ABAP Select data from SAP table PLMLB_BOMMAT05 into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP PLMLB_BOMMAT05 table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to PLMLB_BOMMAT05. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the PLMLB_BOMMAT05 table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_PLMLB_BOMMAT05 TYPE STANDARD TABLE OF PLMLB_BOMMAT05,
      WA_PLMLB_BOMMAT05 TYPE PLMLB_BOMMAT05,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: <PLMLB_BOMMAT05> TYPE PLMLB_BOMMAT05.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_PLMLB_BOMMAT05.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM PLMLB_BOMMAT05
  INTO TABLE IT_PLMLB_BOMMAT05.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM PLMLB_BOMMAT05
*  INTO TABLE @DATA(IT_PLMLB_BOMMAT052).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_PLMLB_BOMMAT05 INDEX 1 INTO DATA(WA_PLMLB_BOMMAT052).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_PLMLB_BOMMAT05 ASSIGNING <PLMLB_BOMMAT05>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
<PLMLB_BOMMAT05>-EDIDC = 1.
<PLMLB_BOMMAT05>-MANDT = 1.
<PLMLB_BOMMAT05>-DOCNUM = 1.
<PLMLB_BOMMAT05>-DOCREL = 1.
<PLMLB_BOMMAT05>-STATUS = 1.
ENDLOOP.

LOOP AT IT_PLMLB_BOMMAT05 INTO WA_PLMLB_BOMMAT05.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_PLMLB_BOMMAT05-DOCTYP, sy-vline,
WA_PLMLB_BOMMAT05-DIRECT, sy-vline,
WA_PLMLB_BOMMAT05-RCVPOR, sy-vline,
WA_PLMLB_BOMMAT05-RCVPRT, sy-vline,
WA_PLMLB_BOMMAT05-RCVPRN, sy-vline,
WA_PLMLB_BOMMAT05-RCVSAD, sy-vline.
ENDLOOP. *Add any further fields from structure WA_PLMLB_BOMMAT05 you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_PLMLB_BOMMAT05 TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_PLMLB_BOMMAT05 INTO WA_PLMLB_BOMMAT05. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.

*Conversion exit ALPHA, internal->external for field RCVPRN CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_PLMLB_BOMMAT05-RCVPRN IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_PLMLB_BOMMAT05-RCVPRN.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field SNDPRN CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_PLMLB_BOMMAT05-SNDPRN IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_PLMLB_BOMMAT05-SNDPRN.
WRITE:/ 'New Value:', ld_input.

*Conversion exit EDIPV, internal->external for field RCVPFC CALL FUNCTION 'CONVERSION_EXIT_EDIPV_OUTPUT' EXPORTING input = WA_PLMLB_BOMMAT05-RCVPFC IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_PLMLB_BOMMAT05-RCVPFC.
WRITE:/ 'New Value:', ld_input.

*Conversion exit EDIPV, internal->external for field SNDPFC CALL FUNCTION 'CONVERSION_EXIT_EDIPV_OUTPUT' EXPORTING input = WA_PLMLB_BOMMAT05-SNDPFC IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_PLMLB_BOMMAT05-SNDPFC.
WRITE:/ 'New Value:', ld_input.

