYPE STRING,
CALC_STATUS TYPE STRING,
CHANGEDDATETIME TYPE STRING,
DUMMY_FMEA_INCL_EEW_PS TYPE STRING,
TEMPLATE_GUID TYPE STRING,
HEADER_FMEA TYPE STRING,
NOREC_FLAG TYPE STRING,END OF T_EKKO_STR. DATA: WA_PLMT_AUDIT_AUO_DB_WRK_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_PLMT_AUDIT_AUO_DB_WRK_STR-CLIENT sy-vline
WA_PLMT_AUDIT_AUO_DB_WRK_STR-GUID sy-vline
WA_PLMT_AUDIT_AUO_DB_WRK_STR-ORIGINAL_LANGU sy-vline
WA_PLMT_AUDIT_AUO_DB_WRK_STR-AUDIT_TYPE sy-vline
WA_PLMT_AUDIT_AUO_DB_WRK_STR-AUTH_GROUP sy-vline
WA_PLMT_AUDIT_AUO_DB_WRK_STR-GROUPING sy-vline
WA_PLMT_AUDIT_AUO_DB_WRK_STR-SEARCH_FIELD sy-vline
WA_PLMT_AUDIT_AUO_DB_WRK_STR-CAUSE sy-vline
WA_PLMT_AUDIT_AUO_DB_WRK_STR-UNPLANNED sy-vline
WA_PLMT_AUDIT_AUO_DB_WRK_STR-NEXT_AUDIT_DATE sy-vline
WA_PLMT_AUDIT_AUO_DB_WRK_STR-NEXT_AUDIT_OBLIG sy-vline
WA_PLMT_AUDIT_AUO_DB_WRK_STR-SCORE_RES sy-vline
WA_PLMT_AUDIT_AUO_DB_WRK_STR-SCORE_MANUAL sy-vline
WA_PLMT_AUDIT_AUO_DB_WRK_STR-SCORE_MAX sy-vline
WA_PLMT_AUDIT_AUO_DB_WRK_STR-AUDIT_CALCULATE sy-vline
WA_PLMT_AUDIT_AUO_DB_WRK_STR-RESULT_PERCENT sy-vline
WA_PLMT_AUDIT_AUO_DB_WRK_STR-MIN_RESULT sy-vline
WA_PLMT_AUDIT_AUO_DB_WRK_STR-CLASSIFICATION sy-vline
WA_PLMT_AUDIT_AUO_DB_WRK_STR-CLASSIFI_CODE sy-vline
WA_PLMT_AUDIT_AUO_DB_WRK_STR-CLASSIFI_MAN sy-vline
WA_PLMT_AUDIT_AUO_DB_WRK_STR-OK_NOK sy-vline
WA_PLMT_AUDIT_AUO_DB_WRK_STR-CONFIDENTIAL sy-vline
WA_PLMT_AUDIT_AUO_DB_WRK_STR-RELEASED_ON sy-vline
WA_PLMT_AUDIT_AUO_DB_WRK_STR-RELEASED_BY sy-vline
WA_PLMT_AUDIT_AUO_DB_WRK_STR-PROC_STATUS sy-vline
WA_PLMT_AUDIT_AUO_DB_WRK_STR-CALC_STATUS sy-vline
WA_PLMT_AUDIT_AUO_DB_WRK_STR-CHANGEDDATETIME sy-vline
WA_PLMT_AUDIT_AUO_DB_WRK_STR-DUMMY_FMEA_INCL_EEW_PS sy-vline
WA_PLMT_AUDIT_AUO_DB_WRK_STR-TEMPLATE_GUID sy-vline
WA_PLMT_AUDIT_AUO_DB_WRK_STR-HEADER_FMEA sy-vline
WA_PLMT_AUDIT_AUO_DB_WRK_STR-NOREC_FLAG sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.