ABAP Select data from SAP table PLMLB_BOMMAT07V2 into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP PLMLB_BOMMAT07V2 table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to PLMLB_BOMMAT07V2. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the PLMLB_BOMMAT07V2 table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_PLMLB_BOMMAT07V2 TYPE STANDARD TABLE OF PLMLB_BOMMAT07V2,
      WA_PLMLB_BOMMAT07V2 TYPE PLMLB_BOMMAT07V2,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: <PLMLB_BOMMAT07V2> TYPE PLMLB_BOMMAT07V2.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_PLMLB_BOMMAT07V2.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM PLMLB_BOMMAT07V2
  INTO TABLE IT_PLMLB_BOMMAT07V2.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM PLMLB_BOMMAT07V2
*  INTO TABLE @DATA(IT_PLMLB_BOMMAT07V22).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_PLMLB_BOMMAT07V2 INDEX 1 INTO DATA(WA_PLMLB_BOMMAT07V22).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_PLMLB_BOMMAT07V2 ASSIGNING <PLMLB_BOMMAT07V2>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
<PLMLB_BOMMAT07V2>-EDIDC = 1.
<PLMLB_BOMMAT07V2>-MANDT = 1.
<PLMLB_BOMMAT07V2>-DOCNUM = 1.
<PLMLB_BOMMAT07V2>-DOCREL = 1.
<PLMLB_BOMMAT07V2>-STATUS = 1.
ENDLOOP.

LOOP AT IT_PLMLB_BOMMAT07V2 INTO WA_PLMLB_BOMMAT07V2.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_PLMLB_BOMMAT07V2-DOCTYP, sy-vline,
WA_PLMLB_BOMMAT07V2-DIRECT, sy-vline,
WA_PLMLB_BOMMAT07V2-RCVPOR, sy-vline,
WA_PLMLB_BOMMAT07V2-RCVPRT, sy-vline,
WA_PLMLB_BOMMAT07V2-RCVPRN, sy-vline,
WA_PLMLB_BOMMAT07V2-RCVSAD, sy-vline.
ENDLOOP. *Add any further fields from structure WA_PLMLB_BOMMAT07V2 you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_PLMLB_BOMMAT07V2 TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_PLMLB_BOMMAT07V2 INTO WA_PLMLB_BOMMAT07V2. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.

*Conversion exit ALPHA, internal->external for field RCVPRN CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_PLMLB_BOMMAT07V2-RCVPRN IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_PLMLB_BOMMAT07V2-RCVPRN.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field SNDPRN CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_PLMLB_BOMMAT07V2-SNDPRN IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_PLMLB_BOMMAT07V2-SNDPRN.
WRITE:/ 'New Value:', ld_input.

*Conversion exit EDIPV, internal->external for field RCVPFC CALL FUNCTION 'CONVERSION_EXIT_EDIPV_OUTPUT' EXPORTING input = WA_PLMLB_BOMMAT07V2-RCVPFC IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_PLMLB_BOMMAT07V2-RCVPFC.
WRITE:/ 'New Value:', ld_input.

*Conversion exit EDIPV, internal->external for field SNDPFC CALL FUNCTION 'CONVERSION_EXIT_EDIPV_OUTPUT' EXPORTING input = WA_PLMLB_BOMMAT07V2-SNDPFC IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_PLMLB_BOMMAT07V2-SNDPFC.
WRITE:/ 'New Value:', ld_input.