*Conversion exit NUMCV, internal->external for field STLNR CALL FUNCTION 'CONVERSION_EXIT_NUMCV_OUTPUT' EXPORTING input = WA_PLMLB_BOMMAT05-STLNR IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_PLMLB_BOMMAT05-STLNR.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field AENRL CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_PLMLB_BOMMAT05-AENRL IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_PLMLB_BOMMAT05-AENRL.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ISOLA, internal->external for field TDSPRAS CALL FUNCTION 'CONVERSION_EXIT_ISOLA_OUTPUT' EXPORTING input = WA_PLMLB_BOMMAT05-TDSPRAS IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_PLMLB_BOMMAT05-TDSPRAS.
WRITE:/ 'New Value:', ld_input.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_PLMLB_BOMMAT05_STR,
EDIDC TYPE STRING,
MANDT TYPE STRING,
DOCNUM TYPE STRING,
DOCREL TYPE STRING,
STATUS TYPE STRING,
DOCTYP TYPE STRING,
DIRECT TYPE STRING,
RCVPOR TYPE STRING,
RCVPRT TYPE STRING,
RCVPRN TYPE STRING,
RCVSAD TYPE STRING,
RCVSMN TYPE STRING,
RCVSNA TYPE STRING,
RCVSCA TYPE STRING,
RCVSDF TYPE STRING,
RCVSLF TYPE STRING,
RCVLAD TYPE STRING,
STD TYPE STRING,
STDVRS TYPE STRING,
STDMES TYPE STRING,
MESCOD TYPE STRING,
MESFCT TYPE STRING,
OUTMOD TYPE STRING,
TEST TYPE STRING,
SNDPOR TYPE STRING,
SNDPRT TYPE STRING,
SNDPRN TYPE STRING,
SNDSAD TYPE STRING,
SNDSMN TYPE STRING,
SNDSNA TYPE STRING,
SNDSCA TYPE STRING,
SNDSDF TYPE STRING,
SNDSLF TYPE STRING,
SNDLAD TYPE STRING,
REFINT TYPE STRING,
REFGRP TYPE STRING,
REFMES TYPE STRING,
ARCKEY TYPE STRING,
CREDAT TYPE STRING,
CRETIM TYPE STRING,
MESTYP TYPE STRING,
IDOCTP TYPE STRING,
CIMTYP TYPE STRING,
RCVPFC TYPE STRING,
SNDPFC TYPE STRING,
SERIAL TYPE STRING,
EXPRSS TYPE STRING,
UPDDAT TYPE STRING,
UPDTIM TYPE STRING,
MAXSEGNUM TYPE STRING,
E1STZUM TYPE STRING,
MSGFN TYPE STRING,
STLTY TYPE STRING,
STLNR TYPE STRING,
STLAN TYPE STRING,
EXSTL TYPE STRING,
ALTST TYPE STRING,
VARST TYPE STRING,
KBAUS TYPE STRING,
LTXSP TYPE STRING,
STLBE TYPE STRING,
ZTEXT TYPE STRING,
AENRL TYPE STRING,
STLDT TYPE STRING,
STLTM TYPE STRING,
LTXSP_ISO TYPE STRING,
EXSTL_C TYPE STRING,
E1SZUTH TYPE STRING,
MSGFN TYPE STRING,
TDNAME TYPE STRING,
TDID TYPE STRING,
TDSPRAS TYPE STRING,
TDSPRAS_ISO TYPE STRING,
E1SZUTL TYPE STRING,
E1MASTM TYPE STRING,
E1STKOM TYPE STRING,
E1STASM TYPE STRING,
E1STPOM TYPE STRING,
E1UPSLINK TYPE STRING,
UPSNAM TYPE STRING,
ORGNAM TYPE STRING,
MESTYP TYPE STRING,
OBJID TYPE STRING,
OBJVAL TYPE STRING,END OF T_EKKO_STR. DATA: WA_PLMLB_BOMMAT05_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_PLMLB_BOMMAT05_STR-EDIDC sy-vline
WA_PLMLB_BOMMAT05_STR-MANDT sy-vline
WA_PLMLB_BOMMAT05_STR-DOCNUM sy-vline
WA_PLMLB_BOMMAT05_STR-DOCREL sy-vline
WA_PLMLB_BOMMAT05_STR-STATUS sy-vline
WA_PLMLB_BOMMAT05_STR-DOCTYP sy-vline
WA_PLMLB_BOMMAT05_STR-DIRECT sy-vline
WA_PLMLB_BOMMAT05_STR-RCVPOR sy-vline
WA_PLMLB_BOMMAT05_STR-RCVPRT sy-vline
WA_PLMLB_BOMMAT05_STR-RCVPRN sy-vline
WA_PLMLB_BOMMAT05_STR-RCVSAD sy-vline
WA_PLMLB_BOMMAT05_STR-RCVSMN sy-vline
WA_PLMLB_BOMMAT05_STR-RCVSNA sy-vline
WA_PLMLB_BOMMAT05_STR-RCVSCA sy-vline
WA_PLMLB_BOMMAT05_STR-RCVSDF sy-vline
WA_PLMLB_BOMMAT05_STR-RCVSLF sy-vline
WA_PLMLB_BOMMAT05_STR-RCVLAD sy-vline
WA_PLMLB_BOMMAT05_STR-STD sy-vline
WA_PLMLB_BOMMAT05_STR-STDVRS sy-vline
WA_PLMLB_BOMMAT05_STR-STDMES sy-vline
WA_PLMLB_BOMMAT05_STR-MESCOD sy-vline
WA_PLMLB_BOMMAT05_STR-MESFCT sy-vline
WA_PLMLB_BOMMAT05_STR-OUTMOD sy-vline
WA_PLMLB_BOMMAT05_STR-TEST sy-vline
WA_PLMLB_BOMMAT05_STR-SNDPOR sy-vline
WA_PLMLB_BOMMAT05_STR-SNDPRT sy-vline
WA_PLMLB_BOMMAT05_STR-SNDPRN sy-vline
WA_PLMLB_BOMMAT05_STR-SNDSAD sy-vline
WA_PLMLB_BOMMAT05_STR-SNDSMN sy-vline
WA_PLMLB_BOMMAT05_STR-SNDSNA sy-vline
WA_PLMLB_BOMMAT05_STR-SNDSCA sy-vline
WA_PLMLB_BOMMAT05_STR-SNDSDF sy-vline
WA_PLMLB_BOMMAT05_STR-SNDSLF sy-vline
WA_PLMLB_BOMMAT05_STR-SNDLAD sy-vline
WA_PLMLB_BOMMAT05_STR-REFINT sy-vline
WA_PLMLB_BOMMAT05_STR-REFGRP sy-vline
WA_PLMLB_BOMMAT05_STR-REFMES sy-vline
WA_PLMLB_BOMMAT05_STR-ARCKEY sy-vline
WA_PLMLB_BOMMAT05_STR-CREDAT sy-vline
WA_PLMLB_BOMMAT05_STR-CRETIM sy-vline
WA_PLMLB_BOMMAT05_STR-MESTYP sy-vline
WA_PLMLB_BOMMAT05_STR-IDOCTP sy-vline
WA_PLMLB_BOMMAT05_STR-CIMTYP sy-vline
WA_PLMLB_BOMMAT05_STR-RCVPFC sy-vline
WA_PLMLB_BOMMAT05_STR-SNDPFC sy-vline
WA_PLMLB_BOMMAT05_STR-SERIAL sy-vline
WA_PLMLB_BOMMAT05_STR-EXPRSS sy-vline
WA_PLMLB_BOMMAT05_STR-UPDDAT sy-vline
WA_PLMLB_BOMMAT05_STR-UPDTIM sy-vline
WA_PLMLB_BOMMAT05_STR-MAXSEGNUM sy-vline
WA_PLMLB_BOMMAT05_STR-E1STZUM sy-vline
WA_PLMLB_BOMMAT05_STR-MSGFN sy-vline
WA_PLMLB_BOMMAT05_STR-STLTY sy-vline
WA_PLMLB_BOMMAT05_STR-STLNR sy-vline
WA_PLMLB_BOMMAT05_STR-STLAN sy-vline
WA_PLMLB_BOMMAT05_STR-EXSTL sy-vline
WA_PLMLB_BOMMAT05_STR-ALTST sy-vline
WA_PLMLB_BOMMAT05_STR-VARST sy-vline
WA_PLMLB_BOMMAT05_STR-KBAUS sy-vline
WA_PLMLB_BOMMAT05_STR-LTXSP sy-vline
WA_PLMLB_BOMMAT05_STR-STLBE sy-vline
WA_PLMLB_BOMMAT05_STR-ZTEXT sy-vline
WA_PLMLB_BOMMAT05_STR-AENRL sy-vline
WA_PLMLB_BOMMAT05_STR-STLDT sy-vline
WA_PLMLB_BOMMAT05_STR-STLTM sy-vline
WA_PLMLB_BOMMAT05_STR-LTXSP_ISO sy-vline
WA_PLMLB_BOMMAT05_STR-EXSTL_C sy-vline
WA_PLMLB_BOMMAT05_STR-E1SZUTH sy-vline
WA_PLMLB_BOMMAT05_STR-MSGFN sy-vline
WA_PLMLB_BOMMAT05_STR-TDNAME sy-vline
WA_PLMLB_BOMMAT05_STR-TDID sy-vline
WA_PLMLB_BOMMAT05_STR-TDSPRAS sy-vline
WA_PLMLB_BOMMAT05_STR-TDSPRAS_ISO sy-vline
WA_PLMLB_BOMMAT05_STR-E1SZUTL sy-vline
WA_PLMLB_BOMMAT05_STR-E1MASTM sy-vline
WA_PLMLB_BOMMAT05_STR-E1STKOM sy-vline
WA_PLMLB_BOMMAT05_STR-E1STASM sy-vline
WA_PLMLB_BOMMAT05_STR-E1STPOM sy-vline
WA_PLMLB_BOMMAT05_STR-E1UPSLINK sy-vline
WA_PLMLB_BOMMAT05_STR-UPSNAM sy-vline
WA_PLMLB_BOMMAT05_STR-ORGNAM sy-vline
WA_PLMLB_BOMMAT05_STR-MESTYP sy-vline
WA_PLMLB_BOMMAT05_STR-OBJID sy-vline
WA_PLMLB_BOMMAT05_STR-OBJVAL sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.