*Conversion exit NUMCV, internal->external for field STLNR CALL FUNCTION 'CONVERSION_EXIT_NUMCV_OUTPUT' EXPORTING input = WA_PLMLB_BOMMAT07V2-STLNR IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_PLMLB_BOMMAT07V2-STLNR.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field AENRL CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_PLMLB_BOMMAT07V2-AENRL IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_PLMLB_BOMMAT07V2-AENRL.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ISOLA, internal->external for field TDSPRAS CALL FUNCTION 'CONVERSION_EXIT_ISOLA_OUTPUT' EXPORTING input = WA_PLMLB_BOMMAT07V2-TDSPRAS IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_PLMLB_BOMMAT07V2-TDSPRAS.
WRITE:/ 'New Value:', ld_input.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_PLMLB_BOMMAT07V2_STR,
EDIDC TYPE STRING,
MANDT TYPE STRING,
DOCNUM TYPE STRING,
DOCREL TYPE STRING,
STATUS TYPE STRING,
DOCTYP TYPE STRING,
DIRECT TYPE STRING,
RCVPOR TYPE STRING,
RCVPRT TYPE STRING,
RCVPRN TYPE STRING,
RCVSAD TYPE STRING,
RCVSMN TYPE STRING,
RCVSNA TYPE STRING,
RCVSCA TYPE STRING,
RCVSDF TYPE STRING,
RCVSLF TYPE STRING,
RCVLAD TYPE STRING,
STD TYPE STRING,
STDVRS TYPE STRING,
STDMES TYPE STRING,
MESCOD TYPE STRING,
MESFCT TYPE STRING,
OUTMOD TYPE STRING,
TEST TYPE STRING,
SNDPOR TYPE STRING,
SNDPRT TYPE STRING,
SNDPRN TYPE STRING,
SNDSAD TYPE STRING,
SNDSMN TYPE STRING,
SNDSNA TYPE STRING,
SNDSCA TYPE STRING,
SNDSDF TYPE STRING,
SNDSLF TYPE STRING,
SNDLAD TYPE STRING,
REFINT TYPE STRING,
REFGRP TYPE STRING,
REFMES TYPE STRING,
ARCKEY TYPE STRING,
CREDAT TYPE STRING,
CRETIM TYPE STRING,
MESTYP TYPE STRING,
IDOCTP TYPE STRING,
CIMTYP TYPE STRING,
RCVPFC TYPE STRING,
SNDPFC TYPE STRING,
SERIAL TYPE STRING,
EXPRSS TYPE STRING,
UPDDAT TYPE STRING,
UPDTIM TYPE STRING,
MAXSEGNUM TYPE STRING,
E1STZUM TYPE STRING,
MSGFN TYPE STRING,
STLTY TYPE STRING,
STLNR TYPE STRING,
STLAN TYPE STRING,
EXSTL TYPE STRING,
ALTST TYPE STRING,
VARST TYPE STRING,
KBAUS TYPE STRING,
LTXSP TYPE STRING,
STLBE TYPE STRING,
ZTEXT TYPE STRING,
AENRL TYPE STRING,
STLDT TYPE STRING,
STLTM TYPE STRING,
LTXSP_ISO TYPE STRING,
EXSTL_C TYPE STRING,
E1SZUTH TYPE STRING,
MSGFN TYPE STRING,
TDNAME TYPE STRING,
TDID TYPE STRING,
TDSPRAS TYPE STRING,
TDSPRAS_ISO TYPE STRING,
E1SZUTL TYPE STRING,
E1MASTM TYPE STRING,
E1STKOM TYPE STRING,
E1STASM TYPE STRING,
E1STPOM TYPE STRING,
E1UPSLINK TYPE STRING,
UPSNAM TYPE STRING,
ORGNAM TYPE STRING,
MESTYP TYPE STRING,
OBJID TYPE STRING,
OBJVAL TYPE STRING,END OF T_EKKO_STR. DATA: WA_PLMLB_BOMMAT07V2_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_PLMLB_BOMMAT07V2_STR-EDIDC sy-vline
WA_PLMLB_BOMMAT07V2_STR-MANDT sy-vline
WA_PLMLB_BOMMAT07V2_STR-DOCNUM sy-vline
WA_PLMLB_BOMMAT07V2_STR-DOCREL sy-vline
WA_PLMLB_BOMMAT07V2_STR-STATUS sy-vline
WA_PLMLB_BOMMAT07V2_STR-DOCTYP sy-vline
WA_PLMLB_BOMMAT07V2_STR-DIRECT sy-vline
WA_PLMLB_BOMMAT07V2_STR-RCVPOR sy-vline
WA_PLMLB_BOMMAT07V2_STR-RCVPRT sy-vline
WA_PLMLB_BOMMAT07V2_STR-RCVPRN sy-vline
WA_PLMLB_BOMMAT07V2_STR-RCVSAD sy-vline
WA_PLMLB_BOMMAT07V2_STR-RCVSMN sy-vline
WA_PLMLB_BOMMAT07V2_STR-RCVSNA sy-vline
WA_PLMLB_BOMMAT07V2_STR-RCVSCA sy-vline
WA_PLMLB_BOMMAT07V2_STR-RCVSDF sy-vline
WA_PLMLB_BOMMAT07V2_STR-RCVSLF sy-vline
WA_PLMLB_BOMMAT07V2_STR-RCVLAD sy-vline
WA_PLMLB_BOMMAT07V2_STR-STD sy-vline
WA_PLMLB_BOMMAT07V2_STR-STDVRS sy-vline
WA_PLMLB_BOMMAT07V2_STR-STDMES sy-vline
WA_PLMLB_BOMMAT07V2_STR-MESCOD sy-vline
WA_PLMLB_BOMMAT07V2_STR-MESFCT sy-vline
WA_PLMLB_BOMMAT07V2_STR-OUTMOD sy-vline
WA_PLMLB_BOMMAT07V2_STR-TEST sy-vline
WA_PLMLB_BOMMAT07V2_STR-SNDPOR sy-vline
WA_PLMLB_BOMMAT07V2_STR-SNDPRT sy-vline
WA_PLMLB_BOMMAT07V2_STR-SNDPRN sy-vline
WA_PLMLB_BOMMAT07V2_STR-SNDSAD sy-vline
WA_PLMLB_BOMMAT07V2_STR-SNDSMN sy-vline
WA_PLMLB_BOMMAT07V2_STR-SNDSNA sy-vline
WA_PLMLB_BOMMAT07V2_STR-SNDSCA sy-vline
WA_PLMLB_BOMMAT07V2_STR-SNDSDF sy-vline
WA_PLMLB_BOMMAT07V2_STR-SNDSLF sy-vline
WA_PLMLB_BOMMAT07V2_STR-SNDLAD sy-vline
WA_PLMLB_BOMMAT07V2_STR-REFINT sy-vline
WA_PLMLB_BOMMAT07V2_STR-REFGRP sy-vline
WA_PLMLB_BOMMAT07V2_STR-REFMES sy-vline
WA_PLMLB_BOMMAT07V2_STR-ARCKEY sy-vline
WA_PLMLB_BOMMAT07V2_STR-CREDAT sy-vline
WA_PLMLB_BOMMAT07V2_STR-CRETIM sy-vline
WA_PLMLB_BOMMAT07V2_STR-MESTYP sy-vline
WA_PLMLB_BOMMAT07V2_STR-IDOCTP sy-vline
WA_PLMLB_BOMMAT07V2_STR-CIMTYP sy-vline
WA_PLMLB_BOMMAT07V2_STR-RCVPFC sy-vline
WA_PLMLB_BOMMAT07V2_STR-SNDPFC sy-vline
WA_PLMLB_BOMMAT07V2_STR-SERIAL sy-vline
WA_PLMLB_BOMMAT07V2_STR-EXPRSS sy-vline
WA_PLMLB_BOMMAT07V2_STR-UPDDAT sy-vline
WA_PLMLB_BOMMAT07V2_STR-UPDTIM sy-vline
WA_PLMLB_BOMMAT07V2_STR-MAXSEGNUM sy-vline
WA_PLMLB_BOMMAT07V2_STR-E1STZUM sy-vline
WA_PLMLB_BOMMAT07V2_STR-MSGFN sy-vline
WA_PLMLB_BOMMAT07V2_STR-STLTY sy-vline
WA_PLMLB_BOMMAT07V2_STR-STLNR sy-vline
WA_PLMLB_BOMMAT07V2_STR-STLAN sy-vline
WA_PLMLB_BOMMAT07V2_STR-EXSTL sy-vline
WA_PLMLB_BOMMAT07V2_STR-ALTST sy-vline
WA_PLMLB_BOMMAT07V2_STR-VARST sy-vline
WA_PLMLB_BOMMAT07V2_STR-KBAUS sy-vline
WA_PLMLB_BOMMAT07V2_STR-LTXSP sy-vline
WA_PLMLB_BOMMAT07V2_STR-STLBE sy-vline
WA_PLMLB_BOMMAT07V2_STR-ZTEXT sy-vline
WA_PLMLB_BOMMAT07V2_STR-AENRL sy-vline
WA_PLMLB_BOMMAT07V2_STR-STLDT sy-vline
WA_PLMLB_BOMMAT07V2_STR-STLTM sy-vline
WA_PLMLB_BOMMAT07V2_STR-LTXSP_ISO sy-vline
WA_PLMLB_BOMMAT07V2_STR-EXSTL_C sy-vline
WA_PLMLB_BOMMAT07V2_STR-E1SZUTH sy-vline
WA_PLMLB_BOMMAT07V2_STR-MSGFN sy-vline
WA_PLMLB_BOMMAT07V2_STR-TDNAME sy-vline
WA_PLMLB_BOMMAT07V2_STR-TDID sy-vline
WA_PLMLB_BOMMAT07V2_STR-TDSPRAS sy-vline
WA_PLMLB_BOMMAT07V2_STR-TDSPRAS_ISO sy-vline
WA_PLMLB_BOMMAT07V2_STR-E1SZUTL sy-vline
WA_PLMLB_BOMMAT07V2_STR-E1MASTM sy-vline
WA_PLMLB_BOMMAT07V2_STR-E1STKOM sy-vline
WA_PLMLB_BOMMAT07V2_STR-E1STASM sy-vline
WA_PLMLB_BOMMAT07V2_STR-E1STPOM sy-vline
WA_PLMLB_BOMMAT07V2_STR-E1UPSLINK sy-vline
WA_PLMLB_BOMMAT07V2_STR-UPSNAM sy-vline
WA_PLMLB_BOMMAT07V2_STR-ORGNAM sy-vline
WA_PLMLB_BOMMAT07V2_STR-MESTYP sy-vline
WA_PLMLB_BOMMAT07V2_STR-OBJID sy-vline
WA_PLMLB_BOMMAT07V2_STR-OBJVAL sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